5627A | Precision Thermometer, RTD Temperature Probe

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 25.48ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 5627A Precision Thermometer, RTD Temperature Probe
  • 5627A Precision Thermometer, RTD Temperature Probe
  • 5627A Precision Thermometer, RTD Temperature Probe
  • 5627A Precision Thermometer, RTD Temperature Probe

Key features

  • Temperature range up to 420 °C.
  • Accuracy of up to ± 0.025 °C.
  • NVLAP-accredited calibration.
  • Three different length options, with both six- and nine-inch models covering a temperature range of -200 °C to 300 °C.

Product overview: 5627A | Precision Thermometer, RTD Temperature Probe

One of the best features of this RTD sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a precision thermometer or RTD temperature probe that’s less accurate than your meter?

The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.)

Six- and nine-inch 5627A precision thermometers are calibrated at –196 °C, –38 °C, 0 °C, 200 °C, and 300 °C. For 12-inch versions of these precision thermometers, the point at 300 °C is replaced by a calibration point at 420 °C.

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer, lab code 200706-0.

This RTD temperature probe is an excellent value for a precision thermometer. It has the price-to-accuracy and price-to-durability ratios you should demand in all of the precision thermometers you buy!

Specifications: 5627A | Precision Thermometer, RTD Temperature Probe

Specifications
ResistanceNominal 100 Ω
Temperature Coefficient0.00385 Ω/Ω/ °C nominal
Temperature Range−200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C)
Drift Rate (k=2)± 0.04 °C at 0 °C after 100 hours at 420 °C
Sheath Material316 Stainless Steel
LeadsPTFE-insulated, nickel-plated stranded copper, 22 AWG
TerminationSpecify. See Ordering Information.
Time ConstantFour seconds maximum for 63.2 % response to step change in water moving at 3 fps.
Bending RadiusSheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
CalibrationIncludes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9).
ITS-90 coefficients included.
ImmersionAt least 100 mm (4 in) recommended
Calibrated Accuracy† (k=2)± 0.026 °C at -196 °C
± 0.046 °C at 0 °C
± 0.077 °C at 200 °C
± 0.124 °C at 420 °C
Size5627A-12: 305 mm x 6.35 mm (12 in x 1/4 in)
5627A-9: 229 mm x 4.7 mm (9 in x 3/16 in)
5627A-6: 152 mm x 4.7 mm (6 in x 3/16 in)
†Includes calibration uncertainty and 100 hr drift.

Models: 5627A | Precision Thermometer, RTD Temperature Probe

5627A Precision Thermometer, RTD Temperature Probe
Precision Thermometer, RTD Temperature Probe

Buy it
5627A-6-X
Secondary PRT, 152 mm x 4.7 mm (6 x 3/16 in), –200 °C to 300 °C

Buy it
(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).
5627A-9-X
Secondary PRT, 229 mm x 4.7 mm (9 x 3/16 in), –200 °C to 300 °C

Buy it
(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).
5627A-12-X
Secondary PRT, 305 mm x 6.35 mm (12 x 1/4 in), –200 °C to 420 °C

Buy it
(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 60.99ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.66ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.