Fluke 376 FC True-RMS Clamp Meter plus insulated hand tools starter kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 468.73ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 376 FC True-RMS Clamp Meter plus insulated hand tools starter kit
  • The Fluke 376 FC true-rms clamp meter send measurements to your phone for easy storage
  • Fluke insulated linemans pliers are rated to 1000 V ac, 1500 V dc
  • Fluke insulated hand tools. 1000 V. Lifetime warranty.

Key Features

  • 376 FC: Measure AC/DC current with included iFlex current probe
  • 376 FC: VFD low pass filter for non-linear signals measurements
  • Insulated tools: certified to 1000 V AC, 1500 V DC
  • Insulated tools: ergonomic 8-piece set

Product overview: Fluke 376 FC True-RMS Clamp Meter plus insulated hand tools starter kit

The Fluke 376 FC True-RMS Clamp Meter combined with the insulated hand tools starter kit, the most often used screwdrivers, pliers and cutters.

376 FC Clamp Meter

  • 1000 A ac and dc current measurement, 2500 A ac current measurement with iFlex flexible current probe
  • 1000 V ac and dc voltage measurement
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Log and trend measurements to pinpoint intermittent faults
  • Transmit results wirelessly via Fluke Connect® Measurements app
  • Create and send reports right from the field
  • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices

Slotted screwdrivers

  • Three different bladeforms
  • Three handle lengths
  • Phillips screwdrivers, #1 and #2 tips
  • Two handle lengths

Long nose pliers with side cutter and gripping zones

  • Unique milled wave pattern gripping zones
  • 4 gripping points for pulling round objects with superior grip that won't slip
  • Straight, half-round, long and slim knurled jaws, specially profiled
  • Side cutting edge for wire cutting

Heavy duty, high leverage diagonal cutter

  • Cuts hard materials including steel and piano wire
  • Power joint and precision cutting edges

Heavy Duty Combination Pliers

  • Secure hold by aggressive serrated jaws and 4-point gripping hole
  • Slim shape for better access to wires in tight spaces
  • Powerful gripping jaw, yet 20% lighter weight than other designs ext, bullets if it makes sense

What's in the box:

  • Fluke 376 FC True-RMS Clamp Meter
  • 18-inch iFlex® Flexible Current Probe
  • (1 pair) TL75 Test Leads
  • Two AA batteries (Installed)
  • Fluke Insulated Slotted Screwdriver
    • 3/32x3 in, 2.5 mm x 75 mm, 1000V
  • Fluke Insulated Slotted Screwdriver
    • 5/32x4 in, 4 mm x 100 mm, 1000V
  • Fluke Insulated Slotted Screwdriver
    • 1/4x5 in, 6 mm x 125 mm, 1000V
  • Fluke Insulated Phillips Screwdriver #1
    • 3 in, 75 mm, 1000V
  • Fluke Insulated Phillips Screwdriver #2
    • 4 in, 100 mm, 1000V
  • Fluke Insulated Long Nose with Side Cutter
    • 8 in, 200mm, 1000V
  • Fluke Insulated High Leverage Diagonal Cutter
    • 8 in, 200mm, 1000V
  • Fluke Insulated Linesman Combination Plier
    • 8 in, 200 mm, 1000V
  • TPAK magnetic hanging strap
  • Soft carrying case
  • Roll up Pouch
  • Quick Reference Guide

Specifications: Fluke 376 FC True-RMS Clamp Meter plus insulated hand tools starter kit

General Specifications
AC Current via Jaw
Range999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
 i2500-10 Flexi2500-18 Flex
A  
Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)
Error±0.5 %±0.5 %
B  
Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)
Error±1.0 %±1.0 %
C  
Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)
Error±2.0 %±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits
AC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% ±5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range60 kΩ
Resolution0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy1% ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity -
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP ratingIEC 60529: IP30, non-operating
Radio Frequency Certification FCC IDT68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

87V Industrial Multimeter Specifications:

