Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 98.55ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.) - 1

Key Features

  • Three ranges
    • 30 A
    • 300 A
    • 3000 A, 1, 10 or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm (7 in.)
  • CAT III 600 V safety rating

Also available in pack of 4 for use in Power Quality Analyzers. Click here for more info.

Product overview: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)

The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Specifications: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)

Electrical Specification
Current ranges30 A
300 A
3000 A
AC rms
Output sensitivity (AC-coupled)100 mV
10 mV
1mV per A
Load impedance100 kΩ minimum
Accuracyat +25°C: ±1% of range (45 Hz to 65 Hz)
Linearity10% to 100% of range: ±0.2% of reading
Noise8 mV AC rms (30 A)
2 mV AC rms (300 A, 3000 A)
Frequency range10 Hz to 50 kHz (-3 dB)
Phase error< ±1° (45 Hz to 65 Hz)
±10° (at 20 kHz)
Position sensitivity (with cable > 25 mm from the coupling)

Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.

External wire influence: 1% (-40 db) of external current >200 mm from head.

External fieldwith cable > 200 mm from the head: ±1% of range
Power supply2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator
Temperature coefficient±0.08% of reading per °C
Working voltagesee Safety standards section: 600 V AC rms or DC
General Specifications
Head circumference915 mm (36 in.)
Head cable diameter14.3 mm (0.56 in)
Head bend radius38.1 mm (1.5 in)
Cable length (head to electronics)2 m (6.56 ft)
Output connection0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
Operating temperature range-20°C to +90°C (-4°F to 190°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Storage temperature range-40°C to +105°C (-40°F to 221°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Operating humidity15% to 85% (non-condensing)
Weight180 g (0.396 lb) (head)
190 g (0.419 lb) (electronics)
Safety standardsBS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
EMC standardsEN 61326: 1998 +A1, A2, and A3
Head cable length (double insulated)610 mm or 914 mm, depending on model

Models: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)

Fluke i3000s Flex 36

AC Current Clamp, 915 mm (36 in.)


Buy it

Is the raw data of the sensor the time derivative of the magnetic flux or is it already integrated with respect to time to give the current? Must it be used with a scope, or can be connected to a different DAQ device?

Asked by: Yahav
  • y_2024, m_11, d_19, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_3739330412596, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 160.36ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 99.3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat