Fluke i310s Current Probe
Key features
- Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
- Measuring Ranges: ±45 A and 450 A dc
- Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
- Resolution: ±50 mA (40 A) to ±100 mA (400 A)
- Load Impedance: > 10 k Ohms and £ 100 pF
- Frequency Range (small signal): DC to 20 kHz (- 3 dB)
- Phase Shift below 1 kHz, < 2 degrees
- Temperature Coefficient: ±0.1% of reading / °C
- Power Supply: 9 V Alkaline
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
S$950.00
Product overview: Fluke i310s Current Probe
The i310s current probe is based on Hall Effect technology for use in measurement of both DC and AC current. The i310s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.
Specifications: Fluke i310s Current Probe
Electrical Characteristics | ||
Current ranges | 30 A and 300 A AC rms or ±45 A and 450 A DC | |
Measuring ranges | ±45 A and 450 A DC | |
AC rms or DC | ±45 A and 450 A | |
Inrush current | 600A AC rms MAX | |
Output sensitivity | 10 mV/A (30 A) | |
1 mV/A (300 A) | ||
Accuracy (at +23°C) | (30 A range) | ±1% of reading ±50 mA |
(300 A range) | ±1% of reading ±300 mA | |
Bandwidth to meet accuracy specification | 1 kHz | |
Phase shift below 1 kHz | < 2 degrees | |
Resolution | ±50 mA (30 A) | |
±100 mA (300 A) | ||
Load impedance | > 10 k Ohms and ≤100 pF | |
Conductor position sensitivity | ±1.5% relative to centre reading | |
Frequency range (small signal) | DC to 20 kHz (-3 dB) | |
Phase shift below 1 kHz | < 2° | |
Temperature coefficient | ±0.1% of reading / °C | |
Power supply | 9 V Alkaline, MN1604/PP3 | |
Battery life | 30 Hours, low battery indicator | |
Working voltage (see Safety Standards section) | 300 V AC rms or DC | |
General Characteristics | ||
Maximum conductor size | 19 mm diameter | |
Output connection | Safety BNC connector | |
Supplied with safety 4mm adaptor | ||
Output zero | Manual adjust via thumbwheel | |
Cable length | 2 metres | |
Operating temperature range | -10 to +50°C | |
Storage temperature range (with battery removed) | -20 to +85°C | |
Operating humidity | 15% to 85% (non-condensing) | |
Weight | 250 g | |
Safety | IEC 61010-1, Pollution Degree 2 | |
IEC 61010-2- 032: CAT III 300V | ||
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz. | ||
EMC Compatibility | IEC 61326-1: Portable Electromagnetic Environment |
Models: Fluke i310s Current Probe
Fluke-i310s