Fluke 1735 Three-Phase Power Quality Logger

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 162.56ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 1735 Three-Phase Power Quality Logger
  • Fluke 1735 Three-Phase Power Quality Logger

Key features

The Fluke 1735 Three-Phase Power Quality Logger is the most versatile multi-purpose power quality logger for energy studies, basic power quality logging and load studies.

  • Record power and associated parameters for up to 45 days
  • Monitor maximum power demand over user-defined averaging periods
  • Prove the benefit of efficiency improvements with energy consumption tests

Product overview: Fluke 1735 Three-Phase Power Quality Logger

Fluke’s 1735 Three-Phase power quality logger is Fluke's most versatile multi-purpose power quality and energy analyzer on the market for the price and is the ideal power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events.

Most Common Applications:
  • Load studies - verify electrical system capacity before adding loads
  • Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
  • Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
  • Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
Key features
  • Record power and associated parameters for up to 45 days
  • Monitor maximum power demand over user-defined averaging periods
  • Prove the benefit of efficiency improvements with energy consumption tests
  • Measure harmonic distortion caused by electronic loads
  • Improve reliability by capturing voltage dips and swells from load switching
  • Easily confirm instrument setup with color display of waveforms and trends
  • Measure all three phases and neutral with included 4 flexible current probes
  • View graphs and generate reports with included Power Log software
  • Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty

Specifications: Fluke 1735 Three-Phase Power Quality Logger

Specifications
GeneralDisplay¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
QualityDeveloped, designed and manufactured according to DIN ISO 9001
Memory4 MB Flash memory, 3.5 MB for measuring data
InterfaceRS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate10.24 kHz
Line frequency50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supplyNiMH battery-pack, with ac adapter (15 V to 20 V / 0.8 A)
Operation time with batteryTypical > 12 hours without backlight and > 6 hours with backlight high
Dimensions240 x 180 x 110 mm
Weight1.7 kg, including battery
Ambient conditionsWorking temperature range-10°C to +50°C
Storage temperature range-20°C to +60°C
Operating temperature range0°C to +40°C
Reference temperature range23°C ±2°C
The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient±0.1% of the measured value per°C from the reference
Intrinsic errorRefers to reference temperature, maximum deviation is guaranteed for two years
Operating errorRefers to operating temperature range, maximum deviation is guaranteed for two years
Climatic classC1 (IEC 654-1) -5°C to +45°C, 5% to 95% RH, no dew
HousingCycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMCEmissionIEC/EN 61326-1:1997 class B
ImmunityIEC/EN 61326-1:1997
SafetySafetyIEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
ProtectionIP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurementMeasuring range57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V AC
Intrinsic error±(0.2% of measured value + 5 digits)
Operating error±(0.5% of m. v. + 10 digit)
Resolution0.1 V
V-rms delta measurementMeasuring range100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V AC
Intrinsic error±(0.2% of m. v. + 5 digit)
Operating error±(0.5% of m. v. + 10 digit)
Resolution0.1 V
A-rms measurementFlexi set I ranges15 A/150 A/3000 A rms (at sine)
Current clamp ranges1 A/10 A
Resolution0.01 A
Ranges150 A/3000 A and 1 A/10 A
Intrinsic error±(0.5% of m. v. + 10 digit)
Operating error±(1% of m. v. + 10 digit)
Ranges15 A
Intrinsic error±(0.5% of m. v. + 20 digit)
Operating error±(1% of m. v. + 20 digit)
 The errors of the current probes are not considered.
By using Flexi-setFlexi Set measuring error±(2% of m. v. + 10 digit)
Position influence±(3% of m. v. + 10 digit)
CF (typical)2.83
When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- Reactive, D - DistortingMeasuring rangesee V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error±(0.7% of m.v. +15 digit)
Resolution1 kW
Operating error±(1.5% of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error±(0.7% of m.v. +15 digit)
Resolution1 W to 10 W
Operating error±(1.5% of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)Intrinsic error±(0.7% of m.v.+ F variation error* + 15 digit)
Resolution1 W to 10 W
Operating error±(1.5% of m.v. + F variation error1 + 20 digit)
 1. Frequency variation error
PF (Power factor)Range0.000 to 1.000
Resolution0.001
Accuracy±1% of full scale
Frequency measurementMeasuring range46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error±(0.2% of m. v. + 5 digit)
Operating error±(0.5% of m. v.+ 10 digit)
Resolution0.01 Hz
HarmonicsMeasuring rangeTo 50th harmonic (< 50% of nom)
AccuracyVm, Im, THDV, THDIIEC 61000-4-7:2002, Class II
Vm ≥ 3% Vn±5% Vm
Vm < 3% Vnom±0.15% Vnom
Im ≥ 10% Inom±5% Im
Im < 10% Inom±0 5% Inom
THDVfor THD < 3% ±0.15% at Vnom
for THD ≥ 3% ±5% at Vnom
THDIfor THD < 10% ±0.5% at Inom
for THD ≥ 10% ±5% at Inom
VnomNormal voltage range
InomNominal current range
Vm and Im are measured values of harmonic m
Events Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error±(1% of m.v. + 10 digit)
Operating error±(2% of m.v. + 10 digit)
Resolution0.1 V

Models: Fluke 1735 Three-Phase Power Quality Logger

Fluke 1735
Fluke 1735 Three-Phase Power Quality Logger

Buy it

Includes:

  • Includes soft carrying case
  • 4 flexible current probes (15 A/150 A/3000 A)
  • Power Log software
  • Voltage leads and clips
  • Color localization set
  • PC interface cable
  • International ac adapter (115/230 V, 50/60 Hz)
  • Printed English manual
  • Multi-language manual CD
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 189.8ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 97.72ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat