Key features

  • The body weighs only 154g and is 16mm thick, which is light and portable and can be put into a pocket
  • The slim and thin jaw of only 10mm can easily fit into tightly packed wires
  • 600A AC/DC range (D model), 0.01A high resolution
  • Tests voltage, resistance and continuity
  • Tests current frequency and voltage frequency
  • Tests capacitance and diodes
  • Backlight

Product overview: Fluke 301D AC/DC Clamp Meter

The Fluke 301D Series AC/DC Clamp Meter is designed with a lightweight and compact body, which allows you to carry it around in your pocket. The slim and thin jaw can easily fit into tightly packed wires. The Fluke 301D test current, voltage, resistance, continuity, frequency (voltage and current), capacitance, and diode, etc.. You can handle multiple test needs with just one tool. With the AC/DC function, it can be applied to more application scenarios requiring DC testing, such as new energy of PV and wind power, new energy vehicles, communications, data centers, etc..

Specifications: Fluke 301D AC/DC Clamp Meter

AC Current (45 to 400 Hz)Range60.00 A600.0 A
Resolution0.01 A0.1 A
Accuracy2% + 102% + 5
DC CurrentRange60.00 A600.0 A
Resolution0.01 A0.1 A
Accuracy2% + 102% + 5
AC Voltage (45 to 400 Hz)Range600.0 V
Resolution0.1 V
Accuracy1.5% + 5
DC VoltageRange600.0 V
Resolution0.1 V
Accuracy1% + 5
ResistanceRange600.0 Ω
6.000 kΩ
60.00 kΩ
Accuracy1% + 5
Voltage FrequencyRange9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Accuracy0.1% + 3
Current FrequencyRange45.0-400.0 Hz
Accuracy0.1% + 3
CapacitanceRange9.999 uF99.99 uF 999.9 uF
Accuracy2% + 55% + 5
DiodeRange3.000 V
Accuracy10%
T-rms Value-
Continuity
Hold
Backlight
Safety ratingCAT III 300 V
Weight154 g
Size190 mm x 52 mm x 16 mm
Jaw Opening34 mm
Clamp Arm Size10 mm X 10 mm
Battery(2) AAA batteries
Warranty1 year

General Specifications

Maximum Voltage between any Terminal and Earth Ground300 V
Maximum Differential Voltage between V/Ω and COM Terminals600 V
Display (LCD)6000 counts, updates 3 times per second
Battery Type2 AAA, IEC LR03
Battery Life500 hours minimum
Auto Power Off Time20 minutes
TemperatureOperating: -10 °C to 50 °C;
Storage: -30 °C to 60 °C
Relative HumidityOperating Humidity: Non condensing (<10°C); ≤ 90 % RH at 10 °C to 30 °C; ≤ 75 % RH at 30 °C to 40 °C; ≤ 45 % RH at 40 °C to 50 °C;
AltitudeOperating: 2000 m; Storage: 12000 m
Temperature Coefficient0.1 x (specified accuracy) /°C (<18 °C or >28 °C)
Dimensions (H x W x L)190 mm x 52 mm x 16 mm
Weight132 g (301D/E 154 g)
Jaw Opening34 mm
Ingress Protection RatingIP30
SafetyIEC 61010--1, IEC61010-2-032 CAT III 300 V, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326--1: Portable