7911A2 Constant Temperature Ice Bath

  • No image available

Principais recursos

  • Proporciona menos incerteza no ponto zero a ±0,002 °C de uniformidade.
  • Solução a um valor acessível com excelente uniformidade e estabilidade.
  • Capaz de verificar/calibrar várias pontas de prova ao mesmo tempo.
  • Dewar de aço inoxidável isolado a vácuo para proporcionar longevidade na obtenção do ponto de gelo.
  • Mecanismo de agitação de “calha de fluxo” projetado pela Rosemount para garantir a capacidade de repetição do ponto de gelo.

Informações gerais sobre o produto: 7911A2 Constant Temperature Ice Bath

  • Lower uncertainty zero-point (to ± 0.002 °C uniformity)
  • Affordable—amazing price for this uniformity and stability
  • Many probes can be checked/calibrated at once

Take a look at this easy and affordable zero-point source for calibrating temperature sensors—the Fluke Calibration 7911A2 Constant Temperature Ice Bath.

Now you can attain lower uncertainties from a simple ice bath. Most people don’t realize just how much uncertainty a stationary ice mixture in a typical ice bath can have. Pockets of non-uniform temperature will wreak havoc on your calibration uncertainties. With a stirred ice bath, the uniformity and stability can easily drop to ± 0.002 °C. Now that’s more like it!

The 7911A2 has a 5-liter tank with a depth of 12 inches. This gives you an optimal calibration zone of 2.5" diameter by 8" deep—enough space to calibrate several probes at once, including odd-shaped or short probes. Think how many thermocouple cold junctions you could put in this bath!

As with all Hart products, the model 7911A2 Constant Temperature Ice Bath is manufactured according to a proven design using the best components.

The vacuum-insulated stainless steel dewar is used to give your ice-point realization longevity (a well-prepared ice bath can be used for several hours without attention).

We use a Rosemount-designed “flow chute” stirring mechanism to saturate the bath water with air as it stirs. Having the same concentration of air in the mixture each time increases the repeatability of the ice point.

Using pure distilled or demineralized water for bath fluid and ice, you’ll consistently produce a 0 °C calibration environment with up to ± 0.002 °C accuracy.

For thermometer calibrations or for a thermocouple cold junction temperature source, if you want the best ice bath results, use the best equipment available—get the Fluke Calibration 7911A2.

Especificações: 7911A2 Constant Temperature Ice Bath

Specifications
Uniformity± 0.002 °C
Stability± 0.002 °C
Optimal Temp. Zone64 mm dia. x 203 mm D (2.5 x 8 in)
Size185 mm dia. x 490 mm D (7 x 19 in)
Tank Capacity5 Liters, 150 mm dia. x 300 mm D (6 x 12 in)
Weight13.5 lb (6.1 kg)
Power115 V ac (± 10 %), 60 Hz, 1 A or
230 V ac (± 10 %), 50 Hz, 0.5 A
based on a properly made ice bath mixture

Modelos: 7911A2 Constant Temperature Ice Bath

7911A2
Constant Temperature Ice Bath