RPM4 BA100K Reference Pressure Barometer
主な機能
- 不確かさ: シングル・チャネルで ± 0.01%、デュアル・チャネルで ± 0.008%。
- 並列測定モードのシングルまたはデュアル・チャネルで信頼性を向上。
- インターフェイス: RS232 および IEEE-488 を含む。
製品概要: RPM4 BA100K Reference Pressure Barometer
The RPM4 BA100K is a full function laboratory quality barometer intended to measure atmospheric pressure with the very highest performance. Its outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.
仕様: RPM4 BA100K Reference Pressure Barometer
RPM4 BA100K (Single Channel) | RPM4 BA100K/BA100K (Dual Channel) | |
---|---|---|
Range | 70 kPa to 110 kPa (10 psia to 16 psia) | |
Power requirements | 85 V ac to 264 V ac, 50/60 Hz; 12 V dc, 1.2 A (battery) | |
Weight | 5 kg (11 lb) | |
Dimensions (H x W x D) | 10 cm x 22.7 cm x 24 cm (3.9 in. x 8.9 in. x 9.5 in.) | |
Test port connections | 1/8 in NPT F | |
Communications ports | RS232 (COM1, COM2), IEEE-488.2 Resolution To 1 ppm, user adjustable To 1 ppm, user | |
Resolution | To 1 ppm, user adjustable | |
Operating temperature | 15 °C to 35 °C (59 °F to 95 °F) | |
Warm up time | 30 minute temperature stabilization recommended from cold power up | |
Vibration | Meets MIL-T-28800D | |
Predicted Stability1 | ± 0.005 % of reading | ± 0.0032 % of reading |
Precision2 | ± 0.008 % of reading | ± 0.006 % of reading |
Measurement Uncertainty3 | ± 0.01 % of reading | ± 0.008 % of reading |
1Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is performed by the operator by comparison with a barometric reference in absol mode. Absolute mode predicted one year stability without AutoZ is: Single Channel ± (5 Pa + 0.005 % of reading), D Channel ± (4 Pa + 0.0032 % of reading). 2Combined linearity, hysteresis, repeatability. 3Maximum deviation of the Q-RPT indication from the true value of applied spressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.” |
モデル: RPM4 BA100K Reference Pressure Barometer
RPM4 mhhhac/mlllac
基準圧力モニター
ここで、
mhhhac は Hi Q-RPT の仕様です。
c は Q-RT のクラスです(s = 標準、p = プレミアム)
mlllac は Lo Q-RPT の仕様とクラスです。Lo Q-RPT がない場合は、空白のままにします。
使用可能な Q-RPT については、「特徴」の Q-RPT およびレンジの表を参照してください。
RPM4 04
-1 米国単位版 -2 SI 単位版
RPM4 05
CE マーク
RPM4 06
特別校正
RPM4 07
特殊試験液、Hi Q-RPT(液体を指定)
RPM4 08
特殊試験液、低 Q-RPT(液体を指定)
RPM4 09
-1 特殊構成、エアー・データ(A160K/A160K、A350K/A160Kのみ)
RPM4-LP
Low Pressure Monitor, -15 to 15 kPa (-60 to 60 inH2O)
3990-803
手動圧力制御パック、最大 3000 psi(207 bar)