Ti95 Fluke Connect FCA Kit

Model#:FLK-Ti95 9HZ/FCAPart#:4474228UPC#:0 95969 72484 5
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 336.16ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Ti95 Fluke Connect FCA Kit
  • Fluke Ti95 Fluke Connect FCA Kit
  • Ti95 Fluke Connect FCA Kit
  • Fluke Ti95 Fluke Connect FCA Kit
Discontinued

Key features

The Fluke Ti95 Infrared Camera offers:

  • The only wireless industrial infrared camera in its price class¹ – take advantage of the benefits of Fluke Connect® by seamlessly gathering and sharing inspection results instantly
  • Superior image quality, up to 23% better spatial resolution than other competitive models in this price class¹
  • 80x80 resolution
  • Removable 8 GB SD Memory Card
  • 8 GB Fluke Connect® wireless SD Card
  • Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
  • 2 megapixel built-in digital camera
  • Large 3.5 inch LCD - 32% larger screen than other competitive models lets you clearly see what you are measuring
  • Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
  • Rugged, lightweight, point–and–shoot infrared camera

The Fluke 3000 FC Series Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3001 FC Wireless iFlex™ AC Current Module offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap

¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

This product is discontinued or reclassified

Product overview: Ti95 Fluke Connect FCA Kit

Fluke Connect®

See How It Works
Fluke Connect FAQs

Troubleshooting just got easier with the Ti95 Fluke Connect FCA Kit with Ti95 Infrared Camera, 3000 FC DMM, and a3001 FC iFlex® Module. This kit features the only wireless industrial infrared camera in its price class¹, the Ti95. Safely capture AC current measurements with your a3001 FC iFlex Module from up to 20 meters away on the 3000 FC DMM, while simultaneously conducting an infrared inspection with your Ti95 infrared camera. Upload your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

Specifications: Ti95 Fluke Connect FCA Kit

Fluke Ti95 Infrared Camera

Key Features
IFOV (spatial resolution)5.6 mRad
Resolution80 x 80 (6,400 pixels)
Field of view26° H x 26° V
Wireless connectivityYes
Fluke Connect™ app compatibleYes, with included wireless SD card (where available)
IR-Fusion® technologyPIP (46 cm (18 in) and beyond)
Focus systemFixed focus 46 cm (18 in) and beyond
Ruggedized display3.5 inch diagonal (portrait format)
Rugged, ergonomic design for one-handed useYes
Thermal sensitivity (NETD)≤ 0.10°C at 30°C target temp (100 mK)
Temperature measurement range (not calibrated below -10°C)-20°C to +250°C (-4°F to +482°F)
Level and spanSmooth auto and manual scaling
Fast auto toggle between manual and auto modesYes
Fast auto-rescale in manual modeYes
Minimum span (in manual mode)2.5°C
Minimum span (in auto mode)5°C
Built-in digital camera (visible light)2 megapixel industrial performance
Frame rate9 Hz only
Data Storage and Image Capture
Extensive SD memory systemRemovable 8 GB SD memory card and 8 GB wireless SD card (where available)
Direct download via USB-to-PC connection
Image capture, review, save mechanismOne-handed image capture, review, and save capability
File formats imageNon-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp, .jpg) files
Memory reviewThumbnail view navigation and review selection
SoftwareSmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software
Export file formats with SmartView® softwareBMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Battery
Batteries (field-replaceable, rechargeable)One lithium ion smart battery pack with five-segment LED display to show charge level
Battery lifeFour+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
Battery charge time2.5 hours to full charge
AC battery charging systemIn-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter.
AC operationAC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
Power savingUser selectable sleep and power off modes
Temperature Measurement
Accuracy±2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correctionYes (both number and table)
On-screen reflected background temperature compensationYes
Color Palettes
Standard palettes6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale
General Specifications
Infrared spectral band9 μm to 15 μm (long wave)
Operating temperature-10°C to +50°C (14°F to 122°F)
Storage temperature-20°C to +50°C (-4°F to 122°F)
Relative humidity10% to 95%, non-condensing
Center-point temperature measurementYes
Spot markersHot and cold spot markers
Center box (MIN-MAX-AVG)Fixed-size measurement box with MIN-MAX-AVG temp
Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibilityEN 61326-1:2006 IEC 61326-1:2005
C TickIEC/EN 61326-1
US FCCEN61326-1; FCC Part 5
Vibration2G, IEC 68-2-6
Shock25G, IEC 68-2-29
DropEngineered to withstand 2 meter (6.5 feet) drop
Size (H x W x L)28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
Weight (battery included)0.726 kg (1.6 lb)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard), extended warranties are available
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
 

Fluke 3000 FC Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 445 Hz to 500 Hz1.0 % + 3
500 Hz to 1 kHz2.0% + 3
1. All AC voltage ranges are specified from 1 % of range to 100 % of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mVRange / Resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / Resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Range / Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / Resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy1.5% + 3
mA DC 2Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5 % of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩTypical short circuit current
1100 Vrms< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools
 

Fluke a3001 FC Wireless iFlex® AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Models: Ti95 Fluke Connect FCA Kit

FLK-Ti95 9HZ/FCA
FLK-Ti95 9HZ/FCA
Part#: 4474228
UPC#: 0 95969 72484 5

Includes:

  Fluke Ti95 Thermal Imager:
  • AC power adapter
  • Lithium ion smart battery (1)
  • USB cable
  • SD memory card
  • Fluke Connect™ wireless SD Card (where available, shipped separately in non-European countries)
  • Soft transport bag
  • Adjustable hand strap (left- or right-handed use)
  • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
  • SmartView® software
  • Warranty registration card

Fluke 3000 FC Wireless Digital Multimeter with three AA batteries - installed:
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack

Fluke a3001 FC Wireless iFlex AC Current Module with two AA batteries - installed:
  • iFlex 10"" coil (1)
  • Magnet/strap (1)
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 183.69ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 97.71ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat