- Precise laser technology for more accurate and repeatable measurements
- Temperature accuracy of up to ± 1℃ or ± 1% of reading whichever is greater with 20:1 distance to spot ratio
- Flashlight and large, easy-to-read backlit LCD display for easy viewing even in dark environment
- IP54 rated for extra protection against airborne contaminants
- Get your tool to work when you can't - set time and desired interval between measurements and Auto Capture will capture spot temperatures unattended
- 99 data point logging
- 30 hour battery life so your tool can perform as long as you need it to
- Displays the minimum, maximum or average temperature, or the difference between two measurements
- Hi and Lo alarms for rapid display of measurements outside set limits
- Small and lightweight design fits easily into your tool box
- Powered by one (1) AA alkaline battery
Product overview: Fluke 64 MAX IR Thermometer
The Fluke 64 MAX thermometer has the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 meter drop, you can count on this lightweight, compact infrared thermometer to work when you need it to work – even in the harshest environments and when you're not able to be there.
Useful resources and rugged tools for Solar professionals
Helpful hints
Infrared thermometers: electrical, industrial, and HVAC applications
Specifications: Fluke 64 MAX IR Thermometer
Key features | 64 MAX |
Temperature Range | -30 °C to 600 °C (-22 °F to 1112 °F) |
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C | ± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C |
Optical Resolution | 20 : 1 (calculated at 90 % energy) |
Response Time (95 %) | < 500 ms (95% of reading) |
Spectral Response | 8 to 14 microns |
Emissivity | 0.10 to 1.00 |
Display Resolution | 0.1 °C (0.2 °F) |
Repeatability (% of reading) | ± 0.5% of reading or ± 0.5 °C (whichever is greater) |
Auto Capture | Set time and interval to capture up to 99 measurements |
Internal memory | 99 data point logging capability |
Flashlight | Yes |
Power | 1 AA battery |
Battery life | 30 hours with laser and backlight on |
Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F) (without battery) |
Operating Humidity | Non- condensing @ ≤ 10 °C (50 °F) ≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F) ≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F) ≤ 45 % RH @ 40 °C 104 °F to 50 °C (122 °F) |
Operating Altitude | 2,000 meters above mean sea level |
Optical Resolution | 12,000 meters above mean sea level |
Drop test | 3 meters |
Implement Standard | Q/ASF01 |
Compliance | IEC 61010-1: Pollution Class 2 |
Laser Safety | IEC 60825-1 Class 2, 650 nm, < 1 mW |
Ingress Protection Rating | IP 54 per IEC 60529 |
Warranty | 3 years |