Fluke 87V MAX True-rms Digital Multimeter
Compare products: digital multimeters
- Fluke 87V TRMS Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 TRMS Digital Multimeter with temperature readings
- Fluke 117 Electricians Multimeter with Non-Contact voltage
- Fluke 115 Digital Multimeter for Technicians
- Fluke 177 True-RMS Digital Multimeter with display backlight
- Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
- Fluke 28 II TRMS Rugged IP67 Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 3000 FC Series Wireless Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 107 Pocket Digital Multimeter
- Fluke 1587 FC Insulation Multimeter
Key Features
- This electrical multimeter contains all the trusted features of the most popular multimeter used today, the Fluke 87V, plus much more.
- More rugged: The 87V MAX multimeter withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
- Use it everywhere: Waterproof, dustproof IP67 case for the most extreme work sites
- Easy to use: Large display digits, backlit keys for dark environments and double the battery life of the 87V (up to 800 hours)
- Save time: Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Premium TL175 TwistGuard™ test leads
Product overview: Fluke 87V MAX True-rms Digital Multimeter
The Fluke 87V MAX trms multimeter defines a new standard for operating in extreme conditions, with the features and accuracy to troubleshoot most electrical problems
Withstands drops up to 4-meters (13 feet)
Fluke’s most rugged digital multimeter. The 87V MAX is a trms multimeter built with an industrial strength case and a removable holster. The holster doubles as a test probe holder for one-handed operation.
IP67 rated
This Fluke digital multimeter is fully waterproof and dust proof, to work reliably in all the places that you need to work.
Withstands heat and cold
The Fluke 87V MAX TRMS multimeter has an extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.
Other product highlights
- True-rms ac voltage and current for accurate measurements on non-linear signals
- Measure up to 1000 V ac and dc
- Measure up to 10 A (20 A for 30 seconds)
- Frequency to 200 kHz
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Min/Max/Average recording, plus 250 μs Peak min-max to capture variations automatically
- Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment
- This electrical multimeter has a large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility
- Hi resolution 19,999 count display mode
- Long battery life (800 hours)
Comparison – 87V MAX multimeter and 87V multimeter
87V MAX ; 87 V
IP Rating: IP 67 ; IP 30
Battery life: 800 hours; 400 hours
Drop test: 4 meters ; 3 meters
Backlit keypad: Yes ; No
TwistGuard™ test leads: Yes ; No
True-rms readings: ac ; ac
Basic dc accuracy: 0.05% ; 0.05%
Voltage ac/dc: 1000 V ;1000 V
Current ac/dc :10 A ; 10 A
Resistance: 50 MΩ ; 50 MΩ
EN61010-1 CAT III: 1000 V ; 1000 V
EN61010-1 CAT IV: 600 V ; 600 V
Warranty (years) Limited lifetime : Limited ; lifetime
What's in the box:
- Fluke 87V MAX True-rms Digital Multimeter
- TL175 TwistGuard® test leads
- AC175 Alligator clips
- 80BK-A temperature probe
- Removable holster with test lead storage
- Three AA batteries (installed)
Specifications: Fluke 87V MAX True-rms Digital Multimeter
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe | |
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS |
Min/Max/Avg | Yes | |
Reading hold/Auto (Touch) Hold | Yes | |
Relative reference | Yes | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph | 32 segments, updates 40/second | |
Backlight | Two level | |
Low pass filter (VFD measurements) | Yes | |
Input Alert™ | Yes | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V | |
Agency approvals | CE, CSA | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67 | |
Power | Three AA batteries. 800 hours typical, without backlight | |
Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
Weight | 698.5 g (with holster) | |
Warranty | Limited lifetime | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
Storage temperature | -40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Operating altitude | 2000 m |
Models: Fluke 87V MAX True-rms Digital Multimeter
Fluke 87V MAX True-rms Digital Multimeter
Includes:
- TL175 TwistGuard® test leads
- AC175 Alligator clips
- 80BK-A temperature probe
- Removable holster with test lead storage
- Three AA batteries (installed)