VT04 Visual IR Thermometer Maintenance Combo Kit
Model#: Fluke VT04-Maint-Kit
Tidak Diproduksi Lagi
Fitur utama
- Unlimited applications – See data sheet for powerful applications and details
- Built-in digital camera – Every Fluke Visual IR Thermometer has a built-in digital camera
- Exclusive thermal heat map blending overlay – With one button, blend digital images and thermal heat maps to instantly show the exact location of the issue
- No training required - Fully automatic with built-in intelligence
- True pocket size design – Less than half the size of an average infrared camera
- SmartView® reporting software – Store up to 10,000 images per Gb on included SD card and make professional reports on included professional software
- Automatic hot and cold spot trackers
- Breakthrough affordability – Fraction of the cost of infrared cameras that require costly training and software
- Powerful resolution with PyroBlend® Plus optics:
- Best-in-class field of view: 28 ° x 28 ° (40% wider for tight spaces)
- 4 times sharper images
- Alarm and time lapse features:
- Hi/Lo temperature alarm – Find hot spots in seconds with the alarm feature
- Time lapse image capture – Automatically monitor equipment over time
- Automated monitoring alarm – Automatically capture images after an alarm has been triggered
Produk ini dihentikan atau diklasifikasikan ulang
Ikhtisar Produk: VT04 Visual IR Thermometer Maintenance Combo Kit
VT04 dan Fluke 1507 Insulation Resistance Tester merupakan teman ideal untuk aplikasi pemecahan masalah dan pemeliharaan preventif.
Spesifikasi: VT04 Visual IR Thermometer Maintenance Combo Kit
Fluke VT04 Visual IR Thermometer
| Fitur Utama | |
| Kamera digital bawaan | Ya |
| Lapisan peta panas termal | Ya, lima mode kombinasi |
| Sistem optik citra | Optik PyroBlend® Plus gambar 4x lebih tajam daripada VT02 |
| Medan pandang | 28° x 28° |
| Alarm suhu HI-Lo | Ya |
| Tangkapan gambar selang waktu | Ya |
| Alarm monitor otomatis | Ya |
| Jenis Baterai | Li-Ion dapat diisi ulang |
| Pelatihan | Tidak perlu pelatihan |
| Ergonomik | Desain ramping seukuran saku |
| Penanda panas dan dingin | Ya |
| Fitur Umum | |
| Daya tahan baterai | Delapan (8) jam |
| Rentang pengukuran suhu | -10°C s/d +250°C (14°F s/d 482°F) |
| Akurasi pengukuran suhu | ±2°C atau ±2% |
| Pengukuran suhu | Ya, titik tengah |
| Media penyimpanan (kartu mikro SD) | Menyimpan hingga 10.000 gmabar per GB (Kartu empat (4) GB disertakan) |
| Pita spektrum inframerah | 6,5 µm sampai 14 µm |
| Tinggi dan bentang | Otomatis |
| Mekanisme fokus | Bebas fokus, tidak dibutuhkan pelatihan dan dengan kecerdasan bawaan |
| Opsi fokus-opsi NEAR/FAR yang secara eksklusif dapat dipilih oleh pengguna | NEAR > 23 cm (9 in); FAR < 23 cm (9 in) |
| Dimensi | 21 x 7,5 x 5,5 cm (8,3 x 3 x 2,2 in); < 350 g. (12,5 oz.) |
| Fileformat | Format .is2 disimpan ke kartu SD Pengguna dapat membuat laporan secara profesional atau mengekspor gambar dalam SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF dan TIFF) |
| Keamanan dan kesesuaian | CFR47:2009 Kelas A. Komponen 15 subkomponen B; CE EN 61326:2006; IEC/EN 61010-1:2010 |
| Garansi | Dua (2) tahun |
Fluke 1507/1503 Insulation Resistance Testers
| Pengukuran Tegangan AC/DC | ||
| Akurasi | Rentang | 600,0 V |
| Resolusi | 0,1 V | |
| 50 Hz s/d 400 Hz ± (% of Rdg + Digit) | 23 | |
| Impedansi input | 3 MΩ (nominal) 100 pF | |
| Rasio penolakan mode umum selisih 1 kΩ | 60 dB pada dc 50 atau 60 Hz | |
| Perlindungan Beban Berlebih | Rms atau dc 600 V | |
| Pengukuran Tahanan Ikatan Bumi | ||
| Rentang/Resolusi | 20,00 Ω | 0,01 Ω |
| 200,0 Ω | 0,1 Ω | |
| 2000 Ω | 1,0 Ω | |
| 20,00 kΩ | 0,01 kΩ | |
| Akurasi | ±(1,5% + 3) | |
| Perlindungan Beban Berlebih | Rms atau dc 2 V | |
| Tegangan Uji Sirkuit Terbuka | > 4,0 V, < 8 V | |
| Arus hubung singkat | > 200,0 mA | |
| Spesifikasi Insulasi | ||
| Rentang pengukuran | 1507 | 0,01 MΩ s/d 10 GΩ |
| 1503 | 0,01 MΩ s/d 2.000 MΩ | |
| Teganganuji | 1507 | 50 V, 100 V, 250 V, 500 V, 1000 V |
| 1503 | 500 V, 1000 V | |
| Akurasi tegangan uji | +20%, - 0% | |
| Arus hubung singkat | nominal 1 mA | |
| Otomatis pelepasan daya otomatis | Waktupelepasan < 0,5 detikuntuk C = 1 µF ataukurang | |
| Indikator sirkuit langsung | Membatalkan pengujian jika tegangan terminal > 30 V sebelum penyiapan pengujian | |
| Muatan kapasitif maksimum | Dapat dioperasikan dengan muatan hingga 1 µF | |
| Akurasi pengukuran | 50 V | ±(3% + 5) |
| 100 V | ±(3% + 5) | |
| 250 V | ±(1,5% + 5) | |
| 500 V | ±(1,5% + 5) | |
| 1000 V | ±(1,5% + 5) s/d 2.000 MΩ ±(10% + 3) diatas 2.000 MΩ | |
| Spesifikasi Umum | ||
| Tegangan maksimum yang diterapkan di setiap terminal | Rms atau dc ac 600 V | |
| Suhu penyimpanan | -40°C sampai 60°C (-40°F sampai 140°F) | |
| Suhu pengoperasian | -20°C sampai 55°C (-4°F sampai 131°F | |
| Koefisien suhu | 0,05 x (akurasi tertentu) per °C untuk suhu < 18°C atau > 28°C (< 64°F atau > 82°F) | |
| Kelembapan relatif | 0% s/d 95% @ 10°C s/d 30°C (50°F s/d 86°F) | |
| 0% s/d 75% @ 30°C s/d 40°C (86°F s/d 104°F) | ||
| 0% s/d 40% @ 40°C s/d 55°C (104°F s/d 131°F) | ||
| Getaran | Acak 2 g 5 - 500 Hz per MIL-PRF-28800F Instrumen kelas 2 | |
| Guncangan | Jatuh 1 meter per Edisike 2 IEC 61010-1 (tes jatuh 1 meter enam sisi lantai kayu oak) | |
| Kompatibilitas elektromagnetik | Pada medan RF 3 V/M akurasi = akurasi tertentu (EN 61326-1:1997) | |
| Keselamatan | Mematuhi ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, dan Edisi ke-2 IEC/EN 61010-1 untuk kategori pengukuran IV 600 V (CAT IV) | |
| Sertifikasi | CSA per standar CSA/CAN C22.2 No. 61010.1-04; TUV per standar Edisi ke-2 IEC/EN 61010-1 | |
| Baterai | Empat baterai AA (NEDA 15A atau IEC LR6) | |
| Daya tahan baterai | Penggunaan uji insulasi | Penguji dapat melakukan sedikitnya 1.000 uji Insulation dengan baterai alkaline yang baru pada suhu ruangan. Berikut adalah uji standar 1.000 V ke 1 MΩ dengan siklus kerja 5 detik hidup dan 25 detik mati. |
| Hambatan pengukuran | Penguji dapat melakukan sedikitnya 2.500 pengukuran tahanan dengan baterai alkaline yang baru pada suhu ruangan. Berikut adalah uji standar 1 Ω dengan siklus kerja 5 detik hidup dan 25 detik mati. | |
| Ukuran | 5,0 cm H x 10,0 cm W x 20,3 cm L (1,97 untuk H x 3,94 untuk W x 8,00 untu k L) | |
| Berat | 550 g (1,2 lb) | |
| RatingIP | IP40 | |
| Ketinggian | Pengoperasian | 2.000 m CAT IV 600 V 3.000 m CAT III 600 V |
| Non-operasi (penyimpanan) | 12.000 m | |
| Kapabilitas kelebihan rentang | 110% dari rentang | |
| Aksesori yang disertakan | Kabel Uji TL224, Probe Uji TP74, jepit PN 1958654 (merah) dan PN 1958646 (hitam) sarung dan remote probe | |
Model: VT04 Visual IR Thermometer Maintenance Combo Kit
Fluke VT04-Maint-Kit
Fluke VT04 Visual IR Thermometer Maintenance Combo Kit
Includes:
VT04 Visual IR Thermometer includes:
- Hard case*
- Micro-SD card
- Micro-SD conversion adapter to standard
- Li-Ion rechargeable battery
- Printed Quick Start guides (English, French, German, Spanish, Simplified Chinese)
Available for free download*:
- SmartView® analysis and reporting software »
- Manual »
- Quick Start guide »



