Fluke 9132/9133 Portable Infrared Calibrator

  • Fluke 9132/9133 Portable Infrared Calibrator 1
  • Fluke 9132/9133 Portable Infrared Calibrator

Belangrijkste kenmerken

  • Accurate, reliable performance from –15 °C to 500 °C
  • Small, compact design in a blackbody calibrator
  • These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm).
  • Intuitive, easy-to-read display that indicates when temperature is stable.

Productoverzicht: Fluke 9132/9133 Portable Infrared Calibrator

Precision when you need it for infrared temperature calibration


Fluke 9132: blackbody calibration up to 500 °C
For IR calibrations above normal ambient, the Fluke 9132 blackbody calibration source provides a stable measurement surface up to 500 °C (932 °F). Short heating and cooling times mean you won’t have to wait long to get your work done. Radiometric calibration gives you confidence in your measurements to 500 °C.

Fluke 9133: blackbody calibration from -30 °C to 150 °C
If you’re calibrating IR thermometers at cold temperatures, you’ll love our new Fluke 9133 blackbody calibration source. With solid-state cooling technology, this new IR calibrator reaches –30°C (22°F) in normal ambient conditions. With a conveniently located dry gas fitting on the front bezel, ice build up on the target can be avoided. At the upper end of its range, the Fluke 9133 provides stable temperatures to 160°C (320°F).

With heating and cooling times of about 15 minutes from ambient to either extreme, the Fluke 9133 gets you to temperature quickly and performs when it gets there.



 

Specificaties: Fluke 9132/9133 Portable Infrared Calibrator

Specifications91329133
Temperature range50°C to 500°C
(122°F to 932°F)
–30°C to 150°C at 23°C ambient
(–22°F to 302°F at 73°F ambient)
Accuracy±0.5°C at 100°C
(±0.9°F at 212°F)
±0.8°C at 500°C
(±1.4°F at 932°F)
±0.4°C (±0.72°F)
Stability±0.1°C at 100°C
(±0.18°F at 212°F)
±0.3°C at 500°C
(±0.54°F at 932°F)
±0.1°C (±0.18°F)
Target size57 mm (2.25 in)57 mm (2.25 in)
Target emissivity0.95 (±0.02 from 8 to 14 mm)0.95 (±0.02 from 8 to 14 mm)
Resolution0.1°0.1°
Heating time30 minutes (50°C to 500°C)15 minutes (25°C to 150°C)
Cooling time30 minutes (500°C to 100°C)15 minutes (25°C to –20°C)
Computer interfaceRS-232 I/O included
Power115 V AC (±10%), 3 A or
230 V AC (±10%), 1.5 A,
switchable, 50/60 Hz, 340 W
115 V AC (±10%), 1.5 A, or
230 V AC (±10%), 1.0 A,
switchable, 50/60 Hz, 200 W
Size (H x W x D)102 x 152 x 178 mm
(4 x 6 x 7 in )
152 x 286 x 267 mm
(6 x 11.25 x 10.5 in)
Weight1.8 kg (4 lb)4.6 kg (10 lb)
NIST-traceable contact calibrationData at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°CData at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C

Modellen: Fluke 9132/9133 Portable Infrared Calibrator

9132

Portable IR Calibrator, 500 °C


Kopen
9133

Portable IR Calibrator, –30 °C


Kopen