5649/5650 | Type R and Type S Thermocouple Standards

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.22ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 5649 / 5650 Type R and Type S Thermocouple Standards

Key Features

  • Type R and S Thermocouples.
  • Platinum and platinum-rhodium alloy.
  • Temperature range of 0 °C to 1450 °C.
  • Uncertainties as good as 0.15 °C over most of that range.
  • Calibrated at four fixed points (Sn, Zn, Al, Ag) and then extrapolated to 1450 °C.
  • Four version avaialbe, 20 and 25 inch lengths with and without CJC.

Product overview: 5649/5650 | Type R and Type S Thermocouple Standards

The measuring junction of both the 5649 and the 5650 is encased in a 0.25-inch (6.35 mm) alumina sheath that can be ordered in lengths of 20 or 25 inches (50.8 or 63.5 cm) to fit the specific requirements of your application. A reference, or “cold," junction may also be ordered. The reference junction uses a stainless steel sheath and is 8.25 inches long (21 cm) by 0.188 inches in diameter (4.8 mm). The thin diameter minimizes the immersion depth needed, but the extra length ensures you can get all the immersion you like.

Special tin-plated, solid-copper connecting wires with ultra-low EMF properties are used to help retain the integrity of your measurement junction where the probe attaches to your micro voltmeter or Hart Black Stack.

Each probe comes with an individual calibration with fixed-point standards to reduce uncertainties to ± 0.15 °C up to 962°C, ± 0.25 °C up to 1100 °C, and increasing linearly to ± 2.0 °C at 1450 °C.

The probe assembly can be easily disassembled for performing your own bare-wire calibrations.

Specifications: 5649/5650 | Type R and Type S Thermocouple Standards

Specifications
Range0 °C to 1450 °C
TypePlatinum/13 % Rhodium vs. platinum (type R)
Platinum/10 % Rhodium vs. platinum (type S)
CalibrationFixed point calibration uncertainties
(k=2): ± 0.15 °C up to 962 °C,
increasing linearly to ± 2.0 °C at 1450 °C
Hot Junction
Sheath Dimensions
6.35 mm (0.25 in) diameter;
see Ordering Information for lengths
Reference Junction Sheath Dimensions4.8 mm dia. x 210 mm long (0.188 x 8.25 in)
Long-Term Stability± 0.5 °C to 1100 °C
± 2.0 °C to 1450 °C (over one year depending on usage)
Short-Term Stabilities± 0.2 °C to 1100 °C
± 0.6 °C to 1450 °C
ImmersionAt least 152 mm (6 in) recommended
Protective CaseModel 2609 case included
Weight1 kg (2 lb)

Models: 5649/5650 | Type R and Type S Thermocouple Standards

5649 / 5650 Type R and Type S Thermocouple Standards
Type R and Type S Thermocouple Standards

Buy it
5649-20-X
Type R TC, 508 mm (20 in)

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5649-20CX
Type R TC, 508 mm (20 in), with reference junction

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5649-25-X
Type R TC, 635 mm (25 in)

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5649-25CX
Type R TC, 635 mm (25 in), with reference junction

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5650-20-X
Type S TC, 508 mm (20 in)

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5650-20CX
Type S TC, 508 mm (20 in), with reference junction

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5650-25-X
Type S TC, 635 mm (25 in)

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
5650-25CX
Type S TC, 635 mm (25 in), with reference junction

Buy it
X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.24ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat