Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
Model#:FLUKE 3540 FC KITPart#:4948724UPC#:0 95969 86302 5
Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit is rated out of 5 by 9.
Key features
- Measures:
- Single, split, or three phase loads
- Voltage, current, and frequency
- Active power, non-active power, and power factor
- Total harmonic distortion
- Wireless data collection or internal memory sufficient for 1 week with 1 second data intervals
- Remotely monitor real-time and historical power variable data
- Visualize data with software trending, graphing, and timeboxing
- Auto-generated alarms when power variables deviate from pre-set thresholds
- Power options: Battery, power supply, or power from the measurement line
- Size: (W x H x D) 7.8 in. x 6.6 in. x 2.2 in.
- IP Rating: IP 50; IEC 60529
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
$4,140.00
Product overview: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
The Fluke 3540 FC monitors equipment for changes in key electrical variables. Current, voltage, frequency, and energy consumption fluctuate when machinery experiences excess load. Screen assets for performance or premature wear using the non-invasive 3540 FC.
- Portable device offers scalable, remote power monitoring solution
- View power measurements from a safe distance
- Wirelessly collect real-time power values
- Make data-driven decisions
See "Model" tab for kit options.
What's in the box:
- Fluke 3540 FC Three-Phase Power Monitor
- Voltage Test Lead, 3-phase + N
- (4 sets) Dolphin Clips, Black
- (3) i173x-flex1500 iFlex Current Probe, 30.5 cm (12 in)
- Set of color-coded Wire Clips
- Mains Power Cable
- (2 sets) test leads with stackable plugs, 10 cm (3.9 in)
- (2 sets) test leads with stackable plugs, 1.5 m (6.6 ft)
- DC Power Cable
- Input Connector Decal
- WiFi to USB Adapter
- Magnetic Hanging Kit
Specifications: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
General specifications | ||
Color LCD display | 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel | |
Warranty | 3540 FC and built-in power supply | 2 years (battery not included) |
Accessories | 1 year | |
Calibration cycle | 2 years | |
Dimensions (WxHxD | 3540 FC | 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in) |
Detachable power supply | 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in) | |
3540 FC with power supply attached | 19.8 cmx 16.7 x 9 cm (7.8 x 6.6 x 4.0 in) | |
Weight | 3540 FC | 1.1kg (2.5 lb) |
Power supply | ||
Tamper protection | Kensington lock |
Environmental specifications | ||
Operating temperature | 0 °C to +45 °C (+32 °F to +113 °F) | |
Storage temperature | <20 °C to +60 °C (-4 °C to +140 °F), with battery: -20 °C to +50 °C (-4 °F to +122 °F) | |
Operating humidity | <10 °C (<50 °F) non condensing | |
+10 °C to +30 °C (+50 °F to +86 °F) ≤95 % | ||
+30 °C to +40 °C (+86 °F to +104 °F) ≤75 % | ||
+40 °C to +45 °C (+104 °F to +113 °F) ≤45 % | ||
Operating altitude | 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) | |
Storage altitude | 12,000 m (39,000 ft) | |
IP Rating | IEC 60529:IP50, in connected condition with protection caps in place | |
Vibration | MIL-T-28800E, Type 3, Class III, Style B | |
Safety | ||
IEC 61010-1 | IEC mains input | Overvoltage Category II, Pollution Degree 2 |
Voltage terminals | Overvoltage Category IV, Pollution Degree 2 | |
Electromagnetic compatibility (EMC) | ||
International | IEC 61326-1: Industrial | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Wireless radio with adapter | ||
Frequency range | 2412 MHz to 2462 MHz | |
Output power | <100 mW |
Electrical specifications | ||
Single and three-phase topologies | ||
Wiring configurations | 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies) | |
Voltage inputs | ||
Number of inputs | 4 (3 phases and neutral) | |
Maximum input voltage | 1000 Vrms (1700 Vpk) phase to neutral | |
Input impedance | 10 MΩ each phase to neutral | |
Bandwidth | 42.5 Hz to 3.5 kHz | |
Scaling | 1:1, variable | |
Current inputs | ||
Number of inputs | 3, mode selected automatically for attached sensor | |
Current sensor output voltage | Clamp | 500 mVrms / 50 mVrms; CF 2.8 |
Rogowski coil | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range | |
Bandwidth (-3 dB) | 42.5 Hz to 3.5 kHz | |
Scaling | 1:1 and variable | |
Data acquisition | ||
Resolution | 16-bit synchronous sampling | |
Sampling frequency | 10.24 kHz at 50/60Hz, synchronized to mains frequency | |
Input signal frequency | Mains 50/60 Hz (42.5 to 69 Hz) | |
Data storage | Internal flash memory (not user replaceable) | |
Memory size | Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements. | |
Measured parameters | Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF | |
Averaging interval | 1 s | |
Total harmonic distortion | THD for voltage and current is calculated on 25 harmonics | |
Calculated min/max values times | ||
Voltage | Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ) | |
Current | Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz) | |
Power | 200 ms | |
Interfaces | ||
USB-A | Firmware updates, max. supply current: 120 mA | |
WiFi | ||
Supported modes | Direct connection and connection to infrastructure | |
