molbox1+ or molbox1+S v6.01 Embedded Software

molbox1+ or molbox1+S v6.01 Embedded Software (.bin)

TITLEVERUSE WITH
molbox1+/molbox1+S™6.01
2016.12.16
molbox1+/molbox1+S
TITLEVERUSE WITH
molbox1+/molbox1+S™6.01
2016.12.16
molbox1+/molbox1+S
This flash is intended ONLY for molbox1+ or molbox1+S with the Fluke Calibration logo:

molbox1+ or molbox1+S v6.01 Embedded Software/4000086_pccal_flukecal_logo_172p

on the front panel, serial number 2000 and above. Attempted use on any other molbox will result in an inoperable molbox unless the molbox1 hardware is upgraded to a molbox1+.

For a molbox1 WITHOUT the Fluke Calibration logo, serial numbers 320 to 1500, please use the most recent
molbox1 firmware revision.
Instructions:
Download the file.

Run Winflash and select the file downloaded as the file to write to the product.

Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.

The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center.

If the update isn't performed properly, your product will be inoperable until it is.
Updates Include:
Rev 6.01 (2016 Dec 16)
FIX (MBOX-367): Password entry screen corrupted in user level menu.

Rev 6.00b (2011 Oct 11)
CHG (MBOX-235): Reynolds limit can now be factory modified on a case by case, molbloc by molbloc basis to handle special calibrations rather than using a global limit for all molblocs.
FIX (MBOX-233): If an uncalibrated gas was selected, certain enhanced factory features of the default molbloc calibration in N2 or Air were being used causing undesired results.
FIX (MBOX-232) : Switching to/from a molbloc-L to/from a molbloc-S and using the "DEVICE=EXT" command to reload the molbloc without powering down the molbox would not fully convert the molbox operation to the new molbloc type causing unexpected behavior.
FIX (MBOX-229) : For molbox1+ type "named cal" molbloc-L's that were newly initialized or restored using a restore file, an important internal calculation was not being made until a factory level command was used which could lead to a flow calculation error.

Rev 6.00a (2010 Apr 15)
CHG (MBOX-224): The '6' key incorrectly accesses the Display menu when the molbox is in remote mode.
CHG (MBOX-223): The correct mathematical model is not used when a molbloc is calibrated downstream.
Chatee con nuestroasistente de Fluke
Borrar el chat