1586A Super-DAQ Precision Temperature Scanner Resource Center

Save time and money by using a 1586A Super-DAQ and a Fluke Calibration dry-well, fluid bath, or furnace to automate the calibration of up to 40 temperature sensors—simultaneously, without requiring a PC or software. With accuracies as good as ± 0.005 °C, the 1586A can read RTDs thermocouples, and thermistors at up to 10 channels per second.

Calibrating multiple sensors simultaneously saves time. Automating the process lets you set up a test and walk away to do other work, enabling you to become much more productive.

This resource center page presents an application note and video to show you how easy it is to automate temperature sensor calibration. 

To learn more about the 1586A Super-DAQ, visit the product page:
1586A Super-DAQ Precision Temperature Scanner
 

If you would like to get a quote on a new 1586A Super-DAQ, you can do that here:

Request a quote

Automating temperature sensor calibration with the 1586A Super-DAQ 

Application Note

Take your temperature calibration productivity to the next level in just 7 easy-to-follow steps. This application note explains how to use a 1586A Super-DAQ and a Fluke Calibration dry-well, fluid bath, or furnace to perform automated sensor calibrations--without a PC and software.

Step-by-step video guide

Watch this step-by-step video guide to learn how easily you can automate sensor calibration with a 1586A Super-DAQ and a Fluke Calibration dry-well, fluid bath, or furnace.

If you find "Automating temperature sensor calibration" useful, you might also enjoy these additional videos. 

1586A introduction video

1586A Super-DAQ Precision Temperature Scanner

If you are just starting to learn about the 1586A Super-DAQ, this video will give you a good high-level introduction to its features and benefits.

1586A Super-DAQ demo video series

1586A Super-DAQ Demo Video Series

These  brief videos show what the 1586A Super-DAQ can do for you. 

Video 1: Introduction and setup  This video includes an overview of the 1586A front panel and shows how easy it is to set up the instrument and then use it to read a PRT

Video 2: Configuring input channels 
This video demonstrates how to configure input channels on the 1586A Super-DAQ using the High-Capacity Module or the DAQ-STAQ Multiplexer.

Video 3: Running a scan, recording and saving data 
This video demonstrates running a scan, recording and saving data with the 1586A.

 Video 4: Viewing, graphing, and monitoring scan data 

Once you have recorded and saved scanned data, watch this video to see how to view, graph, and monitor it

Video 5: Automating a test using a dry-well 

This video provides an overview of how to automate a test using the 1586A with a dry-well calibrator.