PPCK+ v1.00m Embedded Software (.bin)
TITLE | VER | USE WITH |
PPCK+™ | 1.00m 2005.01.05 | PPCK+ |
Instructions: | ||
Download the file. Run Winflash and select the file downloaded as the file to write to the product. Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox. If your product has an model number ending in "-AF", it requires specific "-AF" embedded software. The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center. If the update isn't performed properly, your product will be inoperable until it is. | ||
Updates Include: | ||
Ver 1.00m (2005 Jan 05) Fix: Setting fluid head medium to Air would cause a memory error when power was cycled. Ver 1.00l (2004 Apr 13) ADD: Support use of newer 20bit barometers in PPCK (added resolution is not used). Ver 1.00k (2003 Jan 02) CHG: "PASSTHRU" and "#" commands no longer time out after waiting 2 sec. PPCK+ will reply to any messages received from COM2 until the next remote command is sent FIX: Allow remote command delimiters ',' and ';' to have leading and trailing whitespaces CHG: Pass thru command separator (';') when using the '#' command FIX: Allow Down excursions when over the UL pressure. FIX: Reply as expected to Enhanced mode GPIB queries "ZNATERR:XX?" and "ZOFFSET:XX?" FIX: First excursion after executing the "*RST" or RESET command could be erratic. FIX: VENT operation failing after executing the "*RST" or RESET command FIX: The internal clock's seconds would be set to '00' each time the time menu is entered. Ver 1.00j (factory only) Ver 1.00i (2002 Mar 22) FIX: Power up in the last range used rather than in range H3 with last range used indicated. Ver 1.00h (2002 Feb 18) FIX: In static mode, if the hold setting was very tight (10 % of the default) the PPCK+ would never achieve a READY condition. FIX: GPIB bus would hang if a single character was sent as a command. ADD: If the pressure on the RPT exceeds the user UL setting, "OL" will appear as the first 2 char in reply to a "SR" or "PR" remote command. ADD: If the pressure on the RPT exceeds the factory over pressure limit, "OP" will appear as the first 2 char in reply to a "SR" or "PR" remote command. FIX: "Down" generations are allowed when the RPT is over the upper limit. Ver 1.00g (2001 Dec 03) FIX: Negative head entries would revert to positive values if no entry in the menu made. FIX: "Head" remote command response. FIX: Boolean replies to remote commands using the GPIB interface in enhanced mode would include the original command instead of just the reply of '0' or '1' as expected FIX: Non query remote command errors when using the GPIB interface in enhanced mode would result in a "ERR# nn" reply. Only query type commands should reply. FIX: The "MSS" bit of the "STB" status register was being set even if all events are masked (SRE=0) ADD: "RSE" and "RSR" remote commands Ver 1.00f (2001 Oct 18) FIX: Pass through communications on COM2 ("#" command). Ver 1.00e (2001 Oct 04) FIX: The "PASSTHRU" command ("#xxxxx) now functions. FIX: Occasional GPIB communications avoid interface hang ups when the local GPIB "DCL" command was sent. IMPROVE: Static control mode operation with hold limits of < 10 % of default limits. Ver 1.00 Rev d (2001 Feb 28) FIX: InWa ref temp menu selections." ADD: Allow selection of ""none"" in the punit setup to allow deleting a previously setup pressure unit." CHG: Enhance pressure control. Ver 1.00c (2001 Jan 16) Enhanced pressure control for certain situations. |