Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
Tính năng chính
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
The Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
Tổng quan sản phẩm: Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit is part of the Fluke Connect® team of wireless test tools
Connect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.
You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harm’s way.
Thông số kỹ thuật: Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).
AC Voltage | |||
Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | ||
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | |||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
mV | Range / resolution | 600.0 mV / 0.1 mV | |
Accuracy | 0.09% + 2 | ||
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy | 0.09% + 2 0.15% + 2 | ||
))) | Range / resolution | 600 Ω / 1 Ω | |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | ||
Diode test | Range / resolution | 2.000 V / 0.001 V | |
Accuracy | 1% + 2 | ||
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF | |
Accuracy | 1.2% + 2 10% typical | ||
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||
AC and DC Current | |||
mA AC (45 Hz to 1 kHz) | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | |
Accuracy | 1.5% + 3 | ||
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | |
Accuracy | 0.5% + 3 | ||
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | |||
Frequency | |||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | ||
Accuracy1 | 0.1% + 1 | ||
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||
Input Characteristics | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Open Circuit Test Voltage | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 VDC < 0.9 VDC | ||
Typical short circuit current | < 350 mA | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 VDC | ||
Typical short circuit current | < 1.1 mA | ||
mA Function | |||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording Accuracy | |||
DC functions | ±12 counts for changes > 350 mS in duration. | ||
AC functions | ±40 counts for changes > 900 mS in duration. | ||
General Specifications | |||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||
Display (LCD) | Update rate | 4/sec | |
Volts, amps, ohms | 6000 counts | ||
Frequency | 10,000 counts | ||
Capacitance | 1,000 counts | ||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||
Battery life | 250 hours minimum | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | Open air, unobstructed | Up to 20 m | |
Obstructed, sheetrock wall | Up to 6.5 m | ||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5 m | ||
Temperature | Operating | -10°C to 50°C | |
Storage | -40°C to 60°C | ||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||
Altitude | Operating | 2,000 m | |
Storage | 12,000 m | ||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | ||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 | ||
Certifications | CSA, FCC, CE | ||
Ingress Protection (IP) rating | IP54 | ||
Pollution Degree | 2 | ||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
Weight | 340 g (12 oz) | ||
Warranty | Three years | ||
Not compatible with Fluke CNX test tools |
Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ±5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |
LCD w/ backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Model: Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
Includes:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke a3001 FC Wireless iFlex AC Current Module
- TL175 Test Leads
- AC175 Alligator Clips
- iFlex i2500-10 Flexible Current Probe
Sách hướng dẫn + tài nguyên: Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
- 3000 FC | Sổ tay hướng dẫn sử dụng
- 3000 FC | Hướng dẫn tham khảo nhanh
- 3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- 3000 FC | Sổ tay hướng dẫn hiệu chuẩn bổ sung
- 3000 FC | Bảng thông tin an toàn
- a3000 FC | Bảng thông tin an toàn
- a3000 FC | Hướng dẫn tham khảo nhanh
- a3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3001 FC | Hướng dẫn tham khảo nhanh
- a3001 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3001 FC | Bảng thông tin an toàn
- a3001 FC | Bảng thông tin an toàn bổ sung
- a3002 FC | Hướng dẫn tham khảo nhanh
- a3002 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3002 FC | Bảng thông tin an toàn
- Fluke Connect | Hướng dẫn tham khảo nhanh
- Fluke Connect Wi-Fi to Thermal Imager | Hướng dẫn tham khảo nhanh
- ir3000 FC | Hướng dẫn tham khảo nhanh
- pc 3000 FC | Bản hướng dẫn
- t3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- t3000 FC | Hướng dẫn tham khảo nhanh
- t3000 FC | Bảng thông tin an toàn
- t3000 FC | Bảng thông tin an toàn bổ sung
- v3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- v3000 FC v3001 FC | Hướng dẫn tham khảo nhanh
- v3000 FC v3001 FC | Bảng thông tin an toàn
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Báo cáo về bộ nhớ khả biến
- v3001 FC | Sổ tay hướng dẫn hiệu chuẩn
- Performing predictive maintenance with Fluke Connect™
- How to email a measurement using the Fluke Connect app
- Saving measurements with AutoRecord™ measurements
- Connecting multiple tools at the same time with Fluke Connect®
- Connecting a thermal imager to your iPhone
- Measurement history in one place using EquipmentLog™ history
- Identifying intermittent conditions with TrendIt™ graphs
- Measuring from a safe distance using the Fluke Connect™ app
- How to create an equipment baseline with EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Viewing and graphing three phase measurements
- Connecting the T3000 FC with the Fluke Connect™ app
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history