Thermocouple Calibrators

Whether you're simulating thermocouples or calibrating thermocouples directly through comparison methods, Fluke offers the most comprehensive selection of quality thermocouple calibrators on the market, including thermocouple simulators, handheld multifunction calibrators, temperature sources such as dry-block calibrators and liquid baths, thermocouple reference Standards, and thermocouple readouts.

Thermocouple calibration product catagories include:

  • Handheld thermocouple calibrators and simulators
  • Comparison calibration instruments

Speak with an expert

 

Handheld Thermocouple Calibrators and Simulators


These handheld products are used for calibration of thermocouple indicators and thermocouple measurement devices such as temperature transmitters.

ModelRangeThermocouple TypeDescription/Features
754 Documenting Process Calibrator-HART
 
-250 to 2500 °CE, N, J, K, T, B, R, S, C, L, U, BP, XKDocumenting calibrator with HART, TC and RTD temperature calibrator, with loop power, source/measure TC and measures mA
7526A Precision Process Calibrator–250 °C to 1767 °CB, C, E, J, K, L, N, R, S, T, U, XK, BPOffers the best balance of economy and accuracy for benchtop calibration of temperature and pressure process instrumentation
726 Precision Multifunction Calibrator-200 to 1800 °CJ, K, T, E, L, N, U, C, BP, XK, B, R, SMultifunction calibrator (twice as accurate as 725)
725 Multifunction Process Calibrator-200 to 1800 °CJ, K, T, E, R, S, B, L, U, NMultifunction calibrator, TC and RTD temperature calibrator, with loop power, source/measure TC and measures mA
724 Temperature Calibrator–200 to 1800 °CJ, K, T, E, R, S, B, L, UTC and RTD temperature calibrator, with loop power, source/measure TC and measures mA
714B Thermocouple Calibrator-250 to 1410 °CE, N, J, K, T, B, R, S, C, L, U, BP, XK, G, D, P, MThermocouple (TC) temperature calibrator, source/measure TC and measures mA

Comparison Calibration Instruments


Calibration of a thermocouple by comparison methods requires:

  • Reference thermometer
  • Thermometer readout
  • Stable and uniform temperature source

Fluke offers a wide range of products to fit your temperature range, accuracy, and budget requirements.

Reference Thermometers

ModelRangeAccuracyDescription/Features
5649/5650 Type R and Type S Thermocouple Standards0 °C to 1450 °Cgreater of ±0.6°C or ±0.1% of readingEight models to fit any ype R or S thermocouple application
5624 Platinum Resistance Thermometer to 1000 °C0 °C to 1000 °C

± 0.006 °C at 0 °C

± 0.031 °C at 660 °C

± 0.041 °C at 961 °C

World’s finest high-temperature secondary PRT
5628 High-Temperature Secondary Standard–200 °C to 661 °C

± 0.006 °C at –200 °C

± 0.006 °C at 0 °C

± 0.015 °C at 420 °C

± 0.022 °C at 661 °C

Fills the gap between affordable, but temperature-limited secondary PRTs and more expensive, highly accurate SPRTs
5609 Secondary Reference PRT–200 °C to 670 °C

± 0.007 °C at –200 °C

± 0.008 °C at 0 °C

± 0.020 °C at 420 °C

± 0.027 °C at 660 °C

Very stable thermometer

 

 

Thermometer Readouts

ModelRangeAccuracyDescription
1586A Super-DAQ Precision Temperature Scanner-15 mV to 100 mV0.004 % + 4 µVMost accurate and flexible temperature data acquisition system on the market
1560 Black Stack Thermometer Readout-10 to 100 mV± 0.002 mVAccurate, expandable and configurable readout
1529 Chub-E4 Standards Thermometer-10 mV to 100 mV± 0.005 mVLab-quality accuracy on four channels
1523/1524 Handheld Reference Thermometers

0 Ω to 400 Ω ± (0.004 % + 0.002 Ω)

200 Ω to 50 kΩ± (0.01 % + 0.5 Ω)

50 kΩ to 500 kΩ± (0.03 %)

Measure, graph and record three sensor types with one tool

Thermocouple Calibration Furnaces

ModelRangeStabilityDescription/Features
9118A Thermocouple Calibration Furnace300 °C to 1200 °C

± 0.2 °C (without block),

± 0.1 °C (with block)

Horizontal thermocouple furnace. Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples.
9150 Portable Thermocouple Furnace

150 °C to 1200 °C

302 °F to 2192 °F

±0.5 °C

Benchtop thermocouple furnace.

Interchangeable insert sleeves.

Fast heating and cooling.

Dry-Block Calibrators

ModelRangeAccuracyDescription/Features
9142 Field Metrology Well–25 °C to 150 °C± 0.2 °C

Light-weight portable and fast

Reads and documents °C, mV, W, and 4-20 mA

24 volt loop power

Includes accredited certificate of calibration

9143 Field Metrology Well33 °C to 350 °C± 0.2 °C
9144 Field Metrology Well50 °C to 660 °C

± 0.35 °C at 50 °C

± 0.35 °C at 420 °C

± 0.5 °C at 660 °C

9190A Field Metrology Well–95 °C to 140 °CAccuracy: ± 0.2 °CHorizontal thermocouple furnace.   Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples.

Liquid Baths

 

ModelRangeStabilityDepthDescription/Features
6109A Portable Calibration Bath35 °C to 250 °C0.015 °C400 mm (15.7 in)Four times more calibration throughput and twice the accuracy of Micro-Baths and dry-block calibrators
7109A Portable Calibration Bath–25 °C to 140 °C (–15 °C cover off)0.01 °C400 mm (15.7 in)Four times more calibration throughput and twice the accuracy of Micro-Baths and dry-block calibrators
6330 Compact Temperature Calibration Bath35 °C to 300 °C

±0.005 °C at 100 °C

±0.015 °C at 300 °C

234 mm

(9.25 in)

Small benchtop footprint.

Optional cart includes storage space.

High temperature bath

7320 Temperature Calibration Bath–20 °C to 150 °C

±0.005 °C at –20 °C

±0.005 °C at 25 °C

234 mm

(9.25 in)

Small 9.2-liter (2.4-gallon) tank.

Uniformity ±0.005 °C.

7340 Compact Temperature Calibration Bath–40 °C to 150 °C

±0.005 °C at –40 °C

±0.005 °C at 25 °C

234 mm

(9.25 in)

Low temperature calibrations.

Metrology-level performance.

7380 Compact Temperature Calibration Bath–80 °C to 100 °C

±0.006 °C at –80 °C

±0.010 °C at 0 °C

178 mm

(7 in)

Achieves –80 °C in less than 130 minutes.

Quiet operation.

6331 Deep-Well Compact Bath40 °C to 300 °C±0.007 °C at 100 °C ±0.015 °C at 300 °C457 mm (18 in )18 in of depth with just 16 liters of fluid. RS-232 included.
7321 Deep-Well Compact Bath–20 °C to 150 °C ±0.005 °C at –20 °C ±0.005 °C at 25 °C457 mm (18 in)Perfect for LIG thermometers with optional kit. Quiet operation. 
7341 Deep-Well Compact Bath–45 °C to 150 °C ±0.005 °C at –40 °C ±0.005 °C at 25 °C 457 mm (18 in)Fast temperature changes. Access opening accommodates many thermometers. 
7381 Deep-Well Compact Bath–80 °C to 110 °C ±0.006 °C at –80 °C ±0.005 °C at 0 °C 457 mm (18 in)Stability of ±0.006 °C or better over full range. Compatible with MET/TEMP II software. Low temperature bath

Calibration Bath Accessories

Bath AccessoriesStands, rods, and clamps to suspend and support your probes and thermometers
Bath FluidsSilicone oils, salt, and cold fluids in convenient, small quantities. 