Fluke 1587/ET Advanced Electrical Troubleshooting Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.08ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 1587/ET Advanced Electrical Troubleshooting Kit
Discontinued

Key features

Fluke 1587 Insulation Multimeter

  • With the Fluke 1587, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease.
  • Two products in one: Powerful and full-featured multimeter.
  • Ideal for work on motors, cables, and switch gear.
  • Large display with backlight.
  • Filter for motor drive measurements.
  • Insulation test (0.01 MΩ to 2 GΩ).
  • Insulation test voltages (50 V, 100 V, 250 V, 500 V, 1000 V) for many applications.
  • CAT III 1000 V /CAT IV 600 V overvoltage rating for added user protection.

Fluke i400 Current Clamp

  • Use the Fluke i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit.
  • Use with your Fluke 1587 to measure 1A AC to 400 A AC.
  • 1 mA/Amp output guarantees easy reading.
  • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection.
  • Specially designed to offer maximum utility in a very compact shape.
  • Maximum conductor: Ø 32 mm.

Fluke 62 MAX+ IR Thermometer

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.
This product is discontinued or reclassified

Product overview: Fluke 1587/ET Advanced Electrical Troubleshooting Kit

The products in this kit have been specifically selected for both troubleshooting and preventative maintenance applications.

Establishing preventative maintenance programs are becoming critical to maintaining the uptime of electrical equipment and can significantly reduce both planned and unplanned downtime. Unplanned downtime costs are difficult to calculate, but often significant. For some industries, it can represent 1% - 3% of revenue (potentially 30% - 40% of profits) annually.

Includes a Fluke 1587 Insulation Multimeter, Fluke i400 Current Clamp, and a Fluke 62 Mini Infrared Thermometer.

  • With the Fluke 1587, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease.
  • Use the Fluke i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit.
  • Check for hot spots and measure temperature with the Fluke 62 Mini non-contact thermometer.

Specifications: Fluke 1587/ET Advanced Electrical Troubleshooting Kit

Fluke 1587 Insulation Multimeters

Specifications
Voltage DCMaximum voltage1000 V
Accuracy±(0.09% + 2)
Maximum resolution0.001V
Voltage ACMaximum voltage1000 V
Accuracy±(2% + 3)
AC bandwidth5 kHz1
1. With low pass filter; 3 db @ 800 Hz
Maximum resolution0.1 mV
Current DCMaximum amps400 mA
Amps accuracy±(0.2% + 2)
Maximum Resolution0.01 mA
Current ACMaximum amps400 mA
Amps accuracy±(1.5% + 2) 1
1. 1 kHz bandwidth
Maximum resolution0.01 mA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.9% + 2)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
Accuracy±(1.2% + 2)
Maximum resolution1 nF
FrequencyMaximum frequency100 kHz
Accuracy±(0.1% + 1)
Maximum resolution0.01 Hz
Temperature measurement-40.0°C to 537°C
-40.0°F to 998°F
excluding probe
Diode testRange6 V
Resolution1 mV
Accuracy±(2% + 1)
Insulation Test
Minimum test current @ 1 kΩ/V1 mA
Test voltages50, 100, 250, 500, 1000 V
Maximum resistance per test voltage50 V
100 V
250 V
500 V
1000 V2 GΩ
Maximum resolution per test voltage50 V0.01 MΩ
100 V0.01 MΩ
250 V0.1 MΩ
500 V0.1 MΩ
1000 V0.1 MΩ
Accuracy per test voltage50 V±(3% + 5)
100 V±(3% + 5)
250 V±(1.5% + 5)
500 V±(1.5% + 5)
1000 V±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Environmental Specifications
Operating temperature–20°C to +55°C
Storage temperature-40°C to +60°C
Humidity (without condensation)0% - 95% (10°C – 30°C)
0% - 75% (30°C – 40°C)
0% - 40% (40°C – 55°C)
Operating altitude2000 m
Safety Specifications
Overvoltage categoryComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency approvals2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical and General Specifications
Size203 x 100 x 50 mm (with holster)
Weight624 g
Warranty3 years
Battery life AlkalineMeter use1000 hours
Insulation test useMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP RatingIP40
 

Fluke i400 AC Current Clamp

Specifications
Nominal current range400 A
Continuous current range1 A - 400 A
Maximum non-destructive current1000 A
Lowest measurable current1 A
Basic accuracy2% + 0.06 A
(45 - 400 Hz)
(% reading + floorspec)
Useable frequency5 Hz - 20 kHz
Output level(s)1 mA/A
Safety Specifications
SafetyCAT IV 600 V, CAT III, 1000 V
Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty1 year
Maximum conductor diameter32 mm (1.25 in)
Maximum conductor size (busbar)750 MCM
Output cable length1.5 m (59 in)
Shrouded banana plugsYes
 

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range-30°C to 650°C (-22°F to 1202°F)
Accuracy±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%)Fluke 62 MAX+< 300 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical resolution12:1 (calculated at 90% energy)
Display resolution0.1°C (0.2°F)
Repeatability of readings±0.5% of reading or < ±0.5°C (1°F), whichever is greater
PowerAA battery
Battery life8 hours with laser and backlight on
Physical specificationsWeight255 g (8.99 oz)
Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
IP ratingIP 54 per IEC 60529
Drop test3 meters
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006 EN 61326-2:2006
Standards and agency approvalComplianceEN/IEC 61010-1: 2001
Laser safetyFDA and EN 60825-1 Class II

Models: Fluke 1587/ET Advanced Electrical Troubleshooting Kit

Fluke 1587/ET Kit
Fluke 1587/ET Advanced Electrical Troubleshooting Kit

Includes:

  • Fluke 1587 Insulation Multimeter
  • Fluke i400 Current Clamp
  • Fluke 62 MAX+ IR Thermometer
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 24.7ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.12ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.