Fluke 190 Series III ScopeMeter® Test Tools

Model#:ScopeMeter 190-062-III Test ToolPart#:5282331UPC#:1 95112 02177 4
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.17ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 190-504 Series III Portable Oscilloscope
  • Fluke 190-504 Series III Handheld Oscilloscope
  • CAT III 1000 V/CAT IV 600 V rated portable oscilloscope
  • Four channel portable handheld oscilloscope

Key features

  • Rated for industrial environments CAT III 1000 V/CAT IV 600 V
  • Automatically capture, view and analyze complex waveforms
  • Large, bright color display for easy in-the-field viewing
  • USB and Wi-Fi download for analyzing data with FlukeView® software
  • Up to four independent floating isolated inputs, up to 1000 V
In stock
$4,313.99
Now with Care Plan options
FREE Shipping
30-day Returns
Product + Premium Care Plan
Premium Care Plan only (I already own the product)
No thanks

Product overview: Fluke 190 Series III ScopeMeter® Test Tools

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

High performance portable oscilloscopes engineered for harsh environments

Fluke 190 Series III ScopeMeter® Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining industrial machinery, automation and process controls, and power conversion electronics with ease—from DC to 500 MHz.

Choose from two or four channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances. Perform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot™ Paperless Recorder, ScopeRecord™ Mode, Connect-and-View™ Triggering and a unique 100-screen Replay function help you quickly diagnose issues to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.

  • Up to four independent floating isolated inputs, up to 1000 V
  • Up to 5 GS/s real time sampling (depending on model and channels used)
  • Deep memory: 10,000 points per trace waveform capture (scope mode)
  • CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
  • Up to seven hours of battery operation using BP291
  • Large, bright color display is easy to view in nearly any environment
  • Easy to store and view historical data and transfer to a PC via USB or Wifi
  • Convenient battery access door for quick battery swaps in the field
  • IP51 rating, dust and drip-proof
  • Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency spectrum using FFT-analysis
  • Automatic capture and REPLAY of 100 screens
  • ScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis
  • TrendPlot Paperless Recorder mode with deep memory for long- term automatic measurements
  • 5,000 count DMM included in the 2-channel models

Measure from mV to kV safely

Independently isolated inputs allow you to make measurements in mixed circuits having different ground references reducing the risk of accidental short circuits. Conventional bench oscilloscopes without special differential probes and isolation transformers can only reference measurements to line power earth ground. ScopeMeter 190 Series III test tools are engineered to cover a wide application range from mV to kV, so you’re ready for anything from microelectronics to heavy-duty higher voltage electrical applications. 190 Series III 60MHz and 100MHz configurations include VPS421 100:1 probes for higher voltage applications, while the 200MHz and 500MHz configurations include VPS410-II 10:1 probes suitable for both microelectronics and higher voltage applications.

IP-51 rated for harsh environments

Rugged and shock-proof, ScopeMeter Test Tools are built for dirty, hazardous environments. With its sealed case, it can endure dust, drips, humidity and airborne pollutants. Every time you reach for ScopeMeter Test Tool you can be confident it will work reliably wherever your work takes you.

USB and Wi-Fi connectivity

The Fluke 190 Series III offers two USB ports, electrically isolated from measurement input circuits allowing you to quickly and easily transfer data to a PC, archive and share waveforms with OEMs, colleagues and support staff, or store waveforms, screen captures and instrument setups onto USB memory devices for later use. Easily transfer saved files via USB stick, direct connection via the USB interface or optional Wi-Fi connectivity. These files can be used for further data handling or in FlukeView-2 Software to study waveforms in greater detail.

Connect-and-View triggering

Connect-and-View triggering provides an instant, stable display without the need for adjusting set- tings. If you’ve used other scopes, you know how tricky triggering can be. If settings are incorrect, results can be unstable or incorrect. Connect-and-View automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable and repeatable display of virtually any signal including motor drive and control signals. It’s especially fast and convenient when you’re measuring a number of test points in rapid succession.

Connect and View captures even the most complex signals without requiring additional setup
The built-in multimeter provides convenient precision measurements

Built-in digital multimeter

Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter on two channel 190 Series III models. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.

