Search results

Only search for:
Found 100 results containing the words:<front>
  • Calibrating an oscilloscope for trigger operation

    Learn how to effectively calibrate your oscilloscope's trigger operation with our detailed guide. Enhance measurement accuracy and reliability for better outcomes.

    Article
  • Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp

    The Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp, True-RMS CAT III 1500V is ideal for solar power systems, ensuring safety and accuracy.

    Products
  • Fluke 283 FC CAT III 1500V Digital Multimeter

    The Fluke 283FC Solar Digital Multimeter, True-RMS CAT III 1500V is ideal for solar power systems, ensuring safety and accuracy.

    Products
  • OPG1 Hydraulic Pressure Generator / Controller

    Fluke Calibration's OPG1-30000 provides an alternative for generating and adjusting high liquid pressures in calibration and test systems.

    Products
  • 8558A 8.5 Digit Multimeter

    The 8558A 8.5-digit multimeter offers 5 mega-samples-per-second high resolution digitizing for system automation in labs and manufacturing test environments.

    Products
  • 280 Series Waveform Generators

    280 series waveform generators from Fluke Calibration are highly sophisticated 12-bit arbitrary generators capable of recreating virtually any waveform.

    Products
  • 5790A AC Measurement Standard

    5790A AC measurement standard is compatible with current shunts & is designed for the most demanding calibration applications. Request a product quote today!

    Products
  • Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0)

    Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.iso) Documents: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.pdf) MET/TEAM 3.0.0 ReadMe (.pdf) MET/CAL 10.2.0 ReadMe (.pdf) MET/TEAM Installation Guide (Updated for version 3.0) (.pdf) Current MET/TEAM Customers: What you need to know prior to updating The MET/TEAM version 3.0.0 and MET/CAL version 10.2.0 release is a a major update to MET/TEAM and MET/CAL software. This update includes new features, improvements, bug fixes,...

    Article
  • MET/TEAM® v3.3.0 and MET/CAL® v11.0.0 Software Trial

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso) Documents: MET/CAL 10.5.0 Readme (.pdf) MET/TEAM Installation Guide (.pdf) MET/TEAM 3.1.1 Readme (.pdf) Update Instructions for MET/TEAM 3.1.1 and MET/CAL 10.5.0 (.pdf) This update is not for MET/CONNECT Customers.  Current MET/TEAM Customers: What you need to know prior to updating The MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor...

    Article
  • PPC4 Pressure Controller / Calibrator

    Fluke Calibration offers pressure transducer calibration, and portable pressure calibrators that are rugged, reliable, versatile, and include flash memory for software updates.

    Products
  • COMPASS for Pressure Calibration Software Download/Upgrade

    COMPASS for Pressure Basic (.exe) Additional Downloads: COMPASS for Pressure Basic, Demo (.exe) COMPASS for Pressure Basic, Upgrade (.exe) COMPASS for Pressure Enhanced (.exe) COMPASS for Pressure Enhanced, Demo (.exe) COMPASS for Pressure Enhanced, Upgrade (.exe)   TITLE VER USE WITH DOCUMENTS COMPASS® for Pressure™ 5.2.10 2024.05.21 FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456, 2271A,...

    Article
  • Update: MET/CAL version 10.2.2 for MET/TEAM version 3.0.0

    Update: MET/CAL version 10.2.2 for MET/TEAM version 3.0.0 (.zip) This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available with the MET/CONNECT 1.2.0 installer. Current MET/TEAM Customers: MET/CAL version 10.2.2 release is an update to previous MET/CAL software. This update includes bug fixes and minor updates. Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files....

    Article
  • RPM4-E-DWT v1.00c Embedded Software

    RPM4-E-DWT v1.00c Embedded Software (.bin) TITLE VER USE WITH E-DWT 1.00c 2014.08.06 RPM4-E-DWT Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it...

    Article
  • RPM4-E-DWT A70M/A7M-AF Embedded Software

    RPM4-E-DWT A70M/A7M-AF Embedded Software (.bin) TITLE VER USE WITH NOT FOR USE WITH RPM4-E-DWT A70M/A7M-AF™ 1.00c 2012.05.01 RPM4-E-DWT-AF Do NOT use with NON "-Af" RPM4-E-DWT Models! Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port...

    Article
  • RPM4-AF v1.00b Embedded Software

    RPM4-AF v1.00b Embedded Software (.bin) TITLE VER USE WITH NOT FOR USE WITH RPM4-AF™ 1.00b 2010.09.22 RPM4-AF Do Not use with RPM4, RPM4-AD or RPM4-EDWT or RPM4 in ADCS! Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC,...

    Article
  • RPM4-AD v1.00f Embedded Software

    RPM4-AD v1.00f Embedded Software (.bin) TITLE VER USE WITH NOT FOR USE WITH RPM4-AD™ 1.00f 2010.12.28 RPM4-AD Do NOT use with NON "-AD" (Air Data) RPM4 Models Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox....

    Article
  • Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso) This update is not for MET/CONNECT Customers.  Current MET/TEAM Customers: What you need to know prior to updating The MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates. You may upgrade from either version 3.0.0 or 3.1.0 directly to version 3.1.1. Upgrading from version 3.0.0 or 3.1.0 of MET/TEAM will not require you to re-request...

    Article
  • PPCH-G v1.02k Embedded Software

    PPCH-G v1.02k Embedded Software (.bin) TITLE VER USE WITH PPCH-G™ 1.02k 2023.11.08 PPCH-G Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it requires...

    Article
  • PPCH-G v1.02f Embedded Software

    PPCH-G v1.02f Embedded Software (.bin) TITLE VER USE WITH PPCH-G™ 1.02f 2012.04.04 PPCH-G Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it requires...

    Article
  • PPCH 1.01n Embedded Software

    PPCH 1.01n Embedded Software (.bin) TITLE VER USE WITH PPCH™ 1.01n 2013.07.22 PPCH Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it requires specific...

    Article
  • PPC4E v1.2.6.15 Embedded Software

    PPC4E v1.2.6.15 Embedded Software (.bin) TITLE VER USE WITH PPC4E™ 1.2.6.15 PPC4E Instructions: Download the file by clicking on "PPC4E v1.2.6.15.bin". Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number...

    Article
  • PPC3 v1.03d Embedded Software

    PPC2-AF v1.01e Embedded Software (.bin) TITLE VER USE WITH PPC3™ 1.03d 2011.10.21 PPC3 (including -AF models) Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. The updating of embedded software should...

    Article
  • 96040A Low Phase Noise Reference Source

    The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.

    Products
  • 9118A Thermocouple Calibration Furnace

    The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C.

    Products
  • 9114, 9115A, 9116A Freeze-point furnaces

    9114, 9115A, 9116A Freeze-point furnaces from Fluke Calibration are very stable & can be used to maintain metal fixed-points for hours to calibrate your SPRT.

    Products
  • PG7000 Ver 2.07h Embedded Software

    PG7000 Ver 2.07h Embedded Software (.bin) TITLE VER USE WITH PG7000™ 2.07h All PG7000 Series models Instructions: -Ver 2.02x and 2.03x Users You can upgrade directly to this version with no special considerations. -Ver 2.01x Users Ver 2.02 is a major revision which should be accompanied by hardware changes. -Ver 1.0x Users Ver 2.01 is a major revision which should be accompanied by hardware changes. Contact a Fluke Calibration Authorized Service Center for additional information. Download...

    Article
  • molbox1+ or molbox1+S v6.01 Embedded Software

    molbox1+ or molbox1+S v6.01 Embedded Software (.bin) TITLE VER USE WITH molbox1+/molbox1+S™ 6.01 2016.12.16 molbox1+/molbox1+S TITLE VER USE WITH molbox1+/molbox1+S™ 6.01 2016.12.16 molbox1+/molbox1+S This flash is intended ONLY for molbox1+ or molbox1+S with the Fluke Calibration logo: on the front panel, serial number 2000 and above. Attempted use on any other molbox will result in an inoperable molbox unless the molbox1 hardware is upgraded to a molbox1+. For a molbox1...

    Article
  • molbox1 v5.41 Embedded Software

    molbox1 v5.41 Embedded Software (.bin) TITLE VER USE WITH molbox1™ 5.41 2016.12.16 molbox1 TITLE VER USE WITH molbox1™ 5.41 2016.12.16 molbox1 Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox....

    Article
  • MFC-CB v1.00b Embedded Software

    MFC-CB v1.00b Embedded Software (.bin) TITLE VER USE WITH MFC-CB™ 1.00b 2005.10.19 MFC-CB TITLE VER USE WITH MFC-CB™ 1.00b 2005.10.19 MFC-CB Instructions: Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox....

    Article
  • COMPASS® for Pressure Version 3 Release Notes

    Download COMPASS® for PressureVersion 3 Releases3.00.43 (SP1) (2011.02.11)ADDCP-802Support PG7000 and PG9000 models that respond with FLUKE as the manufacturer.CHGCP-793An automated PG7000/PG9000 system with a PPC and AMH will use ATM as the minimum pressure when exercising in a test that is run in Absolute by ATM.3.00.42 (SP1) (2010.07.07)ADDCP-689Support alternate units of measure and temperature references for the Piston Cylinder effective area.ADDCP-775Added new instruments to the default database.CHGCP-786When...

    Article
  • 1560 Black Stack Thermometer Readout

    Fluke Calibration’s Black Stack thermometer readout is one of the most versatile, cost-effective & accurate readouts in the world. Learn more.

    Products
  • 5 Electrical Problems That Require a Power Quality Meter

    There are five vital measurements that could be causing problems in your electrical distribution system that you may be missing even with a True-rms digital multimeter. While the digital multimeter is a valuable and indispensable tool for the electrical professional, it does have limitations. A multimeter may be able to alert you to one of these five issues, but be prepared to use a power quality analyzer to dig in further and uncover these hidden potential problems. Those measurements are: 1. Harmonic...

    Article
  • Guide to Using FieldSense in the 377 FC and 378 FC Clamp Meter

    Best ways to use the 377 FC and 378 FC clamp meter, how FieldSense technology works and ideal applications for front-line technicians and electricians.

    Article
  • How to use the power quality indicator on the 378 FC clamp meter

    Detect basic 3 phase power quality issues with the versatile Fluke 378 FC clamp meter for industrial electricians. Increase productivity and safety without test leads.

    Article
  • Safe Electrical Panel Measurements with a Measurement Window

    The need to measure three-phase electrical systems has become increasingly important, especially for simple energy surveys, more complex power quality troubleshooting, or overall electrical performance studies on individual electrical equipment such as transformers and motors. However, taking three-phase measurements can be dangerous as you need to open electrical panels and put on proper personal protective equipment (PPE). The top risks can carry severe penalties, whether it's personal injury or...

    Article
  • Oscilloscope vs multimeter: choosing the right tool for testing and troubleshooting

    The difference between an oscilloscope and a digital multimeter (DMM) is simply stated as pictures vs. numbers. Learn more, including when to use each.

    Article
  • How to choose the right clamp meter for your job

    Fluke’s assortment of clamp meters has been engineered to address a wide variety of needs, from routine tasks to specialty projects.

    Article
  • From Test Tools to Face Shields: How Fluke is Adapting to Assist in the Fight Against COVID-19

    Learn how Fluke shifted resources to meet the global demand for PPE face shields in the fight against COVID-19.

    Article
  • How calibration improves optimization

    Learn which calibration tools are best for improving optimization and quality in process manufacturing plants including chemical processing, nuclear power, pharmaceutical, pulp and paper.

    Article
  • Wind Effects on Thermal IR Images

    Understand the effects of wind on thermography. Forced convection can come in the form of wind, a fan or even a pump, and the result of this forced convection will affect the target temperature.

    Article
  • What causes a transformer to overheat?

    Transformer infrared inspections can show you abnormal thermal overload patterns in cooling tubes which can be escalated for troubleshooting.

    Article
  • Renewable energy: Maintenance and health of battery storage systems

    Importance of investing in battery storage systems health and maintenance.

    Article
  • A closer look at germanium lenses for thermal cameras

    Learn how to choose the right IR lens for your thermal camera and why germanium is used in thermal camera lenses.

    Article
  • Fluke 1736 and 1738 Three-Phase Power Quality Loggers

    Versatile, three-phase Fluke Connect-compatible power loggers for conducting energy, load and power quality studies.

