Fluke 802EN Vibration Meter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 119.01ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 802
  • Fluke 802
  • Fluke 802
  • Fluke 802

Key features

  • Three test modes to meet complex test environment in industrial field
  • High repeatability to ensure accuracy of continuous testing
  • One-button measurement to get assessment result in 6 seconds
  • 99 sets of data storage, review in real-time

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
S$1590.00
9% GST Included
Genuine Fluke Product
Free shipping for cart size over $50
Parcel will be shipped out within 3 working days. If there are delays due to unforeseen circumstances, we will keep you updated.

Product overview: Fluke 802EN Vibration Meter

Fluke 802EN Vibration Meter

One-button vibration assessment of mechanical equipment

Specifications: Fluke 802EN Vibration Meter

Internal Piezoelectric Accelerometer
Sensitivity (typical)10.00 mV / m/s² ± 5% (1 g = 9.8 m/s²)
Measurement
AccelerationRange0.1 m/s² to 199.9 m/s² peak (rms √2)
Resolution0.1 m/s²
Accuracy± (5 % + 2 dgt) (LO: 10 Hz to 1 kHz)
± (10 % + 5 dgt) (HI: 1 kHz to 10 kHz)
VelocityRange0.1 mm/s to 199.9 mm/s rms
Resolution0.1 mm/s
Accuracy± (5% + 2 dgt) (10 Hz to 1 kHz)
DisplacementRange0.001 mm to 1.999 mm peak-peak (rms 2√2)
Resolution0.001 mm
Accuracy± (5 % +2 dgt) (10 Hz to 1 kHz)
Piezoelectrical Accelerometer
Typical frequency response10 Hz to 15 kHz
Amplitude Units
Accelerationg, m/s²
Velocitymm/s
Displacementmm
External Piezoelectrical Accelerometer
DC bias voltage6 V dc to 7 V dc
DC bias current3.5 mA
Note: Other specifications are the same as those of the internal piezoelectric accelerometers
Battery2 AAA, IEC LR03
Battery life25 hrs for measurement
Dimensions (L x W x H)24.1 x 7.1 x 5.8 cm
Weight220 g
Audio portStereo audio output jack (3.5 mm Audio Plug)
External sensor portM12 plug
Environment
Operating temperature-10 °C to 50 °C
Storage temperature-30 °C to 60 °C
Operating humidity30% to 90% RH (non-condensing)
Operating altitude2,000 m
Storage altitude12,000 m
Ingress ProtectionIP 40
Vibration limit500.0 m/s² peak
Drop test1 m
Electromagnetic Compatibility (EMC)International IEC 61326-1: Portable, Industrial Electromagnetic Environment; CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.

Models: Fluke 802EN Vibration Meter

FLUKE-802EN

Buy it
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 126.41ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.