ScopeRecord™ mode for high resolution waveform recording

ScopeRecord memory stores up to 30,000 or more data points per channel, capturing fast intermittent events and glitches as short as 8 ns. (Two sets of multiple channel recordings can be stored to internal memory for later analysis.)

  • Records events like UPS, power supply or motor start-up cycles
  • With the Stop on Trigger mode, the ScopeMeter Test Tool automatically recognizes a power failure and stores the waveform data preceding it
Capture high-resolution waveform details over extended period using ScopeRecord™ mode
Trend multiple measurements capturing signal intermittent events, signal drift or fluctuations

TrendPlot paperless recorder— records up to 11 days to help you find intermittent faults

The toughest faults to find are those that happen only once in a while. These intermittent events can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, dips, swells and interruptions, or the starting and stopping of a motor can also cause a machine to stop. You may not be around when it happens, but the Fluke 190 Series III ScopeMeter Test Tool will be.

  • Plot minimum and maximum peak values and average over time
  • Plot any combination of up to four readings including voltages, amps, temperature, frequency and phase for all inputs, all with time and date stamp to pinpoint faults

FlukeView™ 2 ScopeMeter software for documenting, archiving and analysis

Get more out of your ScopeMeter Test Tool with FlukeView 2 ScopeMeter Software for Windows.

  • Documentation—transfer waveforms, screens and data to your PC for printing or importing data into a report
  • Add text to ScopeMeter Test Tool settings—give operators guidance when recalling settings
  • Archive—create a library of waveforms for easy reference, or waveform comparison
  • Analysis—use cursors or export data to another analysis program
FlukeView-2 ScopeMeter software

What's in the box:

  • ScopeMeter Test Tool
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (4 pcs)
  • CXT293 carrying case
  • DWA-131 WiFi dongle (Part #4723989)
  • FlukeView Activation instructions (paper)
  • Printed instructions
*Included items vary based on model selected

Specifications: Fluke 190 Series III ScopeMeter® Test Tools

Oscilloscope Models
 190-062190-102190-202190-502190-104190-204190-504
Vertical deflection
Number of channels2222444
Bandwidth60 MHz100 MHz200 MHz500 MHz100 MHz200 MHz500 MHz
Rise time5.8 ns3.5 ns1.7 ns0.7 ns3.5 ns1.7 ns0.7 ns
Number of scope inputs2 input channels plus external trigger4 input channels
Channel architectureAll inputs fully insulated from each other and from ground. Inputs may be activated in any combination.
Input couplingAC or DC, with ground level indicator
Input sensitivityWith 10:1  probe, 20 mV  to 1000 V/div
With 100:1  probe, 200 mV to 10 kV/div
Direct (1:1),  2 mV  to 100 V/div
Bandwidth limiter20 MHz and 10  kHz
PolarityNormal,  Inverted, Variable
Input voltageCAT III 1000 V/CAT IV 600 V rated, see General specifications for further details
Vertical resolution8 bit
Accuracy at 4 s to 10 μs/div5 mV/div to 100 V/div, ±(1.5 % + 6 counts)
2 mV/div, ±(1.5  % + 10 counts)
Input impedance1 MΩ (± 1 %) //  15  pF (± 2.25  pF)
Horizontal
Maximum real- time sample rate (sampled simultaneously)625 MS/s
(each channel)
1.25 GS/s (each channel)2.5 GS/s (each channel)5 GS/s (single channel) or
2.5 GS/s (dual channel)
1.25 GS/s (each channel)2.5 GS/s (2ch)
1.25 GS/s (4ch)
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch)
Record lengthUp to 10,000 samples per  channel
Time base range10 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy± (0.01 % of reading + 1  pixel)
Glitch capture8 ns (10  µs/div to 2 min/div)
Display and acquisition
Display133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
Display modesAny combination of channels; average on/off; replay.
Visible screen width12  divisions horizontally in scope mode
Digital persistence modesOff, short, medium, long, infinite and envelope mode
Waveform mathematicsOne (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
Acquisition modesNormal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
SourceInput A, B or External (via meter input)Input A, B, C or  D
ModesAutomatic, Edge, Pulse Width, N-Cycle, External (190-xx2)
Connect-and- View™Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts  triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Pulse width triggering (on channel A)Pulse width qualified by time
Allows for triggeringt, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggeringTriggers on both rising and falling edges alike
N-cycle triggeringTriggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events.
ReplayManual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storageTen sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
WindowAutomatic, Hamming, Hanning or None
Automatic windowDigitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant.
Vertical scaleLinear/Logarithmic (in volts or amps)
Frequency axisFrequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compareProvides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail testingIn waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA  reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio;
Advanced power and motor drive functionsV/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters
Cursor measurements
SourceOn any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal linesVoltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical linesTime between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors.
Single vertical lineMin-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
Advanced functionsmA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors)
ZOOMRanges from full record overview to zoom in up to sample level, at any record length.
 
