Key features

The 116 digital multimeter is a digital multimeter designed specifically for heating, ventilation and air conditioning (HVAC) professionals.

  • Includes built-in thermometer
  • Microamps to test flame sensors
  • Large white LED backlight

Product overview: Fluke 116 HVAC Multimeter with Temperature and Microamps

Fluke 116 HVAC Multimeter with Temperature and Microamps

The Fluke 116 Digital Multimeter provides the features you need to quickly troubleshoot HVAC equipment

The Fluke 116 HVAC multimeter was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 digital multimeter also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.

Other useful features:

  • Digital multimeter designed specifically for HVAC professionals
  • Includes built-in thermometer to measure temperature from -40°C to z400°C (-40°F to 752°F)
  • Provides microamps to test flame sensors
  • Features low input impedance to helps prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated"" For HVAC technicians, building maintenance

Includes:

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

What's in the box:

  • Fluke 116 Digital Multimeter 
  • (1 pair) 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • Quick reference guide

Specifications: Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to + 50°C
Storage temperature-40°C to + 60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode TestRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z CapacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
Temperature²
(Type-K thermocouple)
Range/resolution-40°C to 400°C / 0.1°C
Accuracy1% + 10²
Range/resolution-40°F to 752°F / 0.2°F
Accuracy1% + 18²
AC μA true-rms (45 Hz to 500 Hz)Range/resolution600.0 μA / 0.1 μA
Accuracy1.5% + 3
DC μampsRange/resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Models: Fluke 116 HVAC Multimeter with Temperature and Microamps

Fluke 116
Fluke 116 Digital Multimeter

Buy it

Includes:

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

what size screw holds the battery cover on?

Asked by: JCan
  • y_2024, m_11, d_19, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_3739292696628, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 27.65ms
  • QUESTIONS, PRODUCT
Rated 4 out of 5 by from Quality test equipment Order was easy Shipment was fast! I was satisfied.
Date published: 2023-12-15
Rated 5 out of 5 by from One of the best! the operation is smooth and sure Outstanding meter made rock solid as all of our better meters.
Date published: 2023-10-03
Rated 5 out of 5 by from Another Good Quality Fluke Meter Nice mix of features, size of buttons and display, backlight is great for dark spaces. I have used many brands of meters over the years and I always come back to Fluke for the ruggedness and reliability. They have a quality feel to their products that make them stand out vs other brands that feel cheap.
Date published: 2023-05-01
Rated 5 out of 5 by from Great, but… The meter is great, but it would be nice if it came with a holster and magnet strap clip.
Date published: 2022-02-06
Rated 5 out of 5 by from YOUR BEST HVAC INVESTMENT I HAVE USED THIS MULTIMETER FOR THE LAST 6 YEARS AS AN HVAC/R SERVICE TECHNICIAN. YOU CANT GO WRONG WHEN YOU PURCHASE FLUKE. THIS METER HAS BEEN THROUGH HELL AND BACK AND STILL WORKS LIKE A CHAMP. FROM 150F+ ATTICS TO A SOLID WEEK OF SOME OF OKLAHOMA'S COLDEST COLD SNAP IN FEB. OF 2021, IT DIDNT MISS A BEAT!
Date published: 2021-04-26
Rated 5 out of 5 by from 116 meter Great meters will not buy any other brand , have tried the other ones and they do not compare
Date published: 2020-12-30
Rated 4 out of 5 by from perfect except for display I have used a lot of Fluke meters as a field service tech. Recently bought this one and love the size and features, but was disappointed that the screen is not as clear and bold as others. It washes out when viewed from above even by a slight angle. Fluke should address this, especially since many lower costing meters have much better displays.
Date published: 2020-01-28
Rated 2 out of 5 by from Battery door screw isn't secured to the case Good meter overall, accurate and easy to use. Backlight is great. However, the screw that holds the battery door isn't permanently attached. HVAC work frequenly involves outdoor use, in the grass. Goodbye screw! Cheap children's toys have solved this problem by using screws that won't come disconnected from the battery door. Battery door also won't snap shut without the screw in place, rendering the meter useless. To add insult to injury, the screw size isn't in the specifications of the user manual, so you can't easily replace a lost screw. Unacceptable for a tool in this price range.
Date published: 2018-11-22
  • y_2024, m_11, d_20, h_14
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_3, tr_33
  • loc_en_US, sid_3739292696628, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 27.43ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat