PPCH 1.01n Embedded Software (.bin)
TITLE | VER | USE WITH |
PPCH™ | 1.01n 2013.07.22 | PPCH |
Instructions: | ||
Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it requires specific "-AF" embedded software. The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center. If the update isn't performed properly, your product will be inoperable until it is. | ||
Updates Include: | ||
Ver 1.01n (2013 July 22) | ||
Ver 1.00l (2005 Jul 06) CHG: Number of purge cycles allowed increased from 99 to 999. Ver 1.00k (2005 May 19) CHG: Valve travel limit applied to configurations FIX: Valve/TPC logic would be unpredictable if vent was interrupted before READY. FIX: Valve home positions could cause errors. Ver 1.00j (2005 Apr 04) ADD: Add pressure units "Torr" and "mTor". CHG: Update the head correction calculation to ensure a pressure of '0' is indicated in gauge mode when autozero occurs with an Air head. FIX: An "ABORT" quickly followed by a new target set "PS=xxx" while in monotonic mode "Segment2" aborts, but does not generate the new target. FIX: IL RPT valves do not isolate and vent RPT if PPC is idle and pressure exceeds the IL's "PMAX" limit. Works fine if PPC is controlling. FIX: A single keypress could result in multiple key actions. FIX: Front panel menu locks up if the UP or DN arrow key is pressed in a menu with selections that only span the bottom line. FIX: Dynamic mode does not hand off to TPC when pressure goes out of ready. FIX: Entering a target pressure from an active "vent" would sometimes not start a new excursion (it would be ignored). FIX: 2nd part of the user RS232 test always fails with the message "INVALID". Ver 1.00i (2004 Sep 29) FIX Remote selection of "UNIT=kcm2" was not operating correctly. FIX RPT labeleling was incorrect on product intro screen with a utility sensor in the Hi position and Q-RPT in Lo position. Ver 1.00h (2004 Jun 25) ADD: Improved valve to thermal pressure control handoff logic. Ver 1.00g (2004 Jun 01) ADD: "RESET" argument to the ABORT command which instructs the valves to close & reset after generation is aborted (for use by PG7000 AutoGen) FIX: Purge target pressure is reset to a default of 50% of the active range whenever the range is changed. Ver 1.00f (2004 May 24) FIX: Thermal pressure control (TPC) sometimes continued after returning to local front panel operation following use of TPC in response to a remote pressure command. ADD: Use leak rate when determining opening points of user and factory valve configurations. ADD: Leak check warning if excessive leak rate detected during valve configuration routine. Ver 1.00e (2004 Apr 22) ADD: Generation adjustments and improvements. ADD: Specifing a volume of '-1' with a rate or pressure set comand skips any pending volume requests for the generation. FIX: A remote to local transition while generating can leave the control valves still open. FIX: Reset SETS or reset ALL could result in a FATAL EXCEPTION message. CHG: New factory generation defaults for control. CHG: Reset user valve cfg during a reset ALL instead of s reset SETS. |