RPM4-AD Reference Pressure Monitor
Model#:RPM4-AD A160Ka/A160Ka
Key features
- Fixed wing and rotary wing range versions
- True Pt, Ps, Qc operation
- Transfer standard level measurement uncertainty
- Automated rate measurement with user specified sample time
- Automated leak check function
Product overview: RPM4-AD Reference Pressure Monitor
RPM4-AD Air data version
RPM4-AD is a specific configuration of the RPM4 reference pressure monitor that measures and displays altitude (ft, m), airspeed units (kts, mph, km/h, Mach) and in conventional pressure units.<
Specifications: RPM4-AD Reference Pressure Monitor
RPM4-AD General Specifications | |||
Power Requirements | 85 to 264 VAC, 50/60 Hz, 25 VA max consumption and 12VDC, 1.2 A | ||
Operating Temperature Range | 15 to 35 °C | ||
Ventilation | To prevent product overheating, provide proper ventilation. Allow 10 cm (4 in.) clearance from rear panel cooling fan. | ||
Storage Temperature Range | - 20 to 70 °C | ||
Vibration | Meets MIL-T-28800D | ||
Weight | 5 kg (11 lb) | ||
Dimensions | 10 cm H x 22.7 cm W x 24 cm D (3.9 in. x 9.3 in. x 9.5 in.) | ||
Microprocessors | Motorola 68302, 16 MHz | ||
Communication Ports | RS232 (COM1, COM2), IEEE-488.2 | ||
Fuses | 1 A, 250 VAC fuse, 5 x 20 mm, time lag type fuse Internal power supply fuse not replaceable by operator: 2.5A, 250 VAC | ||
Pressure Ranges | Lo Q-RPT | Hi Q-RPT | Qc (sea level) |
A160K/A160K | 160 kPa abs (23 psi) | 160 kPa abs (23 psi) | 60 kPa (8.7 psi) |
A160K/A350K | 160 kPa abs (23 psi) | 350 kPa abs (51 psi) | 250 kPa (36 psi) |
Altitude Range | |||
A160K/A160K | - 4 000 to 20 000 m (- 13 000 to 66 000 ft) | ||
A160K/A350K | - 4 000 to 30 000 m (- 13 000 to 100 000 ft) | ||
Airspeed Range (sea level) | |||
A160K/A160K | 0 to 1020 km/hr (550 kts) | ||
A160K/A350K | 0 to 2040 km/hr (1100 kts) | ||
Operating Medium | Clean, dry, non-corrosive gas | ||
Pressure Connections | |||
Ps , Pt | AN-4 (37º flare) male | ||
VENT, ATM | 10-32 UNF | ||
Self Defense System (SDS™) | Included. Isolates Q-RPTs from Ps and Pt test ports and vents Q-RPTs to atmosphere. | ||
Pressure Limits | A160K Q-RPT | A350K Q-RPT | |
Maximum working pressure | 160 kPa abs (23 psi) | 350 kPa abs (51 psi) | |
Maximum pressure without damage | 200 kPa abs (29 ipsi) | 370 kPa abs (54 psi) | |
Maximum SDS protection | 10 MPa (1500 psi) | ||
CE Mark | Available, must be specified |
Models: RPM4-AD Reference Pressure Monitor
RPM4-AD A160Ka/A160Ka
Reference Pressure Monitor, Air Data Version (rotary wing)
RPM4-AD A350Ka/A160Ka
Reference Pressure Monitor, Air Data Version (fixed wing)