Fluke CNX™ Ti125 Industrial System

Model#:TI125 CNX KITPart#:4362590UPC#:0 95969 67703 5
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 49.87ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke CNX™ Ti125 Industrial System 1
  • Fluke CNX™ Ti125 Industrial System 2
  • Fluke CNX™ Ti125 Industrial System 3
  • Fluke CNX™ Ti125 Industrial System 4
Discontinued

Key features

Get all the information you need to quickly troubleshoot problems with the Fluke Ti125 CNX Industrial Kit.

The Ti125 Offers:

  • IR-Fusion® with AutoBlend- blends a digital and partially transparent IR image into a single image, making problem detection fast and easy.
  • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
  • IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
  • Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
The CNX™ i3000 iFlex AC Wireless Current Module Offers:
  • True-rms AC current measurements to 2500 A
  • 3% accuracy
  • Memory recording up to 65,000 readings
  • iFlex® current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT III 1000, CAT IV 600 V
  • IP42
This product is discontinued or reclassified

Product overview: Fluke CNX™ Ti125 Industrial System

Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!

Specifications: Fluke CNX™ Ti125 Industrial System

Fluke Ti125 Infrared Camera
Detailed Specifications
IR resolution (FPA size)160 x 120 FPA Uncooled Microbolometer
Spectral band7.5 μm to 14 μm (long wave)
Capture or refresh rate9 Hz or 30 Hz versions
NETD (thermal sensitivity)≤ 0.10 °C at 30 °C target temp (100 mK)
 0.10 °C at 30 °C target temp (100 mK)
FOV (field of view)22.5 °H x 31 °V
IFOV (spatial resolution)3.39 mRad
Temperature measurement range (not calibrated below -10  °C)-20 °C to +350 °C (-4 °F to +662 °F)
Temperature measurement accuracy± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanismIR-OptiFlex™ focus system
IR-Fusion® technologyPIP, FULL IR, FULL VISIBLE, AutoBlend™
CNX™ wireless enabledYes
Color alarmsHigh temperature, low temperature, isotherm
Standard palettesBlue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Ultra Contrast™ palettesBlue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Hot/cold markersYes
User definable spot markersThree on camera and in SmartView®
Centerbox (MIN/AVG/MAX)Yes
Level and span controlManual and auto
Minimum span in auto mode5 °C
Minimum span in manual mode2.5 °C
Minimum IR focus distance15.25 cm (6 in)
Weight0.726 kg (1.6 lb)
Size28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display3.5 inch diagonal (portrait format)
Visible camera2 megapixel industrial-grade
Minimum automatic parallax correction~18-22 inches
IR-PhotoNotes™ annotation systemYes (3 images)
Laser pointerYes
TorchYes
Electronic (cardinal) compassYes
Emissivity correctionYes
Transmission correctionYes
Background (reflected) compensationYes
Voice annotation (audio)Yes (60 seconds) per image
Multi-mode video outputStreaming USB video output (infrared, visible and IR-Fusion modes)
Multi-mode video recording (standard avi w/ mpeg encoding)Yes (AVI with MPEG encoding, up to 5 minutes)
Multi-mode video recording (radiometric .Is3)Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
Memory reviewThumbnail review
Battery (field-replaceable, rechargeable)Two
Battery life4+ hours (each)*
External battery charging baseYes
Charging power supplyYes
Drop test2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529)IP 54
Recommended calibration cycleTwo-years
Multifunction card readerIncluded
Memory storage2 GB SD memory card
Direct download capabilityMini USB download direct to PC
Operating temperature range-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range-20 °C to +50 °C (-4 °F to 122 °F)
Operating humidityOperating and storage 10 % to 95 %, non-condensing
Vibration and shock2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C TickIEC/EN 61326-1
EMI, RFI, EMCEN61326-1; FCC Part 5
User manualsCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty periodTwo-years
Extended warranty and service plansYes

*Assumes 50% brightness of LCD

CNX™ 3000 Wireless Multimeter

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ResolutionAccuracy ² ³
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
Notes:
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
Ω600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
μF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF¹1 μF10 % typical
Notes:
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
FunctionRange ¹ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA ³0.1 mA
mA DC ²60.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
Notes:
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy ¹
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
Notes:
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC,
50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC,
50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open Circuit Test VoltageFull ScaleTypical Short Circuit Current
1100 V RMS< 2.7 V DCTo 6 MΩ: < 0.7 V DC
50 MΩ: < 0.9 V DC
< 350 mA
1100 V RMS< 2.7 V DCTo 6 MΩ: 2.000 V DC< 1.1 mA
FunctionOverload ProtectionOverload
mAFused, 44/100 A,
1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (HxWxL)4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54
Notes:
• Accuracy is specified as ± ([% of reading] + [number of least significant digits]).
• All ranges are autoranging.
• Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

Fluke CNX™ i3000 iFlex AC Wireless Current Module

Specifications
Range2500 A AC
Resolution0.1 A to 999.9, 1A from 1000 to 2500
Accuracy3 % ± 5 digits
Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display3-1/2 digits, LCD w/backlight
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication range20 Meters
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
EMCEN 61326-1:2006
Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree2
Temperature coefficientAdd 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C)
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP42
Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
Jaw opening25.4 cm (10 in) coil

Fluke CNX™ v3000 AC Wireless Voltage Module

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage
Range ¹ResolutionAccuracy ² ³
45  Hz to 500 Hz500 Hz to 1 kHz
6.000 V0.001 V1.0 % + 32.0 % + 3
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
Notes:
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
General Specifications
LCD w/backlight3½ digits, 6000 counts, updates 4/sec
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
Unbound listen interval5 seconds
RF communications2.4 GHZ ISM Band
RF communication range20 Meters
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
EMCEN 61326-1:2006
Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
Pollution degree2
Temperature coefficient0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP42
Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)

Models: Fluke CNX™ Ti125 Industrial System

TI125 CNX KIT
Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. 
Part#: 4362590
UPC#: 0 95969 67703 5
Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 53.02ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.15ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke CNX™ Ti125 Industrial System

Chat with ourFluke assistant
Clear Chat