Fluke 113 Digital Multimeter
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V TRMS Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 TRMS Digital Multimeter with temperature readings
- Fluke 117 Electricians Multimeter with Non-Contact voltage
- Fluke 115 Digital Multimeter for Technicians
- Fluke 177 True-RMS Digital Multimeter with display backlight
- Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
- Fluke 28 II TRMS Rugged IP67 Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture
- Fluke 3000 Series Wireless Digital Multimeters with Fluke Connect
- Fluke 114 Electrical Digital Multimeter
- Fluke 233 Digital Multimeter with remote display
- Fluke 83V Industrial Multimeter
- Fluke 28 II EX Intrinsically Safe Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged IP67 Digital Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 1587 FC Insulation Multimeter
Key features
- VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
- Large backlit display
- CAT IV 600 V safety rated
Product overview: Fluke 113 Digital Multimeter
The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems. The 113 features a large, backlit display for easy visibility in low-lit work environments. Plus, the integrated holster includes probe holders on the back, so your test leads can always be kept organized and where you need them.
Make measurements quickly with the 113Whether you’re a utility worker, linesman, electrician, technician, anyone else working with basic electrical testing, the Fluke 113 includes the measurement features you need to tackle your job. The Fluke VCHEK™ LoZ low impedance measurement function lets users perform tests for voltage or continuity from the same dial position.
Please note that low impedance LoZ measurements will cause a low load on a circuit protected by a RCD, which will trip powered GFCI and RCD circuits when measuring Phase to Earth.
The meter also displays AC or DC voltage, depending on what was detected, while also rejecting ghost voltages from adjacent wires. If no voltage is detected, a continuity test is performed. The Min/Max function lets you record signal fluctuations.
The Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
Specifications: Fluke 113 Digital Multimeter
Specifications | ||
VCHEK1 2 3 | Range | 6.000 V / 60.00 V / 600.0 V |
Resolution | 0.001 V / 0.01 V/ 0.1 V | |
Accuracy | DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3 | |
Diode test4 | Range | 2.000 V |
Resolution | 0.001 V | |
Accuracy | 2.0% + 3 | |
Continuity4 | Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ω4 | Range | 600.0 Ω / 6.000 kΩ / 60.00 kΩ |
Resolution | 0.1 Ω / 0.001 kΩ / 0.01 kΩ | |
Accuracy | 0.9% + 2 / 0.9% + 1 / 0.9% + 1 | |
Capacitance4 | Range | 1000 nF / 10.00 μF / 100.0 μF / 9999 μF |
Resolution | 1 nF / 0.01 μF / 0.1 μF / 1 μF | |
Accuracy | 1.9% + 2 100 μF - 1000 μF: 1.9% + 2 1000 μF: 5% + 20 | |
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. | ||
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Display | 3 3/4-digits, 6000 counts, updates 4/sec | |
Operating temperature | -10°C to 50°C (14°F to 122°F) | |
Storage temperature | -40°C to 60°C (-22°F to 140°F) | |
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating altitude | 2,000 m | |
Storage altitude | 10,000 m | |
Relative humidity | 95% to 30°C 75% to 40°C 45% to 50°C | |
Battery type | 9 Volt Alkaline, IEC 6F22 | |
Battery life | Alkaline: 300 hours typical, without backlight | |
Size (H x W x L) | 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) | |
Weight | 13.0 oz (404 g) | |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600V | |
EMI regulations | Complies with FCC Part 15, Class B | |
Specifications | ||
VCHEK | Input impedance (nominal) | ~3 kΩ < 300 pF |
VCHEK | Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at DC, 50 or 60 Hz |
Ω | Open circuit test voltage | < 2.7 VDC |
Full scale voltage | < 0.7 VDC | |
Diode test | Open circuit test voltage | 2.7 VDC |
Full scale voltage | 2.000 VDC | |
Ω | Short circuit current | < 350 μA |
Diode test | Short circuit current | < 1.0 mA |
Models: Fluke 113 Digital Multimeter
Includes:
- Fluke TL75 test leads
- Holster
- Users manual
- and 9 V battery (installed)