Fluke 101 Digital Multimeter
Key features
- Basic dc accuracy 0.5%
- CAT III 600 V safety rated
- Diode and continuity test with buzzer
- Small lightweight design for one-handed use
- Rugged, durable design
- Automatic shutdown
- Battery is easy to replace
Product overview: Fluke 101 Digital Multimeter
Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians. This small, lightweight multimeter fits comfortably in your hand but is rugged enough to withstand daily use for years to come. When it comes to professional-grade affordable multimeters, the Fluke 101 digital multimeter is your best choice.
Specifications: Fluke 101 Digital Multimeter
Electrical Specifications | ||
V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V | |
Accuracy | 3.0%±3 digit 1.0%±3 digit | |
V DC | Range | 6.000 V 60.00 V 600.0 V |
Resolution | 0.001 V 0.01 V 0.1 V | |
Accuracy | 0.5%±3 digit | |
Resistance Ohms | Range | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | |
Accuracy | 0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit | |
Capacitance | Range | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000.0 μF |
Resolution | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | |
Frequency (10 Hz – 100 kHz) | Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | |
Duty Cycle | Range | 0.1 % to 99.9 % |
Resolution | 0.1 % | |
General Specifications | ||
CAT Rating | CAT III 600 V | |
V AC Range | 600.0 V | |
V DC Range | 600.0 V | |
Ohms Range | 40.00 MΩ | |
Auto Shutoff | Y | |
Continuity | Y | |
Capacitor | 100.0 μF | |
Frequency | 100.0 kHz | |
Hold | No | |
Duty Cycle | Yes | |
Size | 130 mm x 65 mm x 27mm | |
Weight | 160 g | |
Battery | Two AAA | |
Warranty | 1 year | |
Environmental Specifications | ||
Operating Temperature | 0 °C to +40 °C | |
Storage Temperature | -30 °C to +60 °C | |
Operating Humidity | Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without Condensation) | |
Operating Humidity, 40 MΩ | 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C | |
Operating Altitude | 2,000 meters | |
Storage Altitude | 12,000 meters | |
IP Rating | IP 40 per IEC 60529 | |
Vibration Requirements | MIL-PRF-28800F, Class 2 | |
Drop Test Requirements | -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. | |
EMI, RFI, EMC | Must meet all applicable requirements in IEC/EN 61326-1 | |
Absorption/Corrosion | Per Fluke SOP 39.1 | |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC |
Models: Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter