Fluke Ti105 a3001 FC iFlex® Kit
Key features
- Fluke Connect ™ compatible – the largest network for wirelessly enabled tools. Take advantage of the benefits of Fluke Connect® by sharing inspection results instantly, with any team member, at any time.
- Rugged, lightweight, point-and-shoot focus free thermal camera
- One-handed, easy-to-use user interface
- Included SmartView® and SmartView Mobile App Analysis and Reporting Software
The 3000 FC Wireless Multimeter offers:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:
- One (1) true-RMS flexible current meter
- One (1) iFlex i2500-10 flexible current probe
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
- Magnetic hanging strap
Product overview: Fluke Ti105 a3001 FC iFlex® Kit
Industrial and commercial professionals can save time and money by identifying problems before they become costly failures with the Ti105 a3001 FC iFlex® Kit. Connect the a3001 FC iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on your 3000 FC DMM. The a3001 FC iFlex® module allows you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. The Ti105 infrared camera comes standard with IR Fusion® Technology - the blending of digital and infrared images into a single image making precise documentation quick and easy. Upload all your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.
Simplify and streamline your reporting with our easy to use SmartView® software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite.
Specifications: Fluke Ti105 a3001 FC iFlex® Kit
Detailed Specifications | |
IR resolution (FPA size) | 160 x 120 FPA Uncooled Microbolometer |
Spectral band | 7.5 µm to 14 µm (long wave) |
Capture or refresh rate | 30 Hz version |
NETD (thermal sensitivity) | ≤ 0.10°C at 30°C target temp (100 mK) |
FOV (field of view) | 22.5° H x 31° V |
IFOV (spatial resolution) | 3.39 mRad |
Temperature measurement range (not calibrated below -10°C) | -20°C to + 250°C (-4°F to 482°F) |
Temperature measurement accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) |
Focus mechanism | Focus-free 1.2 m (4 ft) and beyond |
IR Fusion® technology | PIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible |
Fluke Connect compatibility | Yes (where available) |
Color alarms | - |
Standard palettes | Blue-red, ironbow, grayscale and amber |
Ultra Contrast™ palettes | - |
Hot/cold markers | - |
User definable spot markers | In SmartView® only |
Centerpoint | Yes |
Centerbox (MIN/AVG/MAX) | - |
Level and span control | Manual and auto |
Minimum span in auto mode | 5°C |
Minimum span in manual mode | 2.5°C |
Minimum IR focus distance | 122 cm (48 in) |
Weight | 0.726 kg (1.6 lb) |
Size | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
LCD display | 3.5 inch diagonal (portrait format) |
Visible camera | 2 megapixel industrial-grade |
Minimum parallax | ~122 cm (48 in) |
IR-PhotoNotes™ annotation system | - |
Laser pointer | Yes |
Torch | Yes |
Electronic (cardinal) compass | - |
Emissivity correction | Yes |
Transmission correction | - |
Background (reflected) compensation | Yes |
Voice annotation (audio) | - |
Multi-mode video output | - |
Multi-mode video recording (standard AVI with MPEG encoding) | - |
Multi-mode video recording (radiometric .IS3) | - |
Memory review | Thumbnail review |
Battery (field-replaceable, rechargeable) | One |
Battery life | 4+ hours (each)* |
External battery charging base | Optional (accessory) |
Charging power supply | Yes |
Drop test | 2 meter (6.5 feet) |
Ingress protection (IP) rating (IEC 60529) | IP 54 |
Recommended calibration cycle | Two-years |
Multifunction card reader | - |
Memory storage | 2 GB SD memory card |
Direct download capability | Mini USB download direct to PC |
Operating temperature range | -10°C to +50°C (14°F to 122°F) |
Storage temperature range | -20°C to +50°C (-4°F to 122°F) |
Operating humidity | Operating and storage 10% to 95%, non-condensing |
Vibration and shock | 2G, IEC 68-2-26 and 25G, IEC 68-2-29 |
Safety standards | IEC 61010-1: Cat None, Pollution Degree 2 |
C Tick | IEC/EN 61326-1 |
EMI, RFI, EMC | EN61326-1; FCC Part 5 |
User manuals | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian |
Standard warranty period | Two-years |
Extended warranty and service plans | Yes |
*Assumes 50% brightness of LCD |
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).
Fluke 3000 FC Series Wireless Multimeter
AC Voltage | |||
Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | ||
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | |||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
mV | Range / resolution | 600.0 mV / 0.1 mV | |
Accuracy | 0.09% + 2 | ||
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy | 0.09% + 2 0.15% + 2 | ||
))) | Range / resolution | 600 Ω / 1 Ω | |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | ||
Diode test | Range / resolution | 2.000 V / 0.001 V | |
Accuracy | 1% + 2 | ||
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF | |
Accuracy | 1.2% + 2 10% typical | ||
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||
AC and DC Current | |||
mA AC (45 Hz to 1 kHz) | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | |
Accuracy | 1.5% + 3 | ||
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | |
Accuracy | 0.5% + 3 | ||
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | |||
Frequency | |||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | ||
Accuracy1 | 0.1% + 1 | ||
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||
Input Characteristics | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Open Circuit Test Voltage | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 VDC < 0.9 VDC | ||
Typical short circuit current | < 350 mA | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 VDC | ||
Typical short circuit current | < 1.1 mA | ||
mA Function | |||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording Accuracy | |||
DC functions | ±12 counts for changes > 350 mS in duration. | ||
AC functions | ±40 counts for changes > 900 mS in duration. | ||
General Specifications | |||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||
Display (LCD) | Update rate | 4/sec | |
Volts, amps, ohms | 6000 counts | ||
Frequency | 10,000 counts | ||
Capacitance | 1,000 counts | ||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||
Battery life | 250 hours minimum | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | Open air, unobstructed | Up to 20m | |
Obstructed, sheetrock wall | Up to 6.5m | ||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | ||
Temperature | Operating | -10°C to 50°C | |
Storage | -40°C to 60°C | ||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||
Altitude | Operating | 2,000 m | |
Storage | 12,000 m | ||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | ||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 | ||
Certifications | CSA, FCC, CE | ||
Ingress Protection (IP) rating | IP54 | ||
Pollution Degree | 2 | ||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
Weight | 340 g (12 oz) | ||
Warranty | Three years | ||
Not compatible with Fluke CNX test tools |
Fluke a3001 FC Wireless iFlex AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ± 5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |
LCD w/backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Models: Fluke Ti105 a3001 FC iFlex® Kit
Includes:
Fluke 105 Infrared Camera
- AC power adapter
- Lithium ion smart battery (1)
- USB cable
- SD memory card
- Fluke Connect™ WiFi SD Card
- Hard carrying case
- Soft transport bag
- Adjustable hand strap (left- or right-handed use)
- Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
- SmartView® software
- Warranty registration card
Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)
- One (1) a3001 FC Module with two (2) AA batteries (installed)
- One (1) iFlex 10" coil
- One (1) magnet/strap
- TL175 Test Leads (1 pair)
- AC175 Alligator Clips (1 pair)
- C3003 3-compartment soft case
- Information pack
Manuals + resources: Fluke Ti105 a3001 FC iFlex® Kit
- Saving measurements with AutoRecord™ measurements
- How to email a measurement using the Fluke Connect app
- What is Fluke Connect®
- Connecting multiple tools at the same time with Fluke Connect®
- Performing predictive maintenance with Fluke Connect™
- Connecting the T3000 FC with the Fluke Connect™ app
- Measuring from a safe distance using the Fluke Connect™ app
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Viewing and graphing three phase measurements
- Measurement history in one place using EquipmentLog™ history
- How to create an equipment baseline with EquipmentLog™ history
- Connecting a thermal imager to your iPhone