Fluke 719Pro Electric Pressure Calibrator
Fluke 719Pro Electric Pressure Calibrator is rated out of 5 by 5.
Key Features
- Unique integrated electric pump for one handed pressure calibration
- Test pressure switches easily with easy-to-use switch test function
- Precision pressure adjust vernier for easy and accurate pressure calibration
- Ideal accuracy and performance (0.025%) for reference class transmitter calibration
- 30 psi, 150 psi and 300 psi pressure ranges
- Programmable pressure calibrator pump limit:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 750P Pressure Modules
- Pump cleanout ports reduce pump failures from moisture and fluid damage
- Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
- Precision temperature measurement with optional RTD probe
Product overview: Fluke 719Pro Electric Pressure Calibrator
Fluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more
The 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.
Get the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:
- Pressure measurement from internal or external sensor
- Sourced/simulated or measured mA values
- Temperature measured by optional RTD probe
Specifications: Fluke 719Pro Electric Pressure Calibrator
Measurement | |||
Fluke-719Pro-30G | Range | -12 to 30 psi / -0.8 to 2 bar | |
Resolution | 0.001 psi / 0.0001 bar | ||
Fluke-719Pro-150G | Range | -12 to 150 psi / -0.8 to 10 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Fluke-719Pro-300G | Range | -12 to 300 psi / -0.8 to 20 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Accuracy | ±0.025% of full scale, 6 months ±0.035% of full scale, 1 year | ||
Temperature effect (all ranges) | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | ||
Dry air and non-corrosive gas only No effect on accuracy on all functions from 15°C to 35°C | |||
Function | Range | Resolution | Accuracy (1 year) |
mA DC (simulation and measurement) | 0-24 mA DC | 0.001 mA | ±0.015% of reading ±2 counts |
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate | |||
Volts DC (measurement only) | 30 V DC | 0.001 V | ±0.015% of reading ±2 counts |
No AC voltage measurement, do not exceed 30 V DC | |||
Temperature (measurement only, Pt100 RTD) | -50 to 150°C (-50°F to 302°F) | 0.01°C 0.01°F | Temperature ±0.1°C (0.2°F) |
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory) | |||
Loop power supply | 24 V DC | N/A | 24 mA at 24 V |
Temperature effect (all functions) | - | - | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
No effect on accuracy on all functions from 15°C to 35°C | |||
Environmental | |||
Operating temperature | -10°C to +50°C | ||
Storage temperature (with batteries) | Per battery manufacturer's specification within storage specification below | ||
Storage temperature (without batteries) | -20°C to +60°C | ||
Power Requirements | |||
Battery | Eight (8) standard Alkaline AA batteries | ||
Battery life | 300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum | ||
Physical | |||
Dimensions (H x W x D) | 24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in) | ||
Weight | With holster 1.2 kg (2.5 lb) | ||
Connections | |||
Pressure | 1/8 inch female NPT | ||
Electrical | Standard banana jacks | ||
RTD | 4 pin miniature circular | ||
External module | 6 pin miniature circular | ||
Engineering Units (Configurable) | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F |
Models: Fluke 719Pro Electric Pressure Calibrator
Fluke 719Pro 30G
Fluke 719Pro-30G Electric Pressure Calibrator
30 psig
30 psig
Includes:
- Test leads with alligator clips
- Printed user's manual and user's manual on CD-ROM in 14 languages
- Fluid trap
- Carrying case
- 1/4 inch NPT to 1/4 inch ISO adapter
- Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
- Traceable Certificate of Calibration
Fluke 719Pro 150G
Fluke 719Pro-150G Electric Pressure Calibrator
150 psig
150 psig
Includes:
- Test leads with alligator clips
- Printed user's manual and user's manual on CD-ROM in 14 languages
- Fluid trap
- Carrying case
- 1/4 inch NPT to 1/4 inch ISO adapter
- Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
- Traceable Certificate of Calibration
Fluke 719Pro 300G
Fluke 719Pro-300G Electric Pressure Calibrator
300 psig
300 psig
Includes:
- Test leads with alligator clips
- Printed user's manual and user's manual on CD-ROM in 14 languages
- Fluid trap
- Carrying case
- 1/4 inch NPT to 1/4 inch ISO adapter
- Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
- Traceable Certificate of Calibration
Rated 1 out of 5 by justin123 from 719 pro I will never buy another fluke product. i spent over 5k on a 719-300 pro unit broke after 3 weeks. I'm still trying to send this thing back to get repaired but they just transfer me from department to department. unbelievable
Date published: 2023-05-17
Rated 5 out of 5 by Deon M from Great Device Great device, It was just what we were looking for
Date published: 2022-02-14
Rated 5 out of 5 by tuttleman2 from Excellent calibration tool! I am a instrument calibration technician for a process engineering firm. I test and calibrate hundreds of in process pressure devices per year. The 719 Pro has been a true help to my productivity and has saved my hand from wearing out, when you do 30 to 50 pressure devices in a day it really helps to have the electric pump. I have even been amazed at the life of the batteries.
Date published: 2019-08-15
Rated 2 out of 5 by alcontrast from I wanted to like this and in some ways I still do. The features of this pressure calibrator are great and the ease of use is excellent; however... It was always frustrating because it would sometimes hold pressure and other times it wouldn't. In those cases my applied pressure would be steadily decreasing which made calibrations difficult or impossible. It was sent back to Fluke for repair once and the issue was not resolved. I got around the issue by purchasing a Fluke 750P05 pressure module and a hand pump which worked great until two weeks ago when I was on a jobsite and the connection point where the pressure module plugs into the 719PRO came loose and was coming out of the 719PRO when I attempted to unplug the cable. I attempted to secure the connection points by putting a spacer over the unused connection point and holding it in place with duct tape but later that day my pressure module was losing connection to the 719PRO when plugged in. I'm now planning to send it back to Fluke for repair a second time in I think 4 years of ownership and I only use the calibrator several times a month.
Date published: 2019-02-09
Rated 4 out of 5 by jasonsprigg from good intrument works very well. a couple of minor improvements would be to ad ft h2o as a unit and to have a port for an ac adapter in addition to the battery pack.
Date published: 2017-11-01