Voltage DCMaximum voltage1000 V
Accuracy±(0.05% + 1)
Maximum resolution10 µV
Voltage ACMaximum voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC bandwidth20 kHz with low pass filter; 3 db @ 1 kHz
Maximum resolution0.1 mV
Current DCMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.01 µA
Current ACMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) True RMS
Maximum resolution0.1 µA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.2% + 1)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
Accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyMaximum frequency200 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per khz + 0.1%)
Maximum resolution0.1%
Temperature–200.0 °C – 1090 °C
80 BK–40.0 °C – 260 °C
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty cycle rangeAccuracyWithin ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating–20 °C to + 55 °C
Storage–40 °C to + 60 °C
Humidity0% – 90% (0 °C – 35 °C)
Operating2000 m
Safety Specifications
OvervoltageEN 61010–1 to 1000 V CAT III, 600V CAT IV
AgencyUL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
DisplayDigital6000 counts updates 4/sec.
Analog32 segments, updates 40/sec
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument
Screwdriver TypeBlade length
(inches
mm)
Handle length
(inches
mm)
Handle width
(inches
mm)
Bladeform diameter
(inches
mm)
Head SlotSlot3
75
3-3/8
86
1
25
3/32
2.55
Head SlotSlot4
100
3-11/16
94
1 5/16
30
5/32
4.0
Head SlotSlot5
125
4-3/16
106
1 7/16
36
1/4
6.0
Head PhillipsPhillips #13
80
3-11/16
94
1 3/16
30
7/32
5
Head PhillipsPhillips #24
100
4-3/16
106
1 7/16
36
1/4
6
Pliers TypeNominal Length (inches)Nominal Length (mm)
Long Nose8200
Diagonal Cutters8200
Lineman Combination Pliers8200
 

Warranty

Fluke Insulated Hand Tool Lifetime Limited Warranty

Each Fluke Insulated Hand Tool will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least fifteen years from the date of purchase. This warranty does not cover damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, damage or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.

Recommendations for use and in-service care of Fluke Insulated Hand Tools

The following is guidance concerning the maintenance, inspection, retest and use of Fluke Insulated Hand Tools.

Warning – to avoid electrical shock or personal injury:

  • Keep fingers behind the finger guards of the tool. Never touch conductive parts.
  • Always wear approved eye protection.
  • Do not use in wet or damp locations. Do not use unless the tool is clean and dry.
  • Do not apply excessive force or stress to the tool insulation that may cause damage. Examples include using the insulated surfaces as a fulcrum to pry or wedge or gripping insulated tool handles with other tools such as pliers or wrenches to increase torque or leverage.

If the tool is used in a manner not specified, the protection may be impaired.

Storage

Insulated hand tools should be properly stored to minimize the risk of damage to the insulation due to storage or transportation. These insulated hand tools should be stored separated from other tools to avoid mechanical damage or confusion with uninsulated tools. Furthermore, these insulated hand tools should be prevented from contact with excessively hot surfaces (for example steam pipes) or exposure to excessive UV- radiation.

Inspection before use

Before use, each Insulated Hand Tool should be visually inspected by the user. If there is any doubt concerning the safety of the insulated hand tool, it should be subjected to examination by a competent person and if necessary retested to determine suitability or disposed of to prevent further use.

Temperature

Insulated Hand Tools should be used only in environments having temperatures between –20 °C and +70 °C and, for tools marked “C”, between –40 °C and +70 °C.

Periodic examination and electrical retesting

An annual visual examination by a suitably trained person is recommended to determine the suitability of the Insulated Hand Tool for further service. If an electrical retest is required by national regulation or in the case of doubt after visual examination, the applicable dielectric test of IEC 60900 for insulated hand tools should be performed.

For details contact a Fluke Service Center.

Models: Fluke 376 FC True-RMS Clamp Meter plus insulated hand tools starter kit

IB376K

Fluke 376 FC True-RMS Clamp Meter + Insulated Hand Tools Starter Kit (5 insulated screwdrivers and 3 insulated pliers)

 


Buy it

Includes:

  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex®
  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 test leads
  • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
  • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
  • ISLS8 Insulated Slotted Screwdriver 1/4, 5"
  • IPHS1 Insulated Phillips Screwdriver #1, 3"
  • IPHS2 Insulated Phillips Screwdriver #2, 4"
  • INLP8 Insulated Long Nose /w Side Cutter and Gripping Zones
  • INDC8 Insulated Heavy Duty High Leverage Diagonal Cutter
  • INCP8 Insulated Heavy Duty Linesman Combination Plier
  • RUP8 Roll up pouch
IB376M

Fluke 376 FC True-RMS Clamp Meter + 5 insulated screwdrivers


Buy it

Includes:

  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex®
  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 test leads
  • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
  • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
  • ISLS8 Insulated Slotted Screwdriver 1/4, 5"
  • IPHS1 Insulated Phillips Screwdriver #1, 3"
  • IPHS2 Insulated Phillips Screwdriver #2, 4"
IB376L

Fluke 376 FC True-RMS Clamp Mete + 3 insulated screwdrivers


Buy it

Includes:

  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex®
  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 test leads
  • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
  • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
  • IPHS2 Insulated Phillips Screwdriver #2, 4"
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 113.69ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.44ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat