Key features

  • Guided testing with graphical step-by-step connection diagrams
  • Preset measurement profiles reduce setup complexity
  • Built-in report writing capabilities 
  • Easily produce as-found and as-left troubleshooting reports
In stock
$9,388.99
Now with Care Plan options
FREE Shipping
30-day Returns
Product + Premium Care Plan
Premium Care Plan only (I already own the product)
No thanks

Product overview: Fluke MDA-550 Series III Motor Drive Analyzer

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

Simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results.

The Fluke MDA 550 Motor-Drive Analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying motor-drive troubleshooting. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, the MDA-550 has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence.

The MDA-550 is the ideal portable motor-drive analysis test tool and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.

  • Measure key motor-drive parameters including voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance and harmonics, voltage modulation, and motor shaft voltage discharges.
  • Perform extended harmonics measurements to identify the effects of low and high order harmonics on your electrical power system.
  • Conduct guided measurements for motor-drive input, DC bus, drive output, motor input and shaft measurements with graphical step-by-step voltage and current connection diagrams.
  • Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure.
  • Create reports quickly and easily that are perfect for documenting troubleshooting and collaborative work with others.
  • Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems.

The Fluke MDA-550 Motor Drive Analyzer uses guided test measurements to make analysis easier than ever

Drive input

Measure input voltage and current to quickly see whether values are within acceptable limits by comparing the drive’s nominal rated voltage to the actual supplied voltage. Then, check the input current to determine if the current is within the maximum rating and the conductors are suitably sized. You can also check whether the harmonic distortion is within an acceptable level by visually inspecting the waveform shape or by viewing the harmonics spec¬trum screen which shows both the total harmonic distortion and individual harmonics.

Voltage and current unbalance

Check the voltage unbalance at the input terminals so you can ensure the phase unbalance is not too high (> 6-8 %), and that the phase rotation is correct. You can also check the current unbalance, as excessive unbalance may indicate a drive rectifier problem.

Extended harmonic measurements

Excessive harmonics are not just a threat to your rotating machines but also to other equipment connected to the electrical power system. The MDA-550 provides the ability to discover the harmon¬ics of the motor-drive but can also discover the possible effects of inverter switching electronics. The MDA-550 has three harmonic ranges, 1st to 51st Harmonics, 1 to 9 kHz and 9 kHz to 150 kHz giving the ability to detect any harmonic pollution problems.

DC bus

In a motor-drive the conversion of AC to DC inside the drive is criti¬cal, having the correct voltage and adequate smoothing with low ripple is required for the best drive performance. High ripple volt¬age may be an indicator of failed capacitors or incorrect sizing of the connected motor. The record function can be used to check DC bus performance dynamically in the operating mode while a load is applied.

Drive output

Check the output of the drive focusing both on voltage to frequency ratio (V/F), and voltage modulation. When high V/F ratio measure¬ments are experienced, the motor may overheat. With low V/F ratios, the connected motor may not be able to provide the required torque at the load to sufficiently run the intended process.

Voltage modulation

Measurements of the Pulse Width Modulated signal are used to check for high voltage peaks which can damage motor winding insulation. The rise time or steepness of impulses is indicated by the dV/dt reading (rate of voltage change over time), this should be compared to the motor’s specified insulation. The measure¬ments can also be used to measure switching frequency to identify whether there is a potential issue with electronic switching, or with grounding, where the signal floats up and down.

Motor input

Ensuring that voltage is being supplied at the motor input termi¬nals is key, and the selection of cabling from drive to the motor is critical. Incorrect cabling selection can result in both drive and motor damage due to excessive reflected voltage peaks. Checking that the current present at the terminals is within the motor rating is important as over current condition could cause the motor to run hot, decreasing the life of the stator insulation which can result in the early failure of the motor.

Motor shaft voltage

Voltage pulses from a variable speed drive can couple from a motor’s stator to its rotor, causing a voltage to appear on the rotor shaft. When this rotor shaft voltage exceeds the insulating capac¬ity of the bearing grease, flashover currents (sparking) can occur, causing pitting and fluting of the motor bearing race, damage that can cause a motor to fail prematurely. The MDA-550 is supplied with carbon fiber brush probe tips that can easily detect the pres¬ence of destructive flashover currents, while the impulse amplitude and count of events will enable you to take action before failure occurs. The addition of this accessory allows you to discover poten¬tial damage without investing in expensive permanently installed solutions.

Step-by-step guided measurements ensure you have the data you need, when you need it

The MDA-550 is engineered to help you quickly and easily test and troubleshoot typical problems on three-phase and single-phase inverter type motor-drive systems. The on-screen information, and step-by-step setup guidance make it easy to configure the analyzer and get the drive measurements you need to make better main¬tenance decisions, fast. From power input to the installed motor, the MDA-550 provides the measurement capability for the fastest motor-drive troubleshooting.

What's in the box:

  • 1x BP 291 li-ion battery pack
  • 1x BC190 charger/power adapter
  • 3x VPS421 100:1 high voltage probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage probe
  • 3x i400s ac current clamp
  • 1x SVS-500 shaft voltage set (3x brush
  • Probe holder
  • Two-piece extension rod and magnetic base
  • Large size, protective carrying case with rollers (C437-II)
  • FlukeView-2 PC software (full version)
  • WiFi dongle (Part #4723989)

Specifications: Fluke MDA-550 Series III Motor Drive Analyzer

Measurement and Analysis Combinations
Test pointSub groupReading 1Reading 2Reading 3Reading 4
Motor drive input
Voltage and current
Phase-phaseV-A-HzV ac+dcA ac+dcHz 
V peakV peak maxV peak minV pk-to-pkCrest factor
A peakA peak maxA peak minA pk-to-pkCrest factor
Phase-groundV-A-HzV ac+dcA ac+dcHz 
V peakV peak maxV peak minV pk-to-pkCrest factor
A peakA peak maxA peak minA pk-to-pkCrest factor
Voltage unbalanceUnbalanceV ac+dcV ac+dcV ac+dcUnbalance
PeakV pk-to-pkV pk-to-pkV pk-to-pk 
Current unbalanceUnbalanceA ac+dcA ac+dcA ac+dcUnbalance
PeakA pk-to-pkA pk-to-pkA pk-to-pk 
Motor drive DC bus
DC V dcV pk-to-pkV peak max 
Ripple V acV pk-to-pkHz 
Motor drive output
Voltage and current (filtered)V-A-HzV PWMA ac+dcHzV/Hz
V peakV peak maxV peak minV pk-to-pkCrest factor
A peakA peak maxA peak minA pk-to-pkCrest factor
Voltage unbalanceUnbalanceV PWMV PWMV PWMUnbalance
PeakV pk-to-pkV pk-to-pkV pk-to-pk 
Current unbalanceUnbalanceA ac+dcA ac+dcA ac+dcUnbalance
PeakA pk-to-pkA pk-to-pkA pk-to-pk 
Voltage modulation
Phase-phaseZoom 1V PWMV pk-to-pkHzV/Hz
Zoom 2V peak maxV peak minDelta V 
Zoom 3 peakV peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Phase-groundZoom 1V PWMV pk-to-pkV peak maxV peak min
Zoom 2V Peak maxV peak minDelta VHz
Zoom 3 peakV Peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Phase-DC +Zoom 1V PWMV pk-to-pkV Peak maxV peak min
Zoom 2V peak maxV peak minDelta VHz
Zoom 3 peakV peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Phase-DC -Zoom 1V PWMV pk-to-pkV peak maxV peak min
Zoom 2V peak maxV peak minDelta VHz
Zoom 3 peakV peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Motor input
Voltage and current (filtered)V-A-HzV PWMA ac+dcHzV/Hz
V peakV peak maxV peak minV pk-to-pkCrest factor
A peakA peak maxA peak minA pk-to-pkCrest factor
Voltage unbalanceUnbalanceV PWMV PWMV PWMUnbalance
PeakV pk-to-pkV pk-to-pkV pk-to-pk 
Current unbalanceUnbalanceA ac+dcA ac+dcA ac+dcUnbalance
PeakA pk-to-pkA pk-to-pkA pk-to-pk 
Voltage modulation
Phase-phaseZoom 1V PWMV pk-to-pkHzV/Hz
Zoom 2V peak maxV peak minDelta V 
Zoom 3 peakV peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Phase-groundZoom 1V PWMV pk-to-pkV peak maxV peak min
Zoom 2V peak maxV peak minDelta VHz
Zoom 3 peakV peak maxDelta V/sRisetime peakOvershoot
Zoom 3 levelDelta VDelta V/sRisetime levelOvershoot
Motor shaft
Shaft voltageEvents offV pk-to-pk   
Events onDelta VRise/fall timeDelta V/sEvents/s
Motor drive input, output and motor input
HarmonicsVoltageV acV fundamentalHz fundamental% THD
CurrentA acA fundamentalHz fundamental% THD/TDD
 
Measurement FunctionSpecification
DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe (voltage to ground)1mV / 10mV
Full scale reading999 counts
Accuracy at 4 s to 10 us/div± (1.5 % + 6 counts)
True-rms voltage (V ac or V ac + dc) (with DC coupling selected)
Maximum voltage with 10:1 or 100:1 probe (voltage to ground)1000 V
Maximum resolution with 10:1 or 100:1 probe1 mv / 10 mV
Full scale reading999 counts
DC to 60 Hz± (1.5 % + 10 counts)
60 Hz to 20 kHz± (2.5 % + 15 counts)
20 kHz to 1 MHz± (5 % + 20 counts)
1 MHz to 25 MHz± (10 % + 20 counts)
PWM voltage (V pwm)
PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
AccuracyAs Vac+dc for sinewave signals
Peak voltage (V peak)
ModesMax peak, min peak, or pk-to-pk
Maximum voltage with 10:1 or 100:1 probe (voltage to ground)1000 V
Maximum resolution with 10:1 or 100:1 probe10 mV
Accuracy
Max peak, min peak± 0.2 division
Pk-to-pk± 0.4 division
Full scale reading800 counts
Current (AMP) with current clamp
RangesSame as V ac, Vac+dc or V peak
Scale Factors0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
AccuracySame as Vac, Vac+dc or V peak (add current clamp accuracy)
Frequency (Hz)
Range1.000 Hz to 500 MHz
Full scale reading9999 counts
Accuracy± (0.5 % + 2 counts)
Voltage/Herz ratio (V/Hz)
PurposeTo show the measured V PWM value (see V PWM) divided by the fundamental frequency on vari- able ac motor speed drives
Accuracy% Vrms + % Hz
Voltage unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
AccuracyIndicative percentage based on Vac+dc values
Voltage unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 PWM voltages
AccuracyIndicative percentage based on V PWM values
Current unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on Aac+dc values
Current unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on A ac values
Rise and fall time
ReadingsVoltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot
AccuracyAs oscilloscope accuracy
Harmonics and spectrum
HarmonicsDC to 51st
Spectrum ranges1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation)
Shaft voltage
Events / secondIndicative percentage based on rise and fall time (Impulse discharges) measurements
Report data capture
Number of screensTypical 50 screens can be saved in reports (depends on compression ratio)
Transfer to PCUsing 32 GB or smaller 2 GB USB stick or mini-USB to USB cable or WiFi link and FlukeView™ 2 for ScopeMeter®
Probe settings
Voltage Probe1:1, 10:1, 100:1, 1000:1, 20:1, 200:1
Current Clamp0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Shaft Voltage Probe1:1, 10:1, 100:1
Safety
GeneralIEC 61010-1: Pollution Degree 2
MeasurementMeasurement IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V
Maximum voltage between any Terminal and Earth Ground1000 V
Max. input voltagesVia VPS410-II or VPS421 1000 V CAT III / 600 V CAT IV
BNC InputA, B, C, D directly 300 V CAT IV
Max. Floating Voltage, test tool or test tool with VPS410-II / VPS421 voltage probeFrom any terminal to earth ground 1000 V CAT III / 600 V CAT IV Between any terminal 1000 V CAT III / 600 V CAT IV
Working voltage between probe tip and probe reference leadVPS410-II: 1000 V
VPS421: 2000 V

Models: Fluke MDA-550 Series III Motor Drive Analyzer

Fluke MDA-550 Series III Motor Drive Analyzer
Part#: 5282560
UPC#: 1 95112 02195 8
  • 1x BP 291 li-ion battery pack
  • 1x BC190 charger/power adapter
  • 3x VPS421 100:1 high voltage probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage probe
  • 3x i400s ac current clamp
  • 1x SVS-500 shaft voltage set (3x brush
  • Probe holder
  • Two-piece extension rod and magnetic base
  • Large size, protective carrying case with rollers (C437-II)
  • FlukeView-2 PC software (full version)
  • WiFi dongle
FLUKE-MDA-550/FPC

Fluke MDA-550 Series III Motor Drive Analyzer Bundled with Premium Care 1-Year Standard Plan

Part#: 5335299
UPC#: 7 54082 15530 0

Includes:

  • Premium Care 1-Year Standard Plan
  • MDA-550
  • 1x BP 291 li-ion battery pack
  • 1x BC190 charger/power adapter
  • 3x VPS421 100:1 high voltage probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage probe
  • 3x i400s ac current clamp
  • 1x SVS-500 shaft voltage set (3x brush, probe holder, two-piece extension rod and magnetic base)
  • Large size, protective carrying case with rollers (C437-II)
  • FlukeView-2 PC software (full version)
  • WiFi dongle
FPC1S-MDA-500-1

Premium Care 1-Year Standard Plan for Fluke MDA-550 Series III Motor Drive Analyzer

Part#: 5326099
UPC#: 1 95112 03832 1

Includes:

Premium Care 1-Year Standard Plan

FPC3S-MDA-500-1

Premium Care 3-Year Standard Plan for Fluke MDA-550 Series III Motor Drive Analyzer

Part#: 5326105
UPC#: 1 95112 03833 8

Includes:

Premium Care 3-Year Standard Plan

FPC1G-MDA-500-1

Premium Care 1-Year Gold Plan for Fluke MDA-550 Series III Motor Drive Analyzer

Part#: 5326789
UPC#: 1 95112 03841 3

Includes:

Premium Care 1-Year Gold Plan

FPC3G-MDA-500-1

Premium Care 3-Year Gold Plan for Fluke MDA-550 Series III Motor Drive Analyzer

Part#: 5326792
UPC#: 1 95112 03842 0

Includes:

Premium Care 3-Year Gold Plan

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 21.87ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.55ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat