Key features

  • VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
  • Large backlit display
  • CAT IV 600 V safety rated

Product overview: Fluke 113 Digital Multimeter

The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems. The 113 features a large, backlit display for easy visibility in low-lit work environments. Plus, the integrated holster includes probe holders on the back, so your test leads can always be kept organized and where you need them.

Make measurements quickly with the 113

Whether you’re a utility worker, linesman, electrician, technician, anyone else working with basic electrical testing, the Fluke 113 includes the measurement features you need to tackle your job. The Fluke VCHEK™ LoZ low impedance measurement function lets users perform tests for voltage or continuity from the same dial position.

Please note that low impedance LoZ measurements will cause a low load on a circuit protected by a RCD, which will trip powered GFCI and RCD circuits when measuring Phase to Earth.

The meter also displays AC or DC voltage, depending on what was detected, while also rejecting ghost voltages from adjacent wires.  If no voltage is detected, a continuity test is performed. The Min/Max function lets you record signal fluctuations.

The Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.

Specifications: Fluke 113 Digital Multimeter

Specifications
VCHEK1 2 3Range6.000 V / 60.00 V / 600.0 V
Resolution0.001 V / 0.01 V/ 0.1 V
AccuracyDC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Diode test4Range2.000 V
Resolution0.001 V
Accuracy2.0% + 3
Continuity4AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ω4Range600.0 Ω / 6.000 kΩ / 60.00 kΩ
Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ
Accuracy0.9% + 2 / 0.9% + 1 / 0.9% + 1
Capacitance4Range1000 nF / 10.00 μF / 100.0 μF / 9999 μF
Resolution1 nF / 0.01 μF / 0.1 μF / 1 μF
Accuracy1.9% + 2
100 μF - 1000 μF: 1.9% + 2
1000 μF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Specifications
Maximum voltage between any terminal and earth ground600 V
Display3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature-10°C to 50°C (14°F to 122°F)
Storage temperature-40°C to 60°C (-22°F to 140°F)
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude2,000 m
Storage altitude10,000 m
Relative humidity95% to 30°C
75% to 40°C
45% to 50°C
Battery type9 Volt Alkaline, IEC 6F22
Battery lifeAlkaline: 300 hours typical, without backlight
Size (H x W x L)167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight13.0 oz (404 g)
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600V
EMI regulationsComplies with FCC Part 15, Class B
Specifications
VCHEKInput impedance (nominal)~3 kΩ < 300 pF
VCHEKCommon mode rejection ratio
(1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
ΩOpen circuit test voltage< 2.7 VDC
Full scale voltage< 0.7 VDC
Diode testOpen circuit test voltage2.7 VDC
Full scale voltage2.000 VDC
ΩShort circuit current< 350 μA
Diode testShort circuit current< 1.0 mA

Models: Fluke 113 Digital Multimeter

Fluke 113
Fluke 113 Digital Multimeter

Buy it

Includes:

  • Fluke TL75 test leads
  • Holster
  • Users manual
  • and 9 V battery (installed)

Is the LOZ function practically always active? Does it recognize the &ldquo;ghost voltage&rdquo;?

Asked by: Deamon
The Fluke-113 LOZ function means the input impedance is Lower than a typical 10M ohm input impedance. The purpose for the LOZ is to prevent the meter from showing Ghost Voltage.
Answered by: FlukeCorporation
Date published: 2024-09-25
  • y_2024, m_11, d_20, h_14CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_3739292598324, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 117.35ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Great basic voltmeter Fluke quality in a simple meter that provides basic functions. Perfect for a novice handyman.
Date published: 2023-08-12
Rated 2 out of 5 by from This meter is not worthy of the FLUKE name I have encountered several 113 meters which provided false readings on DC output from driver boards. I suggest a model where you select whether you desire AC/ DC/ Ohms, ect. I love and trust my Fluke products with the exception of the 113 meters. I use my 373, 117, 787, 287, and AC1 on a regular basis.
Date published: 2020-11-18
Rated 5 out of 5 by from Great multimeter A simple but very easy to use multimeter that makes it very versatile. From an apprentice to a master, this is a great meter!
Date published: 2017-01-01
Rated 4 out of 5 by from Easy I'm a restaurant technician and I use this meter daily the ease of use while crammed into small space the case and strap with the magnet is great most of the features I need on one device great job
Date published: 2016-12-10
Rated 5 out of 5 by from Great Tool This is another great product like we always get from fluke, its my favorite tools company, I bought this tool few months ago and like always this tool make my work easy. easy to use and accurate reading. I recommend it for everyone. thank you fluke
Date published: 2016-12-08
Rated 5 out of 5 by from NICE MULTIMETER IT IS A PERFECT METER FOR USE AROUND THE HOUSE OR IN MY SHOP. I USE FOR EVERYTHING ELECTRICAN AND YOU DONT NEED TO BE AN ELECTRICAL ENGINEER TO USE IT.
Date published: 2016-12-08
Rated 5 out of 5 by from Simple and Relaible As a Alarm technician this meter completely satisfy all of my needs, Simple to operate, accurate and reliable. This is my second one , the first one I left on the job site and lost it. So now I am on my second 113 . At first I was skeptical of the Full auto voltage detection future, but now I fully trust my meter, as it prove accuracy over and over again, it do have some tricks under the sleeve so read the manual to unleash full potential of the multimeter 113 , Highly recommended
Date published: 2016-12-08
Rated 5 out of 5 by from Perfect starter! My wife bought me this when I went back to school for my Electrical Engineering degree and it has stayed with me since! I was not overwhelmed with features making me more confused during my learning process. It helped me master my craft and become the professional I am today! Thanks to my Wife and Fluke!!!!
Date published: 2016-12-07
  • y_2024, m_11, d_21, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_10
  • loc_en_US, sid_3739292598324, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 28.84ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.