Electrical Calibration Workload Matrix

Use this guide to help choose the right electrical calibrator for your application.
This guide summarizes the functions, accuracies and targeted workload of every Fluke Calibration electrical calibrator; including electrical multi-product calibrators, multifunction calibrators, oscilloscope calibrators, electrical tester calibrators, power and energy calibrators and standards, and precision process calibrators. This selection guide is intended to help you decide which calibrator best fits which class of test equipment and the associated performance levels required.

For additional help selecting an electrical calibrator, 
 
 Multi-Product CalibratorsMultifunction Calibrators
Workload5080A5540A5550A5560A5730A
Analog/panel meters
High burden metersYES    
Low burden meters     
DMMs
Basic DC V accuracy at 99 %100 ppm31 ppm11 ppm8 ppm4.5 ppm
3.5 digits
(typ. ± 0.3 % DC V)
     
4.5 digits
(typ. ± 0.025 % DC V)
     
5.5 digits
(typ. ± 0.015 % DC V)
     
6.5 digits
(typ. ± 0.0030 % DC V)
     
7.5 digits
(typ. ± 12 ppm DC V)
     
Temperature/pressure
RTD simulate     
Thermocouple simulate     
Thermocouple measure     
Oscilloscopes1 channel1 to 5 channels
200 MHz to 600 MHz200 MHz opt600 MHz opt600 MHz opt600 MHz opt 
1.1 GHz  1.1 GHz opt1.1 GHz opt 
2.1 GHz   2.1 GHz opt 
Safety testers
Megohm metersMEG opt    
ContinuityMEG opt    
Power/energy
Wattmeters     
Phase angle meters     
Power analyzers     
Power recorders     
Watt-hour/energy meters     
Other
Clamp meters     
LCR meters RC onlyLRCLRC 
Process calibrators     
Data acquisition     
Non sine waveforms     
RF millivolt meters    30 and 50 MHz WB opt
# of calibrator functions81111115
 
 Oscilloscope CalibratorsElectrical Tester CalibratorPower and Energy CalibratorsTemperature and Pressure Calibrator
Workload9500B5322A6100B6105A7526A
Analog/panel meters
Low burden meters V DC and V AC  V DC, I DC and R
DMMs
Basic DC V accuracy at 99 %n/a1000 ppm112 ppm42 ppm40 ppm
3.5 digits
(typ. ± 0.3 % DC V)
 V DC and V AC  V DC and V AC
Temperature/pressure
RTD simulate     
RTD measure     
Thermocouple simulate     
Thermocouple measure     
Pressure modules     
Oscilloscopes1 to 5 channels
200 MHz to 600 MHz600 MHz std    
1.1 GHz9510 Head opt    
2.1 GHz     
3.2 GHz9530 Head opt    
6.4 GHz9560 Head opt    
25 ps fast edge (14 GHz)9550 Head opt    
Safety testers
Hipot     
Megohm meters     
Installation     
PATs     
Continuity     
Loop impedance     
Leakage current     
Ground bond     
RCD/GFCI     
Medical safety     
Power/energy
Wattmeters     
Harmonic analyzers     
Flicker meters     
Phase angle meters     
Power analyzers     
Power recorders     
Secondary energy standards     
Watt-hour/energy meters     
Other
# of calibrator functions11+9889


Specifications subject to change without notice.