Meter modes
 190-062190-102190-202190-502190-104190-204190-504
Meter inputsVia 4 mm banana inputs, fully isolated from scope inputs and scope groundVia BNC scope inputs
Number of readingsOne at a time via DMM inputUp to 4 automatic scope measurements simultaneously
Maximum resolution5,000 counts± 999 counts
(frequency: 9999 counts)
Input impedance1 MΩ (± 1 %) // 14 pF (± 1.5 pF)1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
Advanced meter functionsAuto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
 The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy± (0.5 % + 6 counts)± (1.5 % + 6 counts)
V ac true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5 % + 15 counts)
60 Hz to 20 kHz± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5% + 15 counts)
60 Hz to 20 kHz± (2.5 % + 15 counts)
Voltmeter ranges500 mV, 5 V, 50 V, 500 V, 1,100 V 
Resistance
Ranges500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy± (0.6 % + 6 counts)
Other meter functions
ContinuityBeeper on < 50 Ω (± 30 Ω)
Diode testUp to 2.8 V
Current (A)A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
TemperatureWith optional accessories. Scale factors 1mV/°C or 1mV/°F
 
Recorder mode
 190-062190-102190-202190-502190-104190-204190-504
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and displayInput A, Input B,  Dual
All channels sampled simultaneously
Any combination of inputs, up to 4 channels.
All channels sampled simultaneously
Memory depth30,000 data points per channel, each holding min/max pair of information
Min/max valuesMin/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches.
Recording modesSingle sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external)Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel)
Stop-on-triggerScopeRecord mode can be stopped by an individual trigger event, or by an interruption
of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scaleTime from start, time of  day
ZoomRanges from full record overview to zoom in up to sample level
MemoryTwo multiple input ScopeRecord waveforms can be saved internally for later recall and analysis.
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range4 ms/div to 2 min/div
Recorded timespan4.8 sec to 40 hr
Time/division in ‘view all’ mode0.4 s/div to 4 h/div
Glitch capture8 ns
Sample rate125 MS/s
Resolution160 μsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and displayAny combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp.
RangesNormal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time spanUp to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings.
Recording modeContinuous recording, starting at 5 s/div with automatic time-scale compression
Measurement speedThree automatic measurements per second or more
Horizontal scaleTime from start, time of day
ZoomUp to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
MemoryTwo multiple input TrendPlot records can be saved internally for later recall and analysis.
Cursor measurements—all recorder modes
SourceAny waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical linesCursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.
 
