Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V TRMS Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 TRMS Digital Multimeter with temperature readings
- Fluke 117 Electricians Multimeter with Non-Contact voltage
- Fluke 115 Digital Multimeter for Technicians
- Fluke 177 True-RMS Digital Multimeter with display backlight
- Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
- Fluke 28 II TRMS Rugged IP67 Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 3000 Series Wireless Digital Multimeters with Fluke Connect
- Fluke 114 Electrical Digital Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Digital Multimeter with remote display
- Fluke 83V Industrial Multimeter
- Fluke 28 II EX Intrinsically Safe Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged IP67 Digital Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 1587 FC Insulation Multimeter
Key features
The Fluke 287 digital multimeter quickly graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Zoom on trend allows to view and analyze TrendCapture data; zoom in up to 14 times.
- Selectable AC filter helps display a steadier reading when the input signal is changing rapidly or noisy.
- Multiple sets of measurement information can be simultaneously displayed at the same time.
Product overview: Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
Fluke 287 Digital Multimeter
Fluke 287 True-RMS Electronics Logging Digital Multimeter is now compatible with Fluke Connect® Mobile App
The Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend.
The Fluke 289 and Fluke 287 represent the next generation of high-performance industrial logging multimeters, including higher accuracy and greater troubleshooting convenience than ever before. With the ability to log data and review it graphically on the large display, you can solve problems faster and help minimize downtime, while working at several locations.
Other useful features- NEW – Now compatible with Fluke Connect mobile app and all Fluke FC enabled test tools with optional ir3000 FC infrared connector (sold separately).
- NEW – Let your team see what you see in an instant with ShareLive™ video call (requires Fluke Connect mobile app and ir3000 FC wireless connector).
- TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
- Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
- Large 50,000 count, 1/4 VGA display with white backlight. Multiple sets of measurement information can be simultaneously displayed at the same time.
- Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.
- On board help screens for measurement functions.
- Saved measurements allow you to name and recall measurements made in the field.
- Multi-lingual interface.
- Multiple logging sessions possible without download.
- 0.025% basic DC accuracy.
- 100 kHz AC bandwidth.
- Real time clock for automatic time stamping of saved readings.
- True-RMS AC voltage and current for accurate measurements on complex signals or non-linear loads. AC bandwidth specified to 100 kHz.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
- Temperature function.
- Relative mode to remove test lead resistance from low ohms or capacitance measurements.
- Peak capture to record transients as fast as 250 μs.
- Premium test leads and alligator clips included.
- Amp jack plugs included.
- Optional FlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.
- Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
- Limited lifetime warranty.
Includes
- TL71 Test Leads
- AC175 Alligator Clips
- Batteries – 6 AA Installed
Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
What's in the box:
- Fluke 287 True-RMS Electronics Logging Multimeter
- (1 pair) TL71 Test Leads
- (1 pair) AC175 Alligator Clips
- 6 AA batteries (installed)
- Quick reference guide
Specifications: Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
Specifications | ||
Function | ||
DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.025% | |
AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.4% (True-RMS) | |
DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.05% | |
AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.6% (True-RMS) | |
Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
Basic accuracy | 1.0% | |
Resistance | Range / resolution | 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
Basic accuracy | 0.05% | |
Capacitance | Range / resolution | 1.000 n, 10.00 nF, 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
Basic accuracy | 1.0% | |
Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic accuracy | 0.005% | |
Connectivity | Optional infrared connector via Fluke ir3000 FC | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 6 AA alkaline batteries, IECLR6 | |
Battery life | 100 hours minimum, 200 hours in logging mode | |
Temperature | Operating | -20°C to 55°C |
Storage | -40°C to 60°C | |
Relative humidity | 0 to 90% (0 t 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
Electromagnetic compatibility | EMC EN61326–1 | |
Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
Shock | 1 meter drop per IEC/EN 61010–1 3rd Edition | |
Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
Weight | 870.9 g (28 oz) | |
Multiple on screen displays | Yes | |
True-RMS AC bandwidth | 100 kHz | |
dBV/dBm | Yes | |
DC mV resolution | 1 μV | |
Megohm range | Up to 500 MΩ | |
Conductance | 50.00 nS | |
Continuity beeper | Yes | |
Battery/fuse access | Yes/Yes | |
Elapse time clock | Yes | |
Time of day clock | Yes | |
Min-max-avg | Yes | |
Peak | 250 μs | |
Duty cycle | 0.01% to 99.99% | |
Pulse width | 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms | |
Hold | Yes | |
Isolated optical interface | Yes | |
Auto/touch hold | Yes | |
Reading memory | Yes | |
Log to PC | Yes | |
Interval/event logging | Yes | |
Logging memory | Up to 10,000 readings | |
Wireless connectivity (optional) | Yes |
Models: Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
Includes:
- Fluke 287 True-RMS Electronics Logging Multimeter
- TL71 Test Leads
- AC175 Alligator Clips
- Batteries – 6 AA Installed
Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
how long can this record ac voltage for? Im looking to record at least 4hrs to see if i have a voltage loss somewhere in that time frame
Will "Fluke 287 True-RMS Electronics Logging Multimeter" log the Ohm measurement and temperature the measurement is at?
Good day! In the logging form, it showed the Reading, Sample, start time, Description & Stop Time etc., can I ask in the Description what does "Interval", "Unstable" and "Stable" mean? when, why & how these descriptions occur?
Manuals + resources: Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
- Saving measurements with AutoRecord™ measurements
- How to email a measurement using the Fluke Connect app
- What is Fluke Connect®
- Connecting multiple tools at the same time with Fluke Connect®
- Performing predictive maintenance with Fluke Connect™
- Connecting the T3000 FC with the Fluke Connect™ app
- Measuring from a safe distance using the Fluke Connect™ app
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Viewing and graphing three phase measurements
- Measurement history in one place using EquipmentLog™ history
- How to create an equipment baseline with EquipmentLog™ history
- Connecting a thermal imager to your iPhone