This guide summarizes the functions, accuracies and targeted workload of every Fluke Calibration electrical calibrator; including electrical multi-product calibrators, multifunction calibrators, oscilloscope calibrators, electrical tester calibrators, power and energy calibrators and standards, and precision process calibrators. This selection guide is intended to help you decide which calibrator best fits which class of test equipment and the associated performance levels required.
For additional help selecting an electrical calibrator,
Multi-Product Calibrators | Multifunction Calibrators | ||||
Workload | 5080A | 5540A | 5550A | 5560A | 5730A |
Analog/panel meters | |||||
High burden meters | YES | ||||
Low burden meters | |||||
DMMs | |||||
Basic DC V accuracy at 99 % | 100 ppm | 31 ppm | 11 ppm | 8 ppm | 4.5 ppm |
3.5 digits (typ. ± 0.3 % DC V) | |||||
4.5 digits (typ. ± 0.025 % DC V) | |||||
5.5 digits (typ. ± 0.015 % DC V) | |||||
6.5 digits (typ. ± 0.0030 % DC V) | |||||
7.5 digits (typ. ± 12 ppm DC V) | |||||
Temperature/pressure | |||||
RTD simulate | |||||
Thermocouple simulate | |||||
Thermocouple measure | |||||
Oscilloscopes | 1 channel | 1 to 5 channels | |||
200 MHz to 600 MHz | 200 MHz opt | 600 MHz opt | 600 MHz opt | 600 MHz opt | |
1.1 GHz | 1.1 GHz opt | 1.1 GHz opt | |||
2.1 GHz | 2.1 GHz opt | ||||
Safety testers | |||||
Megohm meters | MEG opt | ||||
Continuity | MEG opt | ||||
Power/energy | |||||
Wattmeters | |||||
Phase angle meters | |||||
Power analyzers | |||||
Power recorders | |||||
Watt-hour/energy meters | |||||
Other | |||||
Clamp meters | |||||
LCR meters | RC only | LRC | LRC | ||
Process calibrators | |||||
Data acquisition | |||||
Non sine waveforms | |||||
RF millivolt meters | 30 and 50 MHz WB opt | ||||
# of calibrator functions | 8 | 11 | 11 | 11 | 5 |
Oscilloscope Calibrators | Electrical Tester Calibrator | Power and Energy Calibrators | Temperature and Pressure Calibrator | ||
Workload | 9500B | 5322A | 6100B | 6105A | 7526A |
Analog/panel meters | |||||
Low burden meters | V DC and V AC | V DC, I DC and R | |||
DMMs | |||||
Basic DC V accuracy at 99 % | n/a | 1000 ppm | 112 ppm | 42 ppm | 40 ppm |
3.5 digits (typ. ± 0.3 % DC V) | V DC and V AC | V DC and V AC | |||
Temperature/pressure | |||||
RTD simulate | |||||
RTD measure | |||||
Thermocouple simulate | |||||
Thermocouple measure | |||||
Pressure modules | |||||
Oscilloscopes | 1 to 5 channels | ||||
200 MHz to 600 MHz | 600 MHz std | ||||
1.1 GHz | 9510 Head opt | ||||
2.1 GHz | |||||
3.2 GHz | 9530 Head opt | ||||
6.4 GHz | 9560 Head opt | ||||
25 ps fast edge (14 GHz) | 9550 Head opt | ||||
Safety testers | |||||
Hipot | |||||
Megohm meters | |||||
Installation | |||||
PATs | |||||
Continuity | |||||
Loop impedance | |||||
Leakage current | |||||
Ground bond | |||||
RCD/GFCI | |||||
Medical safety | |||||
Power/energy | |||||
Wattmeters | |||||
Harmonic analyzers | |||||
Flicker meters | |||||
Phase angle meters | |||||
Power analyzers | |||||
Power recorders | |||||
Secondary energy standards | |||||
Watt-hour/energy meters | |||||
Other | |||||
# of calibrator functions | 11+ | 9 | 8 | 8 | 9 |
Specifications subject to change without notice.