Security | WPA2-AES with pre-shared key | |
Power supply | ||
Voltage range | Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input | |
Mains power | Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input | |
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) | |
Standby power | <0.3 W only when powered using IEC 60320 input | |
Efficiency | ≥68.2 % (in accordance with energy efficiency regulations) | |
Mains frequency | 50/60 Hz ±15 % | |
Battery power | Li-ion 3.7 V, 9.25 Wh, customer-replaceable | |
On-battery runtime | Up to 4 hr (up to 5.5 hr in energy saving mode) | |
Charging time | <6 hr |
Models: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
FLUKE 3540 FC KIT
Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
UPC#: 0 95969 86302 5
Includes:
- 1 Fluke 3540 FC Three-Phase Power Monitor
- Voltage Test Lead, 3-phase + N
- 4x Dolphin Clips, Black
- 3x i173x-flex1500 iFlex Current Probe, 30.5 cm (12 in)
- Set of color-coded Wire Clips
- Mains Power Cable
- Set of 2 test leads with stackable plugs, 10 cm (3.9 in)
- Set of 2 test leads with stackable plugs, 1.5 m (6.6 ft)
- DC Power Cable
- Input Connector Decal (see Figure 5)
- WiFi to USB Adapter
- Magnet Hanger Kit
Purchase comes with Fluke Connect Condition Monitoring software.
Rated 1 out of 5 by JoeW from Frustrating to set up, difficult to access data Poor instructions. Setting this device up to log is an exercise in frustration. Tech support revealed that to log phase to phase voltage you must set it up as Delta even if system is Wye?! Getting data off of it takes forever. Logging sessions get corrupted in the transfer process. This device is very sub-par.
Date published: 2024-09-11
Rated 1 out of 5 by Fowler from I'm glad I read the reviews. I think I will stick to Fluke for DMMs and not much else after checking out this power analyzer product and reading the reviews about software-as-a-service making it completely useless. I will be purchasing the other vendor's product.
Date published: 2024-07-21
Rated 1 out of 5 by Zach1111 from Predatory practices It’s sad to see that you spend thousands of dollars only to find you can’t get your data unless you pay for a subscription so you never truly own or can see your measurements unless you pay forever
Date published: 2024-06-27
Rated 1 out of 5 by dany from really bad I recently purchased the Fluke 3540 FC Power Monitor with high hopes for its performance and capabilities. However, my experience with this product has been nothing short of disappointing.
Despite my efforts to generate reports using downloaded sessions, I encountered numerous issues. The software provided did not allow for proper analysis, and attempts to connect via USB proved futile, resulting in wasted time and effort.
This power monitor has left me with a very negative impression. As a customer, I expected a more seamless and user-friendly experience, especially from a reputable brand like Fluke.
I urge potential buyers to approach this product with caution and to thoroughly research alternative options before making a purchase. Fluke should address these issues promptly to maintain trust and satisfaction among its customer base.
Overall, my experience with the Fluke 3540 FC Power Monitor has been deeply unsatisfactory, and I cannot recommend it based on my usage
Date published: 2024-03-28
Rated 1 out of 5 by JPac from Don't waste your $$ Unless you use this daily and can account for the subscription cost through revenue from clients then don't waste your money. Totally useless without a subscription.
Date published: 2023-03-30
Rated 1 out of 5 by NumberSix from No way to connect with this thing via USB Ridiculous that I cant jsut plug this into my laptop and download the data. I am forced to use Fluke Connect, which requires a subscription.
Date published: 2023-03-22
Rated 1 out of 5 by User123 from Tool is completely useless What is holding this back is the app. You need to use the app even to set up the local logging.
You need a subscription to even use the meter in local mode. The mobile device needs to be connected to the internet and to the device at the same time.
Date published: 2022-10-24
Rated 1 out of 5 by electro from Very Disappointed This is a very expensive tool that requires a subscription for use. There is no way to pull the data off of the tool unless you buy the subscription. This is now a very expensive paperweight. Remember you will never own this instrument. This is a rental with a 3700.00 down payment with a 1200.00 a year lease.
Date published: 2022-10-19
Manuals + resources: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
- 3540 FC | Case Study | B3 Electric saves time, improves safety, builds reputation with Fluke Power Monitors
- 3540 FC | Case Study | Fluke power monitoring helps UPS manager confidently relay data to TV clients
- 3540 FC | Case Study | Marquis Medical wins with 3-phase power monitor
- 3540 FC | Case Study | OptoTech achieves cost savings with power monitor
- Condition Monitoring | Case study | Parts Manufacturer Leverages Fluke Sensors to Launch IIoT-powered Asset Monitoring
- FRS CASE STUDY: 3540 FC Crestline Sanitation Case Study