Key features

  • Current Range: 0.1 to 100A DC or 0.1 to 100A AC
  • Basic Accuracy (DC to 1kHz):
    100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
    10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA
    40A to 80A +/- 12% of reading + 50mA
    80 to 100A +/- 15% of reading
  • Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
  • Bandwidth: 1Hz to 20kHz
  • Working Voltage: 600V AC rms
  • Maximum Conductor Size: 11.8 mm (.46 inch) diameter
  • Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Product overview: Fluke 80i-110s AC/DC Current Clamp

The 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.

Useful resources and rugged tools for Solar professionals

Specifications: Fluke 80i-110s AC/DC Current Clamp

Specifications
Nominal current range10 A, AC/DC
100 A, AC/DC
Continuous current range0.1 A - 10 A AC/DC
1 A - 100 A AC/DC
Maximum non-destructive current140 A - 2 kHz
Lowest measurable current0.1 A
Basic accuracy100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA
10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA
40 A to 80 A ±12% of reading +50 mA
80 to 100 A ±15% of reading
Useable frequencyDC - 100 kHz
Output level(s)10 A range: 100 mV/A
100 A range: 10 mV/A
Zero error adjustmentYes
Safety Specifications
SafetyCAT II, 600 V
CAT III, 300 V
Maximum voltage600 V
Mechanical and General Specifications
Warranty1 year
Battery life9 V, 55 h
Maximum conductor diameter11.8 mm
Output cable length1.6 m
BNC adapterYes

Models: Fluke 80i-110s AC/DC Current Clamp

Fluke 80i 110s

Buy it

What is the maximum current it can read the below mentioned Current Clamp Fluke 80i-110s AC/DC Current Clamp

Asked by: Prabakaran
  • y_2024, m_11, d_21, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_3739330379828, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 116.74ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 168.28ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.