RPM4 Reference Pressure Monitor

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 119.37ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • No image available

Key Features

  • Rugged nigh precision reference pressure monitor. Uncertainty as good as +/- 0.008% reading
  • Independent quartz reference pressure transducer modules (Q-RPTs) with individual self-defense systems (SDS™)
  • Ranges from 15 kPa (2.2 psi) compound gauge up to 280 MPa (40,000 psi)
  • RS232 and IEEE-488 communications,battery pak available.
  • Flash memory for simple and free embedded

Product overview: RPM4 Reference Pressure Monitor

RPM4 Reference Pressure Monitor is different from traditional pressure monitors. State-of-the-art performance from very low pressure to 280 MPa (40,000 psi)… advanced on-board features… compact and rugged… full local and remote communications… RPM4 is the perfect solution in a wide variety of high end pressure calibration, testing and measurement applications.

Infinite Ranging™ and AutoRange™


Infinite Ranging gives RPM4 Reference Pressure Monitor unprecedented versatility in adapting to the specific range of operation. With the easy-to-use AutoRange function, a few simple key strokes or a single remote command string at the start of a test adapt every feature of the pressure monitor to optimize it for the range to be covered. Just enter the maximum pressure and the measurement mode. AutoRange then:

  • Selects and activates the most appropriate Q-RPT to cover the specified range and measurement mode.
  • Sets the pressure unit of measure. • Activates absolute, gauge or compound gauge measurement.
  • Adjusts display resolution to the appropriate level for the range.
  • Adjusts overpressure alarms to the actual range of operation.
  • Reduces measurement uncertainty proportionally to the selected range (premium class Q-RPTs only).


Note: The use of RPM4’s Infinite Ranging and AutoRange feature is recommended to optimize operation for a specific range but is not required to obtain “% of reading measurement specifications.

SDS™ Q-RPT self defense system


All Q-RPT modules up to 7 MPa (1 000 psi) include the unique Self Defense System™ (SDS). SDS valves automatically isolate and vent the module's Q-RPT when it is not in use or an overpressure is about to occur. With SDS, any Q-RPT module can be left connected to pressure up to 10 MPa (1 500 psi) without needing to isolate or disconnect it.

Advanced on-board functions


RPM4 pressure monitors provides a variety of advanced on-board pressure data functions including:

  • Special data such as pressure average over time, rate of change, hi/lo, freeze, deviation from set point.
  • Differential mode directly measures the difference between two Q-RPTs including taring at the line pressure.
  • Parallel measurement uses two Q-RPTs redundantly as one.
  • Leak check measures average pressure rate of change over a user set time period.
  • AutoTest automates calibration routines with tolerance testing and data logging.

Quartz reference pressure transducer (Q-RPT) modules


RPM4's outstanding pressure measurement specifications are made possible by Fluke Calibration’s exclusive quartz reference pressure transducer (Q-RPT) modules.

Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to optimize the metrological characteristics needed in a transfer standard. Standard and premium class Q-RPT modules are available to best fit your performance and budgetary requirements.

A unique dynamic compensation for atmospheric pressure system uses an independent on-board barometer to provide seamless switching between absolute, gauge and compound gauge modes at any time. The barometer is used only to measure the small variations in atmospheric pressure that occur during gauge mode operation so its absolute error and drift over time do not contribute to measurement uncertainty. Q-RPT modules offer the advantages of:

  • % of reading measurement uncertainty with AutoRange span turndown available
  • Negligible warm up time
  • No gas species dependence
  • Quartz element isolated from test medium
  • Low sensitivity to orientation


Q-PRTs and ranges

 


Q-RPT Designation

SI Version

US Version

Measurement MODE(s) Supported

Operating Media

SDSTM Self Defense System
 Maximum Range [kPa] Absolute Maximum Range [kPa] Gauge Maximum Range [psi] Absolute Maximum Range [psi] Gauge
A280M-L280 000280 00040 00040 000
Absolute, Gauge and Compound Gauge

Gas Stndard
Oil available

Not available
A200M-L200 000200 00030 00030 000
A140M-L140 000140 00020 00020 000
A100M-L100 000100 00015 00015 000
A70M70 00070 00010 00010 000
Gas Standard
Oil available
 Gas only
A40M40 00040 000 6 000 6 000
A20M20 00020 000 3 000 3 000
A14M14 00014 000 2 000 2 000
A10M10 00010 000 1 500 1 500
Included
A7M7 0007 000 1 000 1 000
A3.5M3 5003 500 500 500
Gas only
A2M2 0002 000 300 300
A1.4M1 4001 400 200 200
A700K700700 100 100
A350K350250 50 35
A200K200100 30 15
A160K16060238
A100K11010 16 1.5
BA100K1110
--- 
16
---
G200K
---
200 
---
30
Gauge only
G100K
---
100 
---
15
BG15K2
---
15 
---
2.2
G15K
---
15 
--- 
2.2


1 BA100K is a barometer with a low point of 70 kPa (10 psia).
2 BG15K is bidirectional gauge from - 15 to + 15 kPa (- 2.2 to + 2.2 psi).

Compatible with PPC4 Automated Pressure Controller


RPM4 can be used as an external reference pressure measurement device for a Fluke Calibration PPC4, fully automated, pressure controller/calibrator. One RPM4 can be connected to PPC4 by 9-pin RS232 cable. The RPM4's Q-RPT(s) become part of the PPC4 system and are managed by the PPC4 transparently to the user. There is only one test connection for the PPC4 system's full range of operation.

Specifications: RPM4 Reference Pressure Monitor

General
Power Requirements85 to 264 VAC, 50/60 Hz,
25 VA max and 12 VDC @ 9 Ahr
Battery/Charger:100 to 240 VAC, 50/60 Hz 
Normal Operating Temperature Range15 to 35 °C
VibrationMeets MIL-T-28800D
Weight (Typical)5 kg (11 lb)
Dimensions10 cm H x 22.7 cm W x 24 cm D (3.9 in. x 8.9 in. x 9.5 in.)
Battery/Charger:8 cm H x 22.5 cm W x 20 cm D (3.1 in. x 8.9 in. x 7.9 in.)
Communications PortsRS232 (COM1, COM2), IEEE-488.2
Operating ModesAbsolute, gauge, compound gauge, differential
Pressure RangesVacuum to 280 MPa (40,000 psi)
Operating MediaQ-RPTs lower than A7M Gas only
All others Either gas or oil
CalibrationNVLAP accredited
Pressure ConnectionsUp to A70M: 1/8 in. NPT F
Above A70M: DH500 (equivalent to AE250C) 
CE MarkAvailable, must be specified
Measured pressure (Q-RPT)
Warm Up Time30 minute temperature stabilization recommended from cold power up
ResolutionTo 1 ppm, user adjustable
Predicted One Year Stability1± 0.005 % of reading all ranges and classes
Precision2Q-RPTs up to A14M (2,000 psi)
Standard Class:± 0.008 % of reading, or 0.0024% of Q-RPT span, whichever is greater4
Premium Class:± 0.005 % of reading, 0.0015% of AutoRanged span or 0.0005% of Q-RPT span, whichever is greater5
Measurement Uncertainty3Q-RPTs up to A12M (2,000 psi)
Standard Class:± 0.010 % of reading or 0.0030% of Q-RPT span, whichever is greater4
Premium Class:± 0.008 % of reading, 0.0024% of AutoRanged span, or 0.0007% of Q-RPT span, whichever is greater
Precision2Q-RPTs A20M TO A140M (3,000 to 20,000 psi)
± 0.012 % of reading or 0.0036% of Q-RPT span, whichever is greater4
Measurement Uncertainty3Q-RPTs A20M TO A140M (3,000 to 20,000 psi)
± 0.013 % of reading or 0.0039% of Q-RPT span, whichever is greater
Precision2QRPT’s A200M to A280M (30,000 to 40,000 psi)
± 0.015 % of reading or 0.0045% of Q-RPT span, whichever is greater
Measurement Uncertainty3QRPT's A200M to A280M (30,000 to 40,000 psi)
± 0.018 % of reading or 0.0054% of Q-RPT span, whichever is greater4
  1. Predicted one year stability limit (k=2) assuming regular use of AutoZero function. Absolute mode predicted one year stability without use of AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading). QRPT’s A200MN to A280M (30,000 to 40,000 psi).
  2. Combined linearity, hysteresis and repeatability. Add ± 1 Pa (0.00015 psi) in gauge mode with an Axxx Q-RPT for the resolution and short term stability of the on-board barometer.
  3. Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year stability, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.
  4. % of reading value times measured pressure from 100 to 30 % of Q-RPT span. Under 30 % of Q-RPT span, % of reading value times 30 % of Q-RPT span. For example, if the QRPT is a Standard A160K, the Measurement Uncertainty in pressure is 0.010% times the measured pressure to 48 kPa (160 kPa span x 30%) and 0.0048 kPa (160 kPa span x 30% x 0.01%) under 48 kPa.
  5. % of reading value times measured pressure from 100 to 30 % of AutoRanged span. Under 30% of AutoRanged span, % of reading value times 30% of AutoRanged span. If AutoRanged span is less then 30% of maximum Q-RPT span, % of reading values times measured pressure, or % of reading times 9% of Q-RPT span, whichever is greater. For example, if the Q-RPT is a Premium A160K and AutoRanged span is 160 kPa, the Measurement Uncertainty in pressure is measured pressure x 0.008% to 48 kPa (160 kPa AutoRanged span x 30%) and 0.0038 kPa (160 kPa span x 30% x 0.008%) under 48 kPa. If the AutoRanged span is 100 kPa (greater than 30% of 160 kPa maximum Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008% to 30 kPa (100 kPa AutoRanged span x 30%) and 0.0025 kPa (100 kPa span x 30% x 0.008%) under 30 kPa. If the AutoRanged span is 30 kPa (less than 30% of the 160 kPa maximum Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008% to 14.4 kPa (160 kPa maximum Q-RPT span x 9%) and 0.0012 kPa (160 kPa maximum Q-RPT span x 9% x 0.008%) under 14.4 kPa. For GXXX ranges, the total uncertainty is expanded to 0.015% reading or 0.0045% of Q-RPT span, whichever is greater when used outside of the altitude range of -90 to Ordering information 900 meters (-300 to 3000 feet).
  6. Premium class not available on G100K and G200K ranges.

Models: RPM4 Reference Pressure Monitor

RPM4 mhhhac/mlllac
Reference Pressure Monitor

Buy it
Where:
mhhhac indicates the Hi Q-RPT designation.
c indicates Q-RT class (s for Standard, p for Premium)

mlllac indicates the Lo Q-RPT designation and class. Leave blank if there is no Lo Q-RPT.

See Q-RPT and ranges table under Features for available Q-RPTs.
RPM4 04
-1 US units version, -2 SI units version

Buy it
RPM4 05
CE mark

Buy it
RPM4 06
Special calibration

Buy it
RPM4 07
Special test fluid, Hi Q-RPT (specify fluid)

Buy it
RPM4 08
Special test fluid, Lo Q-RPT (specify fluid)

Buy it
RPM4 09
-1 Special configuration, air data (A160K/A160K, A350K/A160K only)

Buy it
RPM4-LP
Low Pressure Monitor, -15 to 15 kPa (-60 to 60 inH2O)

Buy it
3990-803
Manual Pressure Control to 20 MPa (3000 psi)

Buy it
RPM4-BAROM-1
Reference Pressure Monitor

Buy it
Improved barometric pressure measurement, for air buoyancy correction and absolute pressure by the addition of atmosphere.
RPM4
Reference pressure monitor for external Q-RPTs and/or absolute mode AutoZ.

Buy it
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 126.26ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 27.85ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat