Fluke CNX™ Ti125 Industrial System
Key features
Get all the information you need to quickly troubleshoot problems with the Fluke Ti125 CNX Industrial Kit.
The Ti125 Offers:
- IR-Fusion® with AutoBlend- blends a digital and partially transparent IR image into a single image, making problem detection fast and easy.
- Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
- IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
- Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
- Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
- True-rms AC current measurements to 2500 A
- 3% accuracy
- Memory recording up to 65,000 readings
- iFlex® current probe allows you to get into tight, awkward spaces
- Backlit LCD display
- CAT III 1000, CAT IV 600 V
- IP42
Product overview: Fluke CNX™ Ti125 Industrial System
Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!
Specifications: Fluke CNX™ Ti125 Industrial System
Detailed Specifications | |
IR resolution (FPA size) | 160 x 120 FPA Uncooled Microbolometer |
Spectral band | 7.5 μm to 14 μm (long wave) |
Capture or refresh rate | 9 Hz or 30 Hz versions |
NETD (thermal sensitivity) | ≤ 0.10 °C at 30 °C target temp (100 mK) 0.10 °C at 30 °C target temp (100 mK) |
FOV (field of view) | 22.5 °H x 31 °V |
IFOV (spatial resolution) | 3.39 mRad |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +350 °C (-4 °F to +662 °F) |
Temperature measurement accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
Focus mechanism | IR-OptiFlex™ focus system |
IR-Fusion® technology | PIP, FULL IR, FULL VISIBLE, AutoBlend™ |
CNX™ wireless enabled | Yes |
Color alarms | High temperature, low temperature, isotherm |
Standard palettes | Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber |
Ultra Contrast™ palettes | Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber |
Hot/cold markers | Yes |
User definable spot markers | Three on camera and in SmartView® |
Centerbox (MIN/AVG/MAX) | Yes |
Level and span control | Manual and auto |
Minimum span in auto mode | 5 °C |
Minimum span in manual mode | 2.5 °C |
Minimum IR focus distance | 15.25 cm (6 in) |
Weight | 0.726 kg (1.6 lb) |
Size | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
LCD display | 3.5 inch diagonal (portrait format) |
Visible camera | 2 megapixel industrial-grade |
Minimum automatic parallax correction | ~18-22 inches |
IR-PhotoNotes™ annotation system | Yes (3 images) |
Laser pointer | Yes |
Torch | Yes |
Electronic (cardinal) compass | Yes |
Emissivity correction | Yes |
Transmission correction | Yes |
Background (reflected) compensation | Yes |
Voice annotation (audio) | Yes (60 seconds) per image |
Multi-mode video output | Streaming USB video output (infrared, visible and IR-Fusion modes) |
Multi-mode video recording (standard avi w/ mpeg encoding) | Yes (AVI with MPEG encoding, up to 5 minutes) |
Multi-mode video recording (radiometric .Is3) | Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene |
Memory review | Thumbnail review |
Battery (field-replaceable, rechargeable) | Two |
Battery life | 4+ hours (each)* |
External battery charging base | Yes |
Charging power supply | Yes |
Drop test | 2 meter (6.5 feet) |
Ingress protection (IP) rating (IEC 60529) | IP 54 |
Recommended calibration cycle | Two-years |
Multifunction card reader | Included |
Memory storage | 2 GB SD memory card |
Direct download capability | Mini USB download direct to PC |
Operating temperature range | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature range | -20 °C to +50 °C (-4 °F to 122 °F) |
Operating humidity | Operating and storage 10 % to 95 %, non-condensing |
Vibration and shock | 2G, IEC 68-2-26 and 25G, IEC 68-2-29 |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
C Tick | IEC/EN 61326-1 |
EMI, RFI, EMC | EN61326-1; FCC Part 5 |
User manuals | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian |
Standard warranty period | Two-years |
Extended warranty and service plans | Yes |
*Assumes 50% brightness of LCD
CNX™ 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | ||||
AC Voltage | ||||
Range ¹ | Resolution | Accuracy ² ³ | ||
45 Hz to 500 Hz | 500 Hz to 1 kHz | |||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 | |
6.000 V | 0.001 V | |||
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | |||
Notes: ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. | ||||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 | |
V | 6.000 V | 0.001 V | 0.09 % + 2 | |
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | 0.15 % + 2 | ||
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 | |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | ||
60.00 kΩ | 0.01 kΩ | |||
60.00 kΩ | 0.1 kΩ | |||
600.0 kΩ | 0.001 MΩ | |||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | ||
Diode test | 2.000 V | 0.001 V | 1 % + 2 | |
μF | 1000 nF | 1 nF | 1.2 % + 2 | |
10.00 μF | 0.01 μF | |||
100.0 μF | 0.1 μF | |||
9999 μF¹ | 1 μF | 10 % typical | ||
Notes: ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. | ||||
AC and DC Current | ||||
Function | Range ¹ | Resolution | Accuracy | |
mA AC (45 Hz to 1 kHz) | 60.00 mA | 0.01 mA | 1.5 % + 3 | |
400.0 mA ³ | 0.1 mA | |||
mA DC ² | 60.00 mA | 0.01 mA | 0.5 % + 3 | |
400.0 mA | 0.1 mA | |||
Notes: ¹ All AC current ranges are specified from 5 % of range to 100 % of range. ² Input burden voltage (typical): 400 mA input 2 mV/mA. ³ 400.0 mA accuracy specified up to 600 mA overload. | ||||
Frequency | ||||
Range | Resolution | Accuracy ¹ | ||
99.99 Hz | 0.01 Hz | 0.1 % + 1 | ||
999.9 Hz | 0.1 Hz | |||
9.999 kHz | 0.001 kHz | |||
99.99 kHz | 0.01 kHz | |||
Notes: ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||||
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (nominal) | Common Mode Rejection Ratio (1 kΩ unbalance) | Normal Mode Rejection |
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | ||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | Full Scale | Typical Short Circuit Current | ||
1100 V RMS | < 2.7 V DC | To 6 MΩ: < 0.7 V DC 50 MΩ: < 0.9 V DC | < 350 mA | |
1100 V RMS | < 2.7 V DC | To 6 MΩ: 2.000 V DC | < 1.1 mA | |
Function | Overload Protection | Overload | ||
mA | Fused, 44/100 A, 1000 V FAST Fuse | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. | |||
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. | |||
General Specifications | ||||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts | |||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |||
Battery life | 300 hours minimum | |||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C | |||
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) | |||
Altitude | Operating: 2,000 m Storage: 12,000 m | |||
Temperature coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
Wireless frequency | 2.4 GHz ISM Band 20 meter range | |||
Size (HxWxL) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) | |||
Weight | 340 g (12 oz) | |||
Safety standards | US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 | |||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS | |||
Ingress Protection (IP) rating | IP54 | |||
Notes: • Accuracy is specified as ± ([% of reading] + [number of least significant digits]). • All ranges are autoranging. • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C. |
Fluke CNX™ i3000 iFlex AC Wireless Current Module
Specifications | |
Range | 2500 A AC |
Resolution | 0.1 A to 999.9, 1A from 1000 to 2500 |
Accuracy | 3 % ± 5 digits |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
Display | 3-1/2 digits, LCD w/backlight |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | 20 Meters |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Operating humidity | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C |
EMC | EN 61326-1:2006 |
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002 |
Pollution degree | 2 |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C) |
Safety rating | CAT IV 600 V, CAT III 1000 V |
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP42 |
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22 kg (8 oz) |
Jaw opening | 25.4 cm (10 in) coil |
Fluke CNX™ v3000 AC Wireless Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage | |||
Range ¹ | Resolution | Accuracy ² ³ | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
6.000 V | 0.001 V | 1.0 % + 3 | 2.0 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
Notes: ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. | |||
General Specifications | |||
LCD w/backlight | 3½ digits, 6000 counts, updates 4/sec | ||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | ||
Battery life | 400 hours | ||
Memory | Record up to 65,000 readings | ||
Unbound listen interval | 5 seconds | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | 20 Meters | ||
Operating temperature | -10 °C to +50 °C | ||
Storage temperature | -40 °C to +60 °C | ||
Operating humidity | 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C | ||
EMC | EN 61326-1:2006 | ||
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 61010-031:2002+A1:2008 | ||
Pollution degree | 2 | ||
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C) | ||
Safety rating | CAT IV 600 V, CAT III 1000 V | ||
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS | ||
Ingress Protection (IP) rating | IP42 | ||
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) | ||
Weight | .22 kg (8 oz) |
Models: Fluke CNX™ Ti125 Industrial System
UPC#: 0 95969 67703 5
Manuals + resources: Fluke CNX™ Ti125 Industrial System
- Connecting a thermal imager to your iPhone
- Connecting multiple tools at the same time with Fluke Connect®
- Connecting the T3000 FC with the Fluke Connect™ app
- Fluke infrared camera: electronic compass
- Fluke Infrared Camera: IR-Fusion® Technology
- Fluke Infrared Cameras: LaserSharp® Auto Focus
- Fluke IR-PhotoNotes<sup>™</sup>: Annotation System
- Fluke smartview 3d-IR: IR analysis and reporting software
- Fluke Thermal Imaging a 360 Degree Overview
- Fluke Thermal Imaging for Building Inspectors - Building Envelope
- Fluke Thermal Imaging: For Building Inspectors - HVAC
- Fluke Thermal Imaging: For Building Inspectors - Introduction
- Fluke Thermal Imaging: For Building Inspectors - Moisture
- Fluke Thermal Imaging: For Building Inspectors - Technology
- Fluke thermal imaging: just another day on the job
- How to create an equipment baseline with EquipmentLog™ history
- How to email a measurement using the Fluke Connect app
- How to record measurements and graphs
- How to save measurements to EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- How to Use IR Fusion with a Thermal Imager
- How to Use IR Photonotes and Audio Notes on a Ti125
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- Measurement history in one place using EquipmentLog™ history
- Measuring from a safe distance using the Fluke Connect™ app
- Performing predictive maintenance with Fluke Connect™
- Saving measurements with AutoRecord™ measurements
- Share equipment health with EquipmentLog™ history
- Thermal Imagers for Building Inspectors - Commercial Properties
- Thermal Imaging CNX™: Set-Up is Easy 123 Video, Set-Up Your Thermal Imager to CNX Modules
- Ti400 LaserSharp<sup>®</sup> Auto Focus
- Using ShareLive™ video call to share live measurements and video
- Viewing and graphing three phase measurements
- What is Fluke Connect®