General specifications
Input voltage range
Rated maximum floating voltageCAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410-IICAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead)
Probe input voltage VPS421CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
Maximum BNC input voltageCAT IV 300 V (maximum voltage on BNC input directly)
Maximum volt- age on meter inputCAT III 1000 V / CAT IV 600 V
(safety designed banana input connectors)
Memory save and recall
Memory loca- tions (internal)30 waveform memories plus 10 recording memories plus 9 screen copy memories
30 waveform memoriesEach memory can contain up to 2 or 4 waveforms plus corresponding setups.
10 recording memoriesEach may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements
External data storageOn PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port
ScreencopiesOn PC, using FlukeView™-2  Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
VolatilitySaving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status.
Real-time clockProvides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings.
Case
DesignRugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard.
Kensington lock supported to lock down instrument when left unattended.
Drip and dust proofIP 51  according to IEC60529
Shock and vibrationShock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2
Display size133 mm x 90 mm (5.3 in x 3.5 in) LCD
Resolution1120  pixels x 765 pixels
BrightnessUser-adjustable, up to 300  cd/m2
Mechanical data
Size265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in)
Weight (including battery)2.1 kg (4.6 lb)2.2 kg (4.8 lb)
Power
Line powerUniversal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz
Battery powerRe-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery]BP290: 10.8V, 2500 mAh
[BP291 (5000 mAh) optional]
BP291: 10.8V, 5000 mAh
Battery charge indicatorBattery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen.
Battery operat- ing time (with backlight low)Up to 3.5 using BP290  (included), up to 7 hours using BP291 (optional)Up to 7 hours using BP291 (included)
Battery charging time2½ hours using BP290; 5 hours using BP291Five hours for BP291
Battery power saving functionsAuto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time.
On-screen battery power indicator
Safety
ComplianceEN61010-1,  Pollution Degree 2;
IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V
Environmental
Operating temperatureBattery discharging: 0 °C to 40 °C (32 °F to 104 °F)
Battery charging: 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature-20  °C to 60 °C (-4 °F to 140  °F)
Humidity0 °C to 10 °C (32 °F to 50 °F): noncondensing
10 °C to 30 °C (50 °F to 86 °F): 95 % (±5 %)
30 °C to 40 °C (86 °F to 104 °F): 75 % (±5 %)
40 °C to 50 °C (104 °F to 122 °F): 45 % (±5 %)
Maximum operating altitudeCAT IV 600 V, CAT III 1000 V: up to 2000 m (6 600 feet)
CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 4000 m (13 000 feet)
Maximum storage altitude12  km (40,000 ft)
Electro-Magnetic Compatibility (EMC)IEC 61326-1: Industrial;
CISPR 11:  Group 1,  Class A;
Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment);
USA (FCC): 47 CFR 15 subpart C.
InterfacesTwo USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry.
USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2.
Probe calibration outputDedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel.
Generator Output: 1.225 Vpp / 500 Hz square wave
Warranty3 years on main instrument, 1 year on battery and accessories
Included accessories
Battery charger/ mains adapterBC190/830
Li-Ion battery packBP290 (10.8V, 2500 mAh)BP291 (10.8V, 5000 mAh)
Voltage probe sets. Each set includes ground lead, hook clip; ground spring and probe tip insulation sleeve with VPS410-II-x.2 pcs VPS421-x, ruggedized industrial-grade probes, 100:1, 150MHz with shrouded 4mm banana tip and large jaw alligator clips (one red, one blue)2 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one blue)4 pcs VPS421-x, ruggedized probes, 100:1, 150 MHz, (red, blue, grey, green)4 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one grey, one blue, one green)
Test leadsTL175 (one red, one black) with test pins
OtherLi-Ion battery (BP290 or BP291,  see above), Battery charger (BC190) with universal power cord set, Hangstrap, Handstrap (user selectable for left- or right hand use), download information for user manual and FlukeView®-2 demo package (with restricted functionality), and USB interface cable for PC connectivity. Feedthrough cable terminator, 50 Ω (one per channel, 190-50x only).
Optional configurationEach model is available as a ‘boxed’ version, described above, or with the optional SCC293 set included. SCC293 comprises: CXT293 rugged protective carrying case, full-version FlukeView PC software (activation code) and a WiFi dongle for wireless PC-connectivity using FlukeView-2 software.
Optional accessoriesSCC293, VPS101 - 1:1 voltage probe; VPS510-x - wide bandwidth compact probes; i400s–current clamp; HH290–hanging hook; CXT293–protective carrying case; TRM50–BNC Feedthrough cable terminator, 50 Ω, safety designed; EBC290–battery charging bay

 

