Fluke 15B MAX Economical Digital Multimeter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 197.98ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 15B MAX 1500x1000 -01
  • 15B MAX 1500x1000 -02
  • 1XB MAX Test Pen 1500x1000

Key features

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V

Product overview: Fluke 15B MAX Economical Digital Multimeter

Fluke 15B MAX Inherits and continues the classic design of 15B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.

Audible and visual alarm for incorrect connections
Audible and visual alarm for incorrect connections
Test leads with fines tips for circuit board testing
Test leads with fines tips for circuit board testing

Specifications: Fluke 15B MAX Economical Digital Multimeter

Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
FunctionRangeResolutionAccuracy
15B MAX17B MAX
AC Volts (40 Hz to 500 Hz)16.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 31.0 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 33.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 30.5 % + 3
DC Millivolts600.0 mV0.1 mV1.0 % + 101.0 % + 10
AC Current μA (40 Hz to 400 Hz)2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 31.5 % + 3
AC Current mA (40 Hz to 400 Hz)240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 31.5 % + 3
AC Current A (40 Hz to 400 Hz)24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 31.5 % + 3
DC Current μA2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 31.5 % + 3
DC Current mA240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 31.5 % + 3
DC Current A24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 31.5 % + 3
Diode Test32.000 V0.001 V10%10%
Temperature 450.0 °C to 400.0 °C
0 °C to 50.0 °C
-55.0 °C to 0 °C
0.1 °CNA2 %+1 °C
2 °C
9 %+2 °C
Resistance (Ohms)5400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance640.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
2000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1 (10 Hz to 100 kHz)50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA0.1 % + 3
Duty Cycle11% to 99%0.10%NA1 % typical7
Continuity Threshold70Ω70Ω
BacklightYesYes
1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
4Use Type K thermocouple
5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
Input Characteristics
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection RatioNormal Mode Rejection Ratio
AC Volts1000 V 1>10 MΩ, <100 pF>60 dB at 50 Hz or 60 Hz
AC Millivolts1000 V 1>1 MΩ, <100 pF>80 dB at 50 Hz or 60 Hz
DC Volts1000 V 1>10 MΩ, <100 pF>100 dB at 50 Hz or 60 Hz>60 dB at 50 Hz or 60 Hz
DC Millivolts1000 V 1>1 MΩ, <100 pF>80 dB at 50 Hz or 60 Hz
1106 V Hz max
General Specifications
Maximum voltage between any Terminal and Earth Ground600 V
Maximum differential voltage between V and COM terminals1000V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AA, IEC LR6
Battery life500 hours minimum
TemperatureOperating 0 °C to 40 °C;
Storage -30 °C to 60 °C
Relative HumidityOperating Humidity Non-condensing
(<10 °C); ≤90 % RH at 10 °C to 30 °C;
≤75 % RH at 30 °C to 40 °C
Operating Humidity, 40 MΩ range≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
AltitudeOperating 2000 m; Storage 12000 m
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V, fast-blow, use only Fluke
specified parts. 11 A, 1000 V, fast-blow,
use only Fluke specified parts
Size (HxWxL)183 mm x 91 mm x 49.5 mm
Weight455 g
Ingress ProtectionIP40
SafetyIEC 61010-1, IEC61010-2-030: CAT III
600 V, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326-1: Portable
Electromagnetic Compatibility (EMC)Only applicable in Korea

Class A Equipment (Industrial Broadcasting & Communication Equipment)1
1Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

Models: Fluke 15B MAX Economical Digital Multimeter

Fluke 15B MAX-01 Digital Multimeter

Buy it

Includes:

  • TL75 Test Leads with 2 Protective Caps
  • 2 AA Batteries
Fluke 15B MAX-02 Digital Multimeter

Buy it

Includes:

  • TL31 Extra-Slim Test Leads with 2 Protective Caps
  • 2 AA Batteries
  • Safety information
Fluke 15B MAX KIT Digital Multimeter

Buy it

Includes:

  • TL75 Test Leads with 2 Protective Caps
  • TL31 Extra-Slim Test Leads with 2 Protective Caps
  • 2 AA Batteries
  • Safety information
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 152.19ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.15ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.