720A Kelvin-Varley Divider

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 142.31ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 720A Kelvin-Varley Divider
  • 720A Kelvin-Varley Divider
  • 720A Kelvin-Varley Divider

Key features

  • High-resolution primary standard for ratio measurements
  • 0.1 ppm of input absolute linearity, 0.1 ppm resolution, seven decades
  • Temperature coefficient of linearity of 0.1 ppm/ºC
  • Built-in self-calibration bridge

Product overview: 720A Kelvin-Varley Divider

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Learn more

A primary standard for ratio measurements


Model 720A Kelvin-Varley Divider is a high-resolution primary ratio standard with absolute linearity of 0.1 ppm, temperature coefficient of linearity of 0.1 ppm/ºC, and self-calibration capability.

  • 0.1 ppm resolution, seven decades
  • 0.1 ppm of input absolute linearity
  • Built-in self calibration bridge
  • Front panel self-calibration

Specifications: 720A Kelvin-Varley Divider

General specifications
Ratio range0 to 1.0 (1.0 input tap) and 0 to 1.1 (1.1 input tap)
Resolution0.1 ppm of input with seven decades 0.2
Absolute linearity(At calibration temperature and without the use of a correct chart) ±1.0 ppm of input at dial settings of 1.1 to 0.1, ±0.1 (10S)1/3 of input at dial settings (S) of 0.1 to 0
Absolute linearity stability(Without self-calibration) ±1.0 ppm of input/yr at dial settings of 1.1 to 0.1, ±1.0
(10S)(2/3) ppm of input/yr at dial setting (S) of 0.1 to 0
Note: Absolute linearity is defined as the linearity between max and min output voltages. The self-calibration procedure may be used at any time to reset absolute linearity to ±0.1 ppm of input.
Temperature coefficient of linearity±0.05 ppm of input ºC maximum at dial settings of 1.1 to 0.1
Short-term linearity stabilityUnder typical standards laboratory conditions (temperature maintained within ± 1 ºC) and with an applied voltage of up to 100V, stability of linearity is ± 0.01 ppm/24 hours and ± 0.1 ppm/30 days
Power coefficient of linearity±0.2 ppm of input/W max at dial settings of 1.1 to 0.1; ±0.2 (10S) 2 ppm of input/W max at dial settings (S) of 0.1 to 0
Maximum end errorsZero error at output low: 0.004 ppm of input
Zero error at input low: 0.05 ppm of input
Full-scale error: 0.05 ppm of input
Maximum input voltage1000 V on 1.0 input terminal, 1100 V on 1.1 input terminal
Thermal voltages±0.5 μV max
Input resistance100 kΩ ±0.005% at 1.0 input terminal at 25 °C, 110 kΩ ±0.005% at 1.1 input terminal at 25 °C
Temperature coefficient of input resistance±1 ppm per °C max
Size14 cm H x 48.2 cm W x 33 cm D, rack mounted (5.5 in H x 19 in W x 13 in D)
Weight8.15 kg (18 lb)

Models: 720A Kelvin-Varley Divider

720A
Kelvin-Varley Voltage Divider

Buy it
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 126.2ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 28.61ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat