Vibration monitoring and analysis best practices

Monitoring machines for vibration can save you time and money. A machine going offline can impact quality and production. Monitoring machines for vibration issues identifies trends and helps reduce the potential for the machine going offline. Catch vibration issues early with vibration data that identifies imbalance, looseness, misalignment, and bearing failures. Learn how to troubleshoot vibration issues efficiently and effectively.

Fluke has vibration testing equipment for when troubleshooting or routine tests are needed and vibration monitoring to help you stay up and running.

Speak to a Fluke specialist

Vibration monitoring and analysis best practices

Videos

On-demand webinars

Predictive maintenance

  • Watch now

All vibration articles

Article

Most common causes of machine vibration

Vibration can result from a number of conditions, acting alone or in combination. Keep in mind that vibration problems might be caused by auxiliary equipment, not just the primary equipment.

Article

Demystifying Vibration Monitoring Part 3: Identifying and Interpreting Overall Vibration and Fault Patterns

Overall vibration analysis, in contrast to spectrum analysis, is much simpler. The time domain data is used to calculate one single overall vibration value, which represents the average energy of the vibration sample.

Article

Everything You Need to Know About Vibration Meters

Article

Demystifying Vibration Monitoring Part 4: Diagnosing Imbalance, Misalignment, Looseness, and Bearing Wear

Article

How Azima Integrates with eMaint: AI Maintenance Recommendations that Can Save You Millions 

Article

Casa del Rulimán and Azima Help Ecuador's Industrial Giants Pivot to Smarter Maintenance Strategies

Article

Diagnosing Ski Slopes and Accelerometer Overload in Vibration Data

Article

What is Pump Condition Monitoring?

Article

Fluke Reliability Introduces the New VibXpert 3 Balancer

Article

Correcting Rotational Unbalance with the VibXpert 3

Article

Unlocking efficiency and reliability: Condition Monitoring from Fluke Reliability is revolutionizing the automotive industry

Article

A Guide to Vibration Sensors for Motors

Article

Reliability in Action: Azima Powers Efficiency for a Decade at the World’s Largest Methanol Producer 

Article

The Importance of Standard Test Conditions – Test Speed and Test Load

Article

Why Taking Data Once a Month Is Not Sufficient: 3 Case Studies Reveal the Risks

Article

Correcting rotational asymmetry with the VibXpert 3

Article

Fluke Reliability Introduces New VibXpert 3 Balancer

Article

Piezo Sensor: Definition, Benefits, How They Work

Article

What Is Vibration Analysis? A Complete Guide

Article

The $200,000 Mistake Wind Turbine Operators Keep Making

Article

Keeping Uptime Alive After Experts Retire: The Role of AI in Data Centers

Article

What Vibration Data Tells You About Equipment Health in Data Centers (That Inspections Can’t)

Article

Phase in Vibration Analysis: Theory, Applications, and Examples

Article

Behind the Barrels: A Roadshow to Remember at Green River Distilling Co.

Article

How Automation and Standardization Are Transforming Training and Retention in the Workforce

Article

Mobility: The Missing Piece in Vibration Analysis (Part 1): Why More Vibration Isn’t Always Worse

Article

Mobility: The Missing Piece in Vibration Analysis (Part 2): From Theory to Force Spectra

Article

What Is The “Crest Factor” And Why Is It Used?

Article

How Predictive Maintenance Programs Fail When Teams Misuse Technology

Article

Turning Big Data into Big Wins with Automated Vibration Analysis

Article

Why PdM Programs Fail: Personnel Issues 

Article

How to Check Pump Coupling Alignment

Article

Three Axes, One Clear Picture: Unlocking Machine Faults with Triaxial Data

Article

How Azima Helps You Achieve KPI Targets with Better Data Insights

Article

Stop Playing Maintenance Whack-a-Mole: How to Focus Maintenance Where It Counts The Most

Article

Measuring Vibration for Predictive Maintenance

Article

Why Remote Monitoring Still Defines Predictive Maintenance

Article

Cooling Failures: The Hidden Threat to Data Center Uptime

Article

When Linear Lies: What You’re Not Seeing in Your Vibration Data

Article

Data Center Predictive Maintenance: How To Separate Noise From Risk

Article

Linear vs. Non-Linear Systems Explained | Machine Faults in Action | Part 3

Article

How Demodulation Helps You Detect Bearing Faults Early

Article

 Triaxial vs. Single-Axis Sensors: Are they equivalent?

Article

Unlocking the Value of Big Data in Industrial AI: Azima DLI's Competitive Edge

Article

Your Guide to Xcelerate 2025: Agenda & Key Details

Article

The Azima Difference: Precise Condition Monitoring With No Added Labor Costs

Article

Linear vs. Non-Linear Systems Explained | Machinery Vibration | Part 1

Article

Quick Wins, Even Quicker ROI With Azima DLI

Article

The Azima Advantage: Using Industrial AI to Extend Asset Lifespan

Article

Linear vs. Non-Linear Systems Explained | Identifying Machine Health | Part 2

Article

Fluke Survey Reveals 97% of Manufacturers Will Leverage AI to Tackle High-Skilled Labor Shortage

Article

Why Vibration Monitoring Matters in Data Centers

Article

5 Key Types of Vibration Measurement Tools

Article

No More False Alarms: How Advanced Vibration Sensors Provide Accurate Monitoring for Critical Assets  

Article

Correcting rotation imbalance with VibXpert 3

Article

Fluke Reliability Introduces New VibXpert 3 Balancer Test Tool

Article

When Machines Teach Machines: AI and ML in Remote Condition Monitoring

Article

Maintaining Reliable Assets With a Limited Workforce

Article

Correcting imbalances with the VibXpert 3

Article

Leading Cement Manufacturer Optimizes Gearbox Monitoring with Fluke’s VibGuard Solution

Article

Smarter Bearing Monitoring: How to Catch Failures Before They Cost You

Article

Why Should I Use Vibration Monitoring?

Article

Correcting rotational imbalances with VibXpert 3

Article

Maintenance Leaders, Get Your Seat at the Table: Thought Leadership Day at Xcelerate 2025

Article

Azima AI — How Does It Work?

Article

How Smart Diagnostics Are Changing the Rules of Machine Monitoring

Article

Top 9 industrial applications for remote vibration monitoring sensors

Vibration screening helps maintenance and reliability teams avoid rotating machine failure.

Article

Top 3 diagnostic challenges solved with condition monitoring

Limited resources can make monitoring all vital plant equipment difficult, if not impossible. That’s where a condition monitoring system with wireless sensors monitoring comes in.

Article

From screwdrivers to testers: Vibration analysis comes of age

Most machines have rotating parts, and rotating parts vibrate. Measuring how and how much those parts vibrate can tell you a lot about the health of a machine.

Article

Understanding Vibration Measurement: A Detailed Guide

Article

Preventing machine failure by detecting the first signs of trouble

Preventing machine failure by detecting the first signs of trouble

Article

Software reveals power of data to more maintenance managers

CNX 3000 wireless test tool field trial by electrical contractor AECI in industrial facilities: trouble call applications

Article

Understanding Vibration Monitoring and Analysis

Vibration testing for condition-based maintenance, to reduce costs and production losses. Mechanics of testing, analyzing roller bearing faults.

Article

Taking a Wireless Approach Gets to the Root of the Problem Faster

Follow the experiences with wireless test tools of electrician Chipper Stohl of AECI, as he works primarily in emergency troubleshooting and repair, with some installation and maintenance.

Article

Techs are tuned in to benefits of wireless testing

Wireless testing survey results with comments and insights from Fluke tool users

Article

Inspect moving machinery by putting the 'freeze' on

New stroboscope helps frontline mechanical troubleshooting teams precisely measure machine rotation and oscillation without shutting down the equipment.

Article

Which assets should be screened for vibration?

Figuring out which assets should be screened for vibration can be difficult. Installing vibration monitoring sensors on key assets can increase uptime and reduce costs.

Article

Improve uptime with new vibration analysis tools

Article

3 ways to improve motor health with vibration testing

One would be hard-pressed to find a facility manager who doesn’t want maintenance operations to run as smoothly as possible. Detecting signs of motor components failure becomes easier when combined with a preventive vibration program.

Article

Guide to machine faults and how to get to root cause

90 percent of machine faults fall into four main categories: misalignment, imbalance, looseness, or bearing wear. Using root cause analysis can help you identify where a problem began and what caused it.

Article

Demystifying Failure Modes: Matching Machines and Failure Modes

The Fluke 810 Vibration Tester locates and identifies the four most common types of mechanical faults and allows for quick and easy assessments of overall machine health.

Article

5 ways condition monitoring can improve your maintenance program

Wireless sensors paired with condition monitoring software can improve reliability programs, decrease costs and increase uptime.

Article

Understanding the practicality of graded asset health

Identifying the severity of a problem by looking at data can be difficult. Color-coded, varying severity alarms enable maintenance managers to make better data-driven decisions.

Article

Top 5 benefits of vibration monitoring

Screening is an economical way to monitor assets by automating data collection. Learn more about the benefits of implementing vibration monitoring in your plant.

Article

What is an Industrial Vibration Sensor?

Maintenance professionals may not realize how using vibration sensors can improve facility efficiency. Learn about which industrial sectors can benefit from vibration sensors.

Article

When and how to use and set up vibration monitoring on assets

Breaking down the process and rationale for successfully adding these sensors for condition monitoring

Article

No expertise required: Setting up aerospace vibration sensor

To use vibration sensors, many maintenance and reliability personnel believe they have to be a vibration expert. For some sensors, this may be true. However, for the 3561 FC Vibration Sensors paired with Fluke Connect™ Condition Monitoring (FCCM) software, expertise is not required.

Article

Glossary of Vibration Terms

Glossary of Vibration Terms