5080A High Compliance Multi-Product Calibrator

Model#:5080A
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 309.29ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 5080A High Compliance Multi-Product Calibrator
  • 5080A High Compliance Multi-Product Calibrator
  • 5080A High Compliance Multi-Product Calibrator
  • 5080A High Compliance Multi-Product Calibrator

Key features

  • Calibration solutions for both analog and digital workloads with high compliance and protection circuitry.
  • Calibrate analog meters, 3.5 and 4.5 digits DMMs, panel meters, watt meters, clamp meters, oscilloscopes up to 200 MHz, and more.
  • Equipped with versatile software applications for paperless results recording.
  • Built-in protection circuitry to safeguard against damaging input voltages.

Product overview: 5080A High Compliance Multi-Product Calibrator

Accurate, reliable analog meter calibration


The 5080A Multi-Product Calibrator calibrates your analog workload accurately and reliably, thanks to its high voltage and current compliance. With maximum burden up to 800 mA for ac/dc voltage, and voltage up to 50 V for ac/dc current, 5080A calibrators can drive a wide range of analog meters.

Options and accessories expand workload coverage

Options and accessories enable you to use the 5080A Multi-Product Calibrator to calibrate an even broader workload, including:

  • Clamp meters. The 9100-200 10/50 turn coil and 5500A/COIL 50-turn current coil enables the 5080A to calibrate most popular clamp meters at currents up to 1000 A rms amps.
  • Oscilloscopes. Oscilloscope calibration to 200 MHz quickly, easily, and cost effectively. Verify dynamic response, bandwidth, timing, multiple triggering functions, and input resistance.
  • Megohm meters. This option sources high ohms, high voltage resistors up to 18 G ohms. It also measures high voltage outputs.

Protective circuits prevent damage

Mains voltage inadvertently applied to a calibrator’s output terminals can cause extensive damage, requiring costly repairs. Electrical protection for calibrator outputs is vital for daily operation. The 5080A calibrator’s innovative protection circuitry prevents it from being damaged by reversed input voltage, so you can use it with confidence day after day.

Highest voltage and current compliance

The 5080A has the highest voltage and current compliance of any calibrator in the Fluke Calibration multi-product and multifunction calibrator families, making it an ideal solution for calibrating analog meters and other instruments requiring higher drive capability for proper operation.

Maximum burden or compliance voltage
Functions
ModelDC voltageAC voltageDC currentAC current*
5080A600 mA800 mA50 V44 V
910020 mA20 mA4 V4 V
5500A10 mA10 mA4.5 V3 V
5520A10 mA10 mA7 V5 V
5700A50 mA50 mA10 V7 V
5720A50 mA50 mA10 V7 V

* With AC LCOMP on

Automate the 5080A Multi-Product Calibrator to increase efficiency and throughput

For the full spectrum of calibration automation and asset management, choose MET/CAL software

The solutions you need, from the leader in calibration

Fluke Calibration is a premium brand, well known around the world for its accurate, dependable, high quality products. Long known as a leader in dc and low frequency ac calibration, Fluke Calibration is also recognized for its offerings in temperature, pressure, power, process, and rf calibration. Fluke Calibration provides the calibrators, standards, software, service, support and training you need for a complete solution in your cal lab.

Specifications: 5080A High Compliance Multi-Product Calibrator

Technical Specifications
Voltage DCRange: 0 to ±1020V
Best 1 Year Specification: ±0.025% of setting
Current DCRange: 0 to ±20.5A
Best 1 Year Specification: ±0.025% of setting
ResistanceRange: 0 to 190 MO, 19 values in x1 and x1.9
Best 1 Year Specification: ±0.025% of setting
Voltage ACRange: 1 mV to 1020V
45Hz to 1 kHz, Sine
Best 1 Year Specification: ±0.25% of setting
Current ACRange:29 mA to 20.5A
45 Hz to 1 kHz, Sine
Best 1 Year Specification: ±0.25% of setting
DC PowerRange:10.9 mW to 20.5 kW
Best 1 Year Specification: ±0.125% of setting
AC PowerRange: 10.9 mW to 20.5 kW
45-65 Hz, PF=1
Best 1 Year Specification: ±0.36% of setting
PhaseRange: 0 to ± 179.99°
45 Hz to 1 kHz
Best 1 Year Specification: ±0.25° of setting
FrequencyRange: 45 Hz to 1 kHz
Best 1 Year Specification: ±50 ppm of setting
General Specifications
Warm up Time Twice the time since last warmed up, to a maximum of 30 minutes
Settling TimeLess than 5 seconds for all functions and ranges except as noted
Standard InterfacesRS-232 and Ethernet
Temperature PerformanceOperating: 0°C to 50°C
Calibration (tcal):15°C to 35°C
Storage:-20°C to +70°C
Temperature CoefficientTemperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
Relative HumidityOperating: <80% to 30°C, <70% to 40°C, <40% to 50°C
Storage:<925%, non-condensing
AltitudeOperating: 2,000m (6,500 ft) maximum
Non-operating: 12,200m (40,000 ft) maximum
SafetyMeets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
Analog Low Isolation20V
EMCMeets EN613261:2006.
Line PowerLine Voltage (selectable): 100V, 120V, 220V, 240V
Line Frequency: 47 to 63 Hz
Line Voltage Variation: + 25% about line voltage setting
Power Consumption600 VA
Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
DimensionsHeight:19.3 cm (7.6 in)
Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
Depth:53.8 cm (21.2 in)
Weight (without options)22 kg (48 lbs.)
Absolute Uncertainty Definition
The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
Specification Confidence Interval99%

Models: 5080A High Compliance Multi-Product Calibrator

5080A
Multi-Product Calibrator

5080A/MEG
Multi-Product calibrator with Megohm Meter Calibration Option

5080A/SC
Multi-Product Calibrator with Oscilloscope Calibration Option

5080A/SC/MEG
Multi-Product Calibrator with Megohm Meter and Oscilloscope Calibration Option

5080A -> 5080A/MEG

Upgrade 5080A to 5080A/MEG - Installable only at Fluke service centers for extra installation and calibration cost.


5080A -> 5080A/SC/MEG
Upgrade 5080A to 5080A/SC/MEG - Installable only at Fluke service centers for extra installation and calibration cost.

9100-200
10/50 Turn Coils
Part#: 1583963
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 68.52ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.97ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat