Fluke 77 IV Digital Multimeter
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V TRMS Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 TRMS Digital Multimeter with temperature readings
- Fluke 117 Electricians Multimeter with Non-Contact voltage
- Fluke 115 Digital Multimeter for Technicians
- Fluke 177 True-RMS Digital Multimeter with display backlight
- Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
- Fluke 28 II TRMS Rugged IP67 Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 3000 FC Series Wireless Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 107 Pocket Digital Multimeter
- Fluke 1587 FC Insulation Multimeter
Key Features
- Large display
- Backlight for work in dim areas
- Min / Max to record signal fluctuations
- Ergonomic overmolded housing with integrated probe holders
- Free your hands with the optional TPAK magnetic hanger
- Auto and Manual ranging
- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
The 77 IV replaces the 77. Move up to superior utility and safety today.
Product overview: Fluke 77 IV Digital Multimeter
Versatile meters for field service or bench repair.
The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.
It measures:
- Wide 1000 V measurement range
- Average responding AC measurements
- 0.3% accuracy
- 10 Amps continuous (20 A for 30 seconds)
- Frequency and capacitance
- Resistance and continuity
What's in the box:
- Fluke 77 IV Digital Multimeter
- (1 pair) Test leads
- 9V Battery (Installed)
- Quick reference guide
Specifications: Fluke 77 IV Digital Multimeter
Specifications | ||
Voltage DC | Range | 6.000 V – 1000 V |
Best accuracy | ±(0.3% + 1) | |
Best resolution | 0.1 mV | |
Voltage AC | Range | 600.0 mV – 1000V |
Best accuracy | ±(2.0% + 2) | |
Best resolution | 1.0 mV | |
Amps AC | Range | 60.00 mA – 10 A |
Best accuracy | 2.5% + 2 | |
Best resolution | 0.01 mA | |
Amps DC | Range | 60.00 mA – 10A |
Best accuracy | 1.5% + 2 | |
Best resolution | 0.01 mA | |
Resistance | Range | 600.0 Ω – 50 MΩ |
Best accuracy | ±(0.5% + 1) | |
Best resolution | 0.1 Ω | |
Capacitance | Range | 1nF – 9,999 μF |
Best accuracy | ±(1.2% + 2) | |
Best resolution | 1 nF | |
Frequency | Range | 99.99Hz – 99.99kHz |
Best accuracy | ±(0.1% + 1) | |
Best resolution | 0.01 Hz | |
Safety | ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV | |
Certifications | CSA, TÜV (EN61010), Π, (N10140) | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Surge protection | 8 kV peak per IEC 61010 | |
Ω Fuse for mA inputs | 440 mA, 1000 V FAST Fuse | |
Ω Fuse for A inputs | 11 A, 1000 V FAST Fuse | |
Display | Digital | 6000 counts, updates 4/sec |
Bar graph | 33 segments, updates 32/sec | |
Frequency | 10,000 counts | |
Capacitance | 1,000 counts | |
Altitude | Operating | 2,000 meters |
Storage | 12,000 meters | |
Temperature | Operating | -10°C to + 50°C |
Storage | -40°C to + 60°C | |
Temperature coefficient | 0.1 x (specified accuracy / °C (< 18°C or > 28°C) | |
Electromagnetic compatibility (EN 61326–1:1997) | In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ±5°C (9°F) | |
Relative humidity (maximum non-condensing) | 90% to 35°C 75% to 40°C 45% to 50°C | |
Battery life | 400 hours typical (alkaline) | |
Size (H x W x L) | 4.3 x 9 x 18.5 cm | |
Weight | 420 g |