    Products
  • Fluke Norma 6000 Series Portable Power Analyzers

    Get accurate, precise measurements. Portable, lightweight power analyzer with 10 hours of battery life.

    Products
  • The 7 Best Tools for Electricians in 2024

    We recently asked electricians what they considered their top 5 essential tools—there were a few ties, so we’re sharing their top 7.

    Article
  • Fluke CPAK Magnetic Hanging Tool Pouch

    Keep your tools together and within reach in your tool bag.

    Products
  • Preventive maintenance vs predictive maintenance vs proactive maintenance

    What is the difference between preventive maintenance vs predictive maintenance programs? Learn how to move from a reactive to a proactive maintenance program.

    Article
  • Fluke PQ400 Electrical Measurement Window

    The Fluke PQ400 gives you access to the critical power quality and energy data you need, all while decreasing testing time and helping you to maintain safety.

    Products
  • How Adjustable Speed Drives Affect Power Distribution

    Adjustable speed drives (ASDs) can be both a source and a victim of poor power quality.

    Article
  • Troubleshooting Power Harmonics: Basic Troubleshooting Using Multimeters and Current Clamps

    This application note details the procedures for using Fluke power quality analyzers for average watt measurements and converting those to watt-hours.

    Article
  • CPS-2270-20M-HC20

    Contamination Prevention System 20 MPa (3000 psi), HC20 Test Port Connection

    Products
  • Case study: Network Hub Failure

    Ever fixed something and still not solved the problem? Sometimes multiple deficiencies can all cause the same symptoms.

    Article
  • What you need to know about emissivity and infrared energy

    .video-container { position: relative; padding-bottom: 56.25%; padding-top: 30px; height: 0; overflow: hidden; } .video-container iframe, .video-container object, .video-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; } Using a Fluke infrared camera, it's important to understand the relevance of emissivity to temperature measurement calculation. Transcript: All objects radiate infrared energy. The quantity of energy radiated is based on the actual surface temperature...

    Article
  • What kind of thermal imager focus system do you need?

    In infrared imaging, precise focus means a lot more than just getting a clear image. It can mean the difference between catching or overlooking a problem.

    Article
  • Top 10 Changes to 2018 NFPA 70E Safety Standards for Electricians

    With the recent release of the 2018 edition of the NFPA 70E standard, many users are finding it challenging to interpret what it says and prioritize where they should focus their attention. The short answer is that the entire 70E standard is important; not just one chapter, article or section.

    Article
  • Case study: Remote power monitoring helps prevent football power failures

    Filmwerks International is one company that has implemented a better way to monitor utility power for their backup UPS systems and generators

    Article
  • How to find harmonics in electrical systems

    Power quality is an estimate of how stable the electrical system is, often this is described as “power quality health.” This is measured on three-phase electrical systems using instrumentation that considers several variables. Troubleshooting power quality issues will help your facility save money by optimizing energy use and protect equipment from future damage. The first step to evaluating power quality is to capture data from equipment, infrastructure, and the service panel. The primary effects...

    Article
  • Fluke 1535 and 1537 Insulation Resistance Tester and Megohmmeters

    The Fluke 1535 and 1537 2,500 V Insulation Resistance Testers for industrial and solar applications

    Products
  • PRESS RELEASE: New Fluke electrical loggers can help reduce facilities’ energy costs

    The Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers identify opportunities for critical energy savingsEVERETT, Wash., Feb. 16, 2017 – One of the most significant costs at industrial facilities is energy. While many managers view energy as an unavoidable expense, in reality it is a variable cost that can be monitored and managed, significantly improving the bottom line.The new Fluke 1732 and 1734 Three-Phase Energy Loggers are powerful tools that are designed to more easily identify sources...

    Article
  • From screwdrivers to testers: Vibration analysis comes of age

    Most machines have rotating parts, and rotating parts vibrate. Measuring how and how much those parts vibrate can tell you a lot about the health of a machine.

    Article
  • Make better energy consumption decisions

    The Fluke 1738 Advanced Three-Phase Power Logger automatically captures and logs more than 500 power quality parameters to give electricians and technicians more visibility into the data needed to make better power quality and energy consumption decisions.

    Article
  • Case study: Circuit board hot spots

    Ensuring that a soon-to-be-launched prototype printer works without any hiccups when it reaches consumer hands is an already daunting task. But when you're doing this for the world's largest printer manufacturer, the task takes on an entirely different magnitude.

    Article
  • Fluke 1586A Super-DAQ Precision Temperature Scanner

    The most accurate and flexible temperature data acquisition system on the market.

    Products
  • Fluke Calibration 1502A/1504 Thermometer Readout

    The 1502A and 1504 reference thermometers will read RTDs, PRDs, and thermistor sensors. Primary temperature standards, secondary temperature standards, fixed-point cells, water triple points, SPRTs, calibration baths, dry-block calibrators and temperature metrology training can also be found on this site.

    Products
  • Inspect moving machinery by putting the 'freeze' on

    New stroboscope helps frontline mechanical troubleshooting teams precisely measure machine rotation and oscillation without shutting down the equipment.

    Article
  • Fluke t3000 FC Wireless Temperature Module

    The Fluke CNX™ t3000 K-Type Wireless Voltage Module lets you troubleshoot HVAC systems faster, safer, easier. Record and view readings remotely.

    Products
  • Fluke TiS75 Infrared Camera

    With 320x240 resolution and manual focus, the TiS75 produces professional quality images to make it easy to both see and solve the problem.

    Products
  • Fluke v3000 FC Wireless AC Voltage Module

    A fully functional AC voltage meter that wirelessly relays AC voltage measurements to other Fluke Connect® enabled master units

    Products
  • Fluke v3001 FC Wireless DC Voltage Module

    A fully functional DC voltage meter that wirelessly relays DC voltage measurements to other Fluke Connect® enabled master units

    Products
  • Fluke 1750-TF Three-Phase Power Quality Recorder

    Record three-phase power quality monitoring for power quality disturbances with the new Fluke 1750 Power Recorder and the Fluke Power Analyze software.

    Products
  • Fluke 1750/B Three-Phase Basic Power Quality Recorder

    Record three-phase power quality monitoring for power quality disturbances with the new Fluke 1750 Power Recorder and the Fluke Power Analyze software.

    Products
  • Fluke a3002 FC Wireless AC/DC Current Module

    AC/DC current module that wirelessly relays measurements from current clamp accessories to other Fluke Connect® enabled master units

    Products
  • Fluke a3000 FC Wireless AC Current Clamp Module

    A fully functional true-rms current clamp meter that wirelessly relays measurements to other Fluke Connect® enabled master units

    Products
  • 53 II Temperature Logging Digital Thermometer

    The Fluke 53 II single input digital thermometer with data logging offers fast response and laboratory accuracy (0.05% + 0.3 °C) in a rugged, handheld test tool.

    Products
  • Fluke 1750 Three-Phase Power Quality Logger

    Record, monitor and evaluate power quality disturbances with the Fluke 1750 including voltage, current, harmonics, transients, waveforms and flicker.

    Products
  • Fluke 805 Vibration Meter

    Forget the pens. Think METER. The Fluke 805 is not a vibration pen; it's a meter. A Fluke meter that eliminates the confusion of vibration screening and provides reliable measurements you can trust to make critical go or no-go maintenance decisions.

    Products
  • Fluke 820-2 LED Stroboscope

    Identifying the running speed of rotating equipment can be difficult, but the Fluke 820-2 LED Stroboscope simplifies the process allowing you to perform stop motion diagnostics without actually stopping, or making contact, with the machine you are working on.

    Products
  • How to measure electricity from a safe distance

    How to measure electricity from a safe distance

    Article
  • Understanding Vibration Monitoring and Analysis

    Vibration testing for condition-based maintenance, to reduce costs and production losses. Mechanics of testing, analyzing roller bearing faults.

    Article
  • Testing your test leads

    Checking your test leads to make sure they are in good condition and rated for the job at hand is the best insurance for accuracy and safety

    Article
  • Moving from reactive to predictive maintenance

    Fluke News Plus Predictive Maintenance Archive Articles

    Article
  • El nuevo medidor de vibraciones Fluke 805 FC es la última incorporación a Fluke Connect, el sistema inalámbrico de herramientas de prueba y medición más grande del mundo

    Fluke Corp. introduces the Fluke® 805 FC Vibration Meter, a portable multifunction vibration screening tool that provides quantifiable information on the bearing and overall health of motors and other rotating equipment, and shares that data in real time via Fluke Connect®. The Fluke 805 FC is ideal for frontline mechanical troubleshooting teams that need reliable and repeatable measurements of rotating equipment to make imperative go/no-go maintenance decisions.

    Article
  • Retirada del adaptador de potencia BC1735/EELV

    Fluke is voluntarily recalling certain BC1735/EELV Power Adapters which are used with the Fluke 1735 Power Logger.

    Article
  • Chasing "ghost" trips in GFCI-protected circuits

    This issue of "Solid Ground" talks about ground fault circuit interrupters (GFCIs), why they are necessary, and how to troubleshoot GFCI-protected circuits.

    Article
  • Earth ground testing for mine sites with Fluke 1625

    All mine sites have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage or ground fault, the current would be able to find a safe path to earth or the neutral of the transformer.

    Article
  • Multimeter measurements on adjustable speed drives utilizing the new Fluke 87V DMM

    In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs).

    Article
  • Breaking new ground without breaking the loop

    Early reports from the field suggest that the new Fluke 772 and 773 Milliamp Process Clamp Meters may be game changers, breaking new ground for technicians in the HVAC controls industry. With the feature sets these meters offer, troubleshooting of the most common problems in modern control systems becomes a snap.

    Article
  • Have you ever wondered about the efficiency of your fireplace?

    Beyond the basics: Have you ever wondered about the efficiency of your fireplace?

    Article
  • A behind-the-scenes look at product innovation at Fluke

    Fluke News Plus Research Archive Articles

    Article
  • Using Non-Contact Tools to Stay Out of Harm's Way

    Limiting workers’ exposure to electrical hazards like arc flash or electrocution is a solid foundation for any electrical safety program. Combine that mindset with the right non-contact tools and more electrical workers will be kept out of harm’s way.

    Article
  • How to come home safely at the end of the day

    Electrical safety requirements for using digital multimeters per OSHA and NFPA 70E

    Article
  • Tough Places, Tough Tools

    Out on the job site, concrete finishers stand ready to shape wet ready-mix into a new stretch of highway. Mixer trucks are lined up at the concrete batch plant,waiting to take on their loads. But hold on—an electrical problem has shut down the plant. It's time to call Keithly Electric.

    Article
  • What is the relationship between oscilloscope bandwidth and waveform rise time?

    The formula can be stated in two ways, depending on what you're looking for. It is usually applied to the leading edge of a pulse in a dynamic system and is related to resistor-capacitor filter time constants and settling times.

    Article
  • Five problems you will never uncover with a digital multimeter

    The importance of investing in the right set of tools to monitor power quality issues, and prevent them in the future, can't be emphasized enough. Fluke offers an extensive range of excellent power meters and other power quality tools for troubleshooting, preventive maintenance, and long-term recording and analysis in industrial applications and utilities.

    Article
  • Case study: Texas power consultant keeps uninterruptible power supplies up and running

    Critical systems run smoothly with regular maintenance and reliable tools Everybody knows that consistent, dependable electrical power is critical to any plant's function. But perhaps even more critical is a reliable uninterruptible power supply (UPS) system. UPS systems are the silent partners that just sit and wait until there's a break in power. At that point, the UPS system is the most important system in the plant. It has to be ready to spring into action in milliseconds to keeps things running for anywhere from seconds to hours.

    Article
  • Improve your team productivity when working on variable air volume (VAV) systems

    In my role as a consultant and trainer, I spend a lot of time working with facility maintenance personnel. Recently I was recently given a formidable task by the maintenance leadership of the plant services shop of a large university.

    Article
  • Measuring air velocity with the Fluke 975 AirMeter™: Using the Velocity Probe

    Air velocity is a key parameter in evaluating airflow system performance. As part of basic testing, adjusting and balancing of HVAC air distribution systems, most HVAC technicians now use an anemometer to measure air velocity at grilles-registers-diffusers, within a duct, or in open spaces.

    Article
  • Troubleshooting web-based HVAC control system networks

    Scenarios showing how to prevent system failures and downtime caused by HVAC network problems.

    Article