Dear Fluke customer:
In cooperation with the U.S. Consumer Product Safety Commission, Fluke is voluntarily recalling its Fluke 1AC-I VoltAlert™ voltage tester, a product that was first released for sale on September 29, 2009. The affected model number is listed in the table below. If you own a Fluke 1AC-I (1AC-A1-I), please stop using it and send it back to Fluke for a replacement unit. If you are not the primary user of the 1AC-I please pass this notice along to the appropriate people within your organization.
Product marking: | Description |
---|---|
1AC-AI | FLUKE-1AC-I VoltAlert™ Voltage Tester |
This recall does not include VoltAlert models 1AC-II, 1LAC-II and LVD2, none of which includes the battery check button or the Fluke logo on its clip, as shown below on the recalled units pictured. |
Description of the problem: |
---|
The testers can fail to give an indication of live voltage, resulting in the operator falsely believing the electrical power is off, posing a risk of serious injury or death from electrical shock or thermal burns. |
Actions: |
---|
|
We are undertaking this voluntary recall because we place tremendous importance on our customer's safety and the reputation of our products. Please accept our apologies for any inconvenience caused by this action.