Fluke ii905 Acoustic Imager

Model#:FLK-II905Part#:5594650
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 127.34ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke ii905 Acoustic Imager
  • Fluke ii905 Acoustic Imager
  • Fluke ii905 Acoustic Imager
  • Fluke ii905 Acoustic Imager

Key features

  • Easy, fast, and safe visual detection of compressed gas leaks with LeakQ™️ mode including estimated leak size and cost.
  • The 7" LCD touchscreen overlays a SoundMap™️ on visual images, facilitating rapid leak location identification.
  • The integrated visual- and textual tagging and annotation functionalities offer important details to optimize reporting and follow-up actions.
  • On-the-go wireless upload to Fluke Connect
In stock
$19,999.99
FREE Shipping
30-day Returns

Product overview: Fluke ii905 Acoustic Imager

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

Fluke ii905 Acoustic Imager with LeakQ™: Detect, Locate, and Assess Gas Leaks

The Fluke ii905 Acoustic Imager equipped with LeakQ™ acoustic leak detection technology empowers maintenance teams to efficiently detect, locate, and assess gas and vacuum leaks. Whether you're dealing with compressed air systems, pipelines, or industrial equipment, the Fluke ii905 provides valuable insights to optimize your operations.

Key Features:

  • Ready-to-Use: The Fluke ii905 comes ready out of the box. Its rugged, ergonomic design ensures easy handling, while the large 7" LCD display provides clear leak visualization.
  • Quick Detection: Even users with minimal experience can start detecting leaks within minutes. The tool estimates leak size and cost, incorporating a new distance-estimation feature and the 1-10 LeakQ™ severity index.
  • SoundMap™ Overlay: The 7" LCD touchscreen overlays a SoundMap™ on visual images, facilitating rapid leak location identification.
  • Intuitive Interface: Easily isolate leak sound frequencies and filter out background noise.
  • Tagging and Organization: Use image and video tagging, annotation, and folders for efficient organization.
  • Leak Sizing: Prioritize repairs based on leak size.
  • Collaboration: The reporting tool allows seamless sharing of visuals, tagging, and notes with team members and repair personnel.

Money-Saving Insights:

Did you know that a 100 hp air compressor can consume around $50,000 in electricity annually? Shockingly, up to 30% of that electricity is wasted due to pressurizing airlines that leak. Many facilities overlook assessing the efficiency of their compressed air systems, leading to unnecessary capacity additions. The Fluke ii905 helps you identify leaks, optimize energy usage, and reduce costs.

LeakQ™ Mode:

Automatic Distance Estimation: When a leak is detected, the imager determines the distance to the target (indicated inside the circle on the display). The LeakQ value on the screen reflects the leak's size, based on measured dB SPL value and distance.

Comprehensive Reporting:

The LeakQ reporting tool combines data from your Fluke ii905 Acoustic Imager with direct inputs to create organized and detailed reports. These reports guide repairs, confirm fixes post-repair, and document the inspection process and results.

LeakQ online reporting tool

  • Local PC installed application
  • No Leak Type selection (should be included at the time of capturing the measurement)
  • Offers customization of reporting template

LeakQ report

Industrial imaging virtual demo

What’s the Best Acoustic Imager for my needs?

The following table highlights the main differences between the Fluke acoustic cameras. Please see the datasheet for a complete comparison of specifications.

 
 Fluke ii500 Acoustic ImagerFluke ii905 Acoustic ImagerFluke ii915 Acoustic Imager
LeakQ™Scale (1-10)Leak size scale, leak rate, and leak cost estimationLeak size scale, leak rate, and leak cost estimation
PDQ™  
MecQ™  
Features   
WiFi / Bluetooth 
Frequency2 to 52 kHz2 to 65 kHz2 to 100 kHz
Detection rangeUp to 50 m (164 ft)*Up to 70 m (230 ft)*Up to 120 meters (393 ft)*
Resolution0.3 MP5.0 MP5.0 MP
Battery life6 hours6 hours6 hours
Memory20 GB  
(>
5000 pictures / > 999 videos)
32 GB  
(> 8000 pictures / > 1600 videos)
32 GB  
(> 8000 pictures / > 1600 videos)
Tripod connector  

*Depending on ambient conditions

What's in the box:

  • Fluke ii905 Acoustic Imager
  • USB-C Charger with country-specific connectors
  • Rugged lithium-ion smart battery pack
  • USB-C cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap
  • Sensor array protector

Specifications: Fluke ii905 Acoustic Imager

Specifications
Sensors
Frequency band2 kHz to 65 kHz
Detection range10.5 to > 70 meters
(1.6 to > 230 feet)
Field of view (FOV)63°± 5°
Nominal frame rate25 FPS
Built-in digital camera (visible light)
Field of view (FOV)63°±5°
FocusFixed lens
Zoom3 x digital zoom
Resolution5 MP
Display
Size7" LCD with backlight, sunlight readable
Resolution1280 x 800 (1,024,000 pixels)
TouchscreenCapacitive
Acoustic imageSoundMapTM  image
Image storage 
Storage capacity32 GB
(> 8,000 pictures / > 1,600 videos)
Image formatBlended visual and SoundMapTM  .JPG or .PNG
Video formatBlended visual and SoundMapTM  .MP4
Video lengthUp to 5 minutes
Digital exportUSB-C for data transfer
Acoustic measurements 
Measurement range (typical)15.4 to 115.2 dB SPL
(± 1 dB SPL 2 kHz)
5.6 to 102.5 dB SPL
(± 2 dB SPL 19 kHz)
28.4 to 131.1 dB SPL
(± 1 dB SPL 35 kHz)
41.8 to 133.1 dB SPL
(± 3 dB SPL 52 kHz)
Classification and quantification
LeakQTMLeak size scale, Leak rate, and Leak cost estimation
PDQ ModeTM
MecQTM
Auto max/min dB gainAuto or manual, user selectable
Frequency band selectionUser selectable through user-made presets or manual entry
Battery 
BatteryRechargeable and field replaceable Li-ion battery
Battery life6 hours
Battery charging time~3,5 hours
Battery charging systemInternal (USB-C)
Software
Ease of useIntuitive user interface
Acoustics: Show dB scaleOn/Off
Acoustics: Min/Max dBManual/Auto
Acoustics: ProfilesPreset capture profiles
Acoustics: High frequency
Acoustics: Multiple sourcesShow single or multiple sources
Palette: Colors3: Grayscale, Ironbow, and Blue-Red
Palette: Overly transparencyYes: 1-100%
Grayscale modeYes
Centerpoint markersOn/Off
Trend graphsFrequency and dB scale
SpotmarkersdB level reading at center point of image
Leak valuesLeak costs, Leak volume, LeakQTM  scale (1-10)2
Master admin menuYes
AnnotationAsset name; Asset ID; Asset type; Leak type; Gas type; Pressure
Photo notesUp to 4 photos notes for reference
Asset inspection status'As left', 'As found', 'Undetermined'
Asset IDText input and automatic QR code based asset ID identification
Actions annotationAction requirements, Action priority level, Action notes
OtherOperating conditions, Weather notes
General specifications
Tripod holder / connectorYes: 1/4"-20
USB2 x USB-C
WirelessWifi
Operating Temperature-10 to 40 °C (14 to 104 °F)
Storage Temperature-20 to 70 °C (-4 to 158 °F) without batteries installed
Relative humidity10 to 95 % non-condensing
Size (H x W x L)186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included)2 kg (4.4 pounds)
Ingress Protection (IP)IP40
Warranty2 year
Fluke Premium CarePremium Care Standard3
Self-diagnostic notificationArray-health test to identify when microphone array needs attention
Supported languagesDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliantYes
Safety 
General safetyIEC 61010-1
Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting and Communication)
USA (FCC)47 CFR 15 sub part B. This product is considered an exempt device per clause 15.103
¹ Depending on ambient conditions
² 1-10 Scale (independent of Leak Type)
³ Subject to regional availability (www.fluke.com/premiumcare)

Models: Fluke ii905 Acoustic Imager

FLK-II905

Fluke ii905 Acoustic Imager

Part#: 5594650

Includes:

  • Fluke ii905 Acoustic Imager
  • USB-C Charger with country-specific connectors
  • Rugged lithium-ion smart battery pack
  • USB-C cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap
  • Sensor array protector
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 202.08ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.04ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat