Fluke Calibration P3000 Pneumatic Deadweight Testers
Key features
- 0.015% of reading accuracy standard (0.008% optional)
- 1-30 inHg vacuum (0.03-1 bar vacuum)
- 3-500 psi (0.2-35 bar) pressure
- inH2O and mbar ranges available
- Series 3 non-magnetic stainless steel weights
- Units can be trimmed to local gravity FOC
Product overview: Fluke Calibration P3000 Pneumatic Deadweight Testers
This versatile instrument provides calibrations from 1-30 inHg vacuum (0.03-1 bar) and 3-500 psi (0.2-35 bar) in one extremely accurate yet easy to use primary standard. A selector valve converts the unit from pressure to vacuum mode without the need to exchange pistons. Units are manufactured to the highest standards with certified accuracies traceable to International Standards Laboratories such as the National Institute of Standards and Technology (NIST). These piston/cylinder type pneumatic standards provide excellent stability, repeatability and accuracy. An optional built-in hand pump can be added for both pressure and vacuum generation.
Specifications: Fluke Calibration P3000 Pneumatic Deadweight Testers
Accuracy | ||
Accuracy1 | ±0.015% of reading (±0.008% optional) | |
1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range. | ||
Mass and PCU Materials of Construction | ||
Standard weight material | Series 3 non-magnetic austenitic stainless steel | |
Weight density | 7.8 g/cm³ | |
Optional fractional weights | Solution heat treated aluminum | |
Weight density | 2.7 g/cm³ | |
Models P3011, P3012, P3013, P3022, P3023, P3025 (V) | Piston material | Ceramic |
Cylinder material | Martensitic steel | |
Coefficient of expansion | 11 ppm/°C | |
Models P3014, P3015, P3025 (P) P3031, P3032 (P & V) | Piston material | Tungsten carbide |
Cylinder material | Martensitic steel | |
Coefficient of expansion | 16.5 ppm/°C | |
Model P3016 | Piston material | Tungsten carbide |
Cylinder Material | Tungsten carbide | |
Coefficient of Expansion | 11 ppm/°C | |
General | ||
Test port adaptors | 1/8, 1/4, 3/8 and ½ NPT or BSP | |
Instrument weight | 24 lbs | |
Instrument size (W x D x H) | 17.5 x 12 x 8.5 | |
Mass set weight (typical) | 65 lbs | |
Minimum Standard Weight Increments | ||
P3012, P3022 Pressure | 1 inH2O, (5 mbar) | |
P3013, P3023 Pressure | 2 inH2O, (10 mbar) | |
P3014, P3015, P3025 Pressure | 1 psi, (0.1 bar) | |
P3016, P3031, P3032 | 1 psi, (0.1 bar) | |
P3011, P3022, P3023, P3025 Vacuum | 0.2 inHg (10 mbar) | |
Optional Fractional Weights | ||
P3014, P3015, P3025 Pressure | 0.1 psi (0.01 bar) | |
Built-in Hand Pumps | ||
Pressure mode | Max pressure 300 psi (20 bar) | |
Vacuum mode | To 90% vacuum | |
Operating Fluid for Liquid Lubricated Models | ||
55-655 | Mineral oil (standard) | |
Krytox | For oxygen-safe applications (optional) | |
Options | ||
PressCal Software | Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments. | |
Krytox | As operating fluid for liquid lubricated gas operated models. |
Models: Fluke Calibration P3000 Pneumatic Deadweight Testers
Pressure Range 1 to 70 bar
UPC#: 0 95969 63784 8
Pressure Range 1 to 70 kgf/cm
UPC#: 0 95969 63785 5
Pressure Range 100 to 7,000 kPa
UPC#: 0 95969 63787 9
Pressure Range 0.1 to 7 Mpa
UPC#: 0 95969 63788 6
Pressure Range 10 to 1,000 psi
UPC#: 0 95969 63786 2
Pressure Range 1 to 140 bar
UPC#: 0 95969 63789 3
Pressure Range 1 to 140 kgf/cm
UPC#: 0 95969 63790 9
Pressure Range 100 to 14,000 kPa
UPC#: 0 95969 63792 3
Pressure Range 0.1 to 14 Mpa
UPC#: 0 95969 63793 0
Pressure Range 10 to 2,000 psi
UPC#: 0 95969 63791 6
Vacuum range 1 to 30 inHg
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Vacuum operated – single PCU
- Built-in pump optional
Vacuum range 3 to 100 kPa
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Vacuum operated – single PCU
- Built-in pump optional
Vacuum range 30 to 1,000 mbar
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Vacuum operated – single PCU
- Built-in pump optional
Vacuum range 30 to 760 mmHg
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Vacuum operated – single PCU
- Built-in pump optional
Pressure range 5 to 400 inH20
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 1.5 to 1,000 kPa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 15 to 1,000 mbar
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 12 to 800 inH2O
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 3 to 200 kPa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 30 to 2,000 mbar
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 0.2 to 10 bar
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 0.2 to 10 kgf/cm²
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 20 to 1,000 kPa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 0.02 to 1 Mpa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 3 to 150 psi
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
Pressure range 0.2 to 35 bar
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
- Built-in pump optional
Pressure range 0.2 to 35 kgf/cm²
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
- Built-in pump optional
Pressure range 20 to 3,500 kPa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
- Built-in pump optional
Pressure range 0.02 to 3.5 Mpa
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
- Built-in pump optional
Pressure range 3 to 500 psi
Includes:
- P3000 Series Single Pressure Model
- Air operated – single PCU
- Built-in pump optional
Pressure range 5 to 400 inH2O
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 1 to 30 inHg
- Built-in pump optional
Pressure range 1.5 to 100 kPa
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 3 to 100 kPa
- Built-in pump optional
Pressure range 15 to 1,000 mbar
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 30 to 1,000 mbar
- Built-in pump optional
Pressure range 12 to 800 inH2O
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 1 to 30 inHg
- Built-in pump optional
Pressure range 3 to 200 kPa
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 3 to 100 kPa
- Built-in pump optional
Pressure range 30 to 2,000 mbar
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 30 to 1,000 mbar
- Built-in pump optional
Pressure range 0.2 to 35 bar
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 30 to 1,000 mbar
- Built-in pump optional
Pressure range 0.2 to 35 kgf/cm²
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 30 to 760 mmHg
- Built-in pump optional
Pressure range 20 to 3,500 kPa
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 3 to 100 kPa
- Built-in pump optional
Pressure range 0.02 to 3.5 Mpa
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 3 to 100 kPa
- Built-in pump optional
Pressure range 3 to 500 psi
Includes:
- P3000 Series Vacuum and Dual Vacuum/Pressure Model
- Air operated - dual PCU
- Vacuum Range 1 to 30 inHg