Models: Fluke 190 Series III ScopeMeter® Test Tools

ScopeMeter 190-062-III Test Tool
Part#: 5282331
UPC#: 1 95112 02177 4
  • ScopeMeter 190-062-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 test lead set
  • VPS421 probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • Printed instructions
ScopeMeter 190-102-III Test Tool
Part#: 5282368
UPC#: 1 95112 02179 8
  • ScopeMeter 190-102-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 test lead set
  • VPS421 probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • Printed instructions
ScopeMeter 190-104-III Test Tool
Part#: 5282393
UPC#: 1 95112 02182 8
  • ScopeMeter 190-104-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS421 probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • Printed instructions
ScopeMeter 190-202-III Test Tool
Part#: 5282439
UPC#: 1 95112 02184 2
  • ScopeMeter 190-202-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 test lead set
  • VPS410-II probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • Printed instructions
ScopeMeter 190-204-III Test Tool
Part#: 5282463
UPC#: 1 95112 02186 6
  • ScopeMeter 190-204-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • Printed instructions
ScopeMeter 190-502-III Test Tool
Part#: 5282495
UPC#: 1 95112 02188 0
  • ScopeMeter 190-502-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • TL175 test lead set
  • VPS410-II probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (2 pcs)
  • Printed instructions
ScopeMeter 190-504-III Test Tool
Part#: 5282513
UPC#: 1 95112 02190 3
  • ScopeMeter 190-504-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (4 pcs)
  • Printed instructions
ScopeMeter 190-062-III/S Test Tool with kit
Part#: 5282354
UPC#: 1 95112 02178 1
  • ScopeMeter 190-062-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 testlead set
  • VPS421 probe (2x)
  • Hand strap
  • Hanging  strap
  • USB-cable
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-102-III/S Test Tool with kit
Part#: 5282379
UPC#: 1 95112 02180 4
  • ScopeMeter 190-102-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 test lead set
  • VPS421 probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-104-III/S Test Tool with kit
Part#: 5282417
UPC#: 1 95112 02183 5
  • ScopeMeter 190-104-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS421 probe (4x)
  • Hand strap
  • hanging strap
  • USB-cable
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-202-III/S Test Tool with kit
Part#: 5282442
UPC#: 1 95112 02185 9
  • ScopeMeter 190-202-III
  • BC190/830 power adapter
  • Power cord set
  • BP290 Li-ion battery pack
  • TL175 test lead set
  • VPS410-II probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-204-III/S Test Tool with kit
Part#: 5282474
UPC#: 1 95112 02187 3
  • ScopeMeter 190-204-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-502-III/S Test Tool with kit
Part#: 5282508
UPC#: 1 95112 02189 7
  • ScopeMeter 190-502-III
  • BC190/830 power adapter
  • power cord set
  • BP291 Li-ion battery pack
  • TL175 testlead set
  • VPS410-II probe (2x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (2 pcs)
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
ScopeMeter 190-504-III/S Test Tool with kit
Part#: 5282524
UPC#: 1 95112 02191 0
  • ScopeMeter 190-504-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (4 pcs)
  • CXT293 carrying case
  • DWA-131 WiFi dongle
  • FlukeView Activation instructions (paper)
  • Printed instructions
FLUKE-190-504/FPC

Fluke ScopeMeter 190-504-III Test Tool Bundled with Premium Care 1-Year Standard Plan

Part#: 5335286
UPC#: 7 54082 15529 4

Includes:

  • Premium Care 1-Year Standard Plan
  • ScopeMeter 190-504-III
  • BC190/830 power adapter
  • Power cord set
  • BP291 Li-ion battery pack
  • VPS410-II probe (4x)
  • Hand strap
  • Hanging strap
  • USB-cable
  • TRM50 cable terminator (4 pcs)
  • Printed instructions
FPC1S-SCM190-1

Premium Care 1-Year Standard Plan for Fluke ScopeMeter 190-504-III Test Tool

Part#: 5326073
UPC#: 1 95112 03830 7

Includes:

Premium Care 1-Year Standard Plan

FPC3S-SCM190-1

Premium Care 3-Year Standard Plan for Fluke ScopeMeter 190-504-III Test Tool

Part#: 5326086
UPC#: 1 95112 03831 4

Includes:

Premium Care 3-Year Standard Plan

FPC1G-SCM190-1

Premium Care 1-Year Gold Plan for Fluke ScopeMeter 190-504-III Test Tool

Part#: 5326761
UPC#: 1 95112 03839 0

Includes:

Premium Care 1-Year Gold Plan

FPC3G-SCM190-1

Premium Care 3-Year Gold Plan for Fluke ScopeMeter 190-504-III Test Tool

Part#: 5326777
UPC#: 1 95112 03840 6

Includes:

Premium Care 3-Year Gold Plan

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 21.93ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat