Search results

Only search for:
Found 147 results containing the words:product
  • PVA-1500 Series PV Analyzer, I-V Curve Tracer

    Measure and display I-V curves up to 1500V/30A, with advanced PV modeling, rapid sweeps, wireless setup, and automated data management.

    Products
  • PVA-1500HE2 I-V Curve Tracer, Insulation, Clamp and Multimeter Kit

    Optimize Solar Performance: PVA-1500HE2 PV Analyzer, 1587 FC Insulation Multimeter, 393 FC Clamp Meter & 87V Multimeter

    Products
  • COMPASS® for Pressure Software

    COMPASS® for Pressure Calibration Software is a universal platform for all of your pressure calibration software needs.

    Products
  • 5000A-RH/T Precision Humidity and Temperature Data Logger

    Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

    Products
  • 5080 / CAL Software

    Fluke Calibration 5080 / CAL calibration software for 5080A multi-product calibrator can quickly calibrate a wide range of analog & digital workload accurately.

    Products
  • 5502A Multi-Product Calibrator

    The 5502A Multi-Product Calibrator is the ideal electrical calibrator for metrology professionals who calibrate low-to-medium accuracy electrical instruments

    Products
  • 5520A High Performance Multi-Product Calibrators

    The Fluke 5520A multi-product calibrator has been upgraded to the 5522A. By clicking, you’ll go to the old 5520A page that has a link to the new 5522A.

    Products
  • 5502E Multi-Product Calibrator

    An accurate & economical solution if you need to calibrate digital multimeters, clamps, thermometers & other electronic test instruments. Learn more.

    Products
  • 5320A Multifunction Electrical Tester Calibrator

    5320A multifunction DC calibrator is an accurate, flexible instrument that allows you to calibrate many different models of electrical testers efficiently.

    Products
  • Fluke 393 with Solar Irradiance Meter and TLPV Test Leads

    Fluke 393 bundle with solar irradiance meter and TLPV leads for solar professionals.

    Products
  • Fluke 110 True-rms Digital Multimeter

    Compact True-RMS meter with large white LED backlight.

    Products
  • Fluke C37XT Protective EVA Hard Tool Case

    Durable EVA foam case and divider to safely carry most multimeters

    Products
  • 5790A AC Measurement Standard

    5790A AC measurement standard is compatible with current shunts & is designed for the most demanding calibration applications. Request a product quote today!

    Products
  • Calibration

    What Is Calibration?Calibration is configuring and verifying a measuring instrument's accuracy to ensure its readings match a known standard. Calibration is a foundational practice across healthcare, electronics, manufacturing, and environmental monitoring.Instruments naturally experience wear, drift, and environmental impact over time, which can compromise their performance. Calibration restores their accuracy and ensures consistent, reliable operation that aligns with regulatory and safety standards.Table...

    Article
  • How To Calibrate a Clamp Meter: A Step-By-Step Guide

    Technicians and other experts who work with electrical systems use clamp meters in a variety of settings, from testing products on the manufacturing floor to troubleshooting residential electrical systems. Professionals rely on these tools to measure electrical current and trust that their devices will make accurate assessments so they can do their jobs safely.Over time, clamp meters will lose accuracy and no longer measure within the manufacturer’s specifications (specs). By periodically calibrating...

    Article
  • What Harmonics Really Do to Data Center Uptime

    By Jason Axelson, Fluke Subject Matter Expert, Power QualityUptime is the lifeblood of data centers, whose customers depend on them to deliver 100% availability. Facility disruptions carry extreme consequences, including costly service-level agreement (SLA) penalties. Even though data centers are full of complex machines and systems, the most frequent cause of disruptions in data centers isn’t hardware or software. Instead, the number one cause of facility disruptions is power issues, which account...

    Article
  • Fluke Networks Support Plans

    .section-banner { padding-bottom: 20px; } .section-intro { padding-bottom: 40px; display: grid; grid-template-columns: 2fr 1fr; column-gap: 40px; } .section-intro img { width: 80%; } @media only screen and (max-width: 767px) { .section-intro { grid-template-columns: 1fr; } } .section-table-features { padding-bottom: 40px; } .table-networks { display: block; width: 100%; border-collapse: collapse; } .table-networks tbody { display: table; width: 100%; } .table-networks td { background-color: #fff;...

    Article
  • Calibration services

    CalNet®: The European Specialist in CalibrationFluke has its own calibrations laboratories in the United Kingdom, The Netherlands and Germany, and authorized service partners in most of the other countries in Europe. All These calibration laboratories work together as a single calibration network: CalNet.CalNet can issue the calibration certificates you need to meet ISO 9000 standards. CalNet guarantees traceability and access to the best calibration facilities the network can offer. Because of...

    Article
  • Loop Calibration and Maintenance with Fluke Tools

    Process instruments require periodic calibration and maintenance to ensure correct operation. This article contains information to help guide technicians through some of the more common loop calibration tasks using Fluke tools.Fluke loop calibrators are ideal for a wide variety of calibration applications. They include:Fluke 707 Loop CalibratorFluke 705 Loop CalibratorFluke 715 Volt/mA Loop CalibratorFluke 787B and 789 ProcessMeter™ tools The loop-powered isolator and the two-wire isolating transmitter...

    Article
  • How to choose a heat transfer fluid for your calibration bath

    The first thing you need to know about choosing the right heat transfer fluid (also known as a thermal fluid) for a calibration bath is that the options are vast, which can be intimidating if you don’t know what to look for. When it comes to selecting a suitable thermal fluid that is going to work for you, there is plenty to think about.Fluke Temperature Calibration FluidsThe good news is we’ve spent decades working with a wide variety of heat transfer fluids and we’ve already done a lot of...

    Article
  • Why Customers Love COMPASS® for Pressure Calibration Software

    Why Customers Love COMPASS® for Pressure Calibration Softwarewhy-customers-love-compass-for-pressure-calibration-softwareCustomers are talking about COMPASS®® for Pressure calibration software. Here’s what they are saying about how they use it, why they chose it, and how they like it.Question: Describe the Applications for Which you are Using COMPASS® for Pressure Software“I work in a nuclear power station. The Nuclear Regulatory Commission (NRC) requires that the test equipment we use at...

    Article
  • Understanding Voltage Tester Pens

    Voltage tester pens offer a quick and non-invasive method to detect live circuits. Understanding their operation, proper usage, and how they compare to tools like multimeters can help you choose the right instrument for your electrical tasks.

    Article
  • How to Identify and Label Low-Voltage Cables in Utility Plants

    By Michael Crepps, Fluke Product Application SpecialistIn utility plants, accurate identification and labeling of low-voltage cables are essential for maintaining safety and efficiency. Properly labeled cables facilitate easier maintenance, troubleshooting, and system upgrades. A wire tracer, such as the Fluke 2062 Advanced Pro Wire Tracer Kit, is an indispensable tool for accurately identifying and labeling low-voltage cables in utility environments (CAT IV 600V rated). This article provides a step-by-step...

    Article
  • We get your machines to run smoothly again

    #pane-service-articles { background: #fff; } #pane-service-articles .hero { background-image: linear-gradient(180deg, rgba(0, 0, 0, 0.55) 0%, rgba(0, 0, 0, 0.35) 100%), url("https://pruftechnik-dev.s3.us-west-1.amazonaws.com/wp-content/uploads/2025/03/06185338/Cardan-shaft-alignment_geometrical-Alignment_Service_Hero_1920x600px_PageTitle.webp"); background-size: cover; background-position: center; min-height: 450px; } #pane-service-articles .banner { background: #282828; color: #eee; padding: 40px...

    Article
  • ParAlign Roll Alignment Services from the innovators of inertial alignment.

    #pane-service-articles { background: #fff; } #pane-service-articles .container { padding: 0 20px; } #pane-service-articles .tab-blocks { display: grid; gap: 40px; } #pane-service-articles .tab-block-title { font-size: 30px; color: #fff; letter-spacing: 0.5px; margin-bottom: 6px; } #pane-service-articles .tab-block-subtitle { font-size: 16px; color: #fff; margin-bottom: 16px; } #pane-service-articles .btn { display: inline-flex; align-items: center; gap: 8px; padding: 1.1rem 3rem; background: #ffc20e;...

    Article
  • Why Thermal and Power Quality Monitoring Are Critical for CDU Troubleshooting

    by Jason Axelson, Subject Matter Expert at Fluke, Power QualityIn today's high-density server environments, artificial intelligence (AI) workloads and other processing-intensive computing applications generate heat faster than airflow alone can dissipate. Data centers are increasingly adopting liquid cooling for more effective thermal management.Continuous thermal imaging and power quality monitoring function as an early warning system against cyberattacks.Liquid coolant circulated directly to the...

    Article
  • What Do Leaks Do to Compressed Air Systems?

    Compressed air systems are often considered a critical utility in manufacturing, alongside electricity, water, and natural gas. They power tools, drive automation, move materials, and support processes in various industries, from automotive to food production. Because these systems are vital to operations, even a minor issue can affect production. One of the most common and costly issues is the presence of leaks.Robotics equipment with air leaks in the pneumatic suction cups.While a leak might seem...

    Article
  • Release: MET/CONNECT version 2.2.1 (with MET/CAL version 11.2.0)

    MET/CONNECT v 2.2.1 with MET/CAL v 11.2.0 (2.0 GB)Document(s): MET/CONNECT 2.2.1 ReadMe (159 KB) MET/CAL 11.2.0 ReadMe (472 KB) MET/CONNECT Installation Guide (742 KB) MET/CONNECT API Reference (825 KB)  Current MET/CONNECT Customers: What you need to know prior to updatingThe MET/CONNECT version 2.2.1 and MET/CAL version 11.2.0 release is an update to previous MET/CONNECT and MET/CAL software. This update includes new features, bug fixes, and minor updates.This installer can initiate a new...

    Article
  • How to Locate Faults in Low-Voltage Utility Systems

    By Michael Crepps, Fluke Product Application SpecialistIn utility systems, locating faults quickly and accurately is crucial to minimize downtime and ensure the safety and reliability of the electrical infrastructure. Faults such as shorts, opens, and ground faults can disrupt operations and pose significant risks. A wire tracer is an essential tool for identifying and locating these faults in low-voltage systems up to 600 V AC. This application note provides a step-by-step guide for using a wire...

    Article
  • How to Perform Power Quality Analysis in Large-Scale Solar PV Systems

    By Jason Axelson, Fluke Subject Matter Expert, Power QualityLarge-scale solar PV systems are engineered for long-term output and stable operation. But issues like harmonic distortion, voltage unbalance, and inverter inefficiency can silently reduce energy yield and accelerate wear on critical assets.For experienced technicians, power quality analysis offers a path to early detection and correction, preserving uptime, improving inverter performance, and avoiding unplanned maintenance or regulatory...

    Article
  • How to Use a Circuit Breaker Finder for Home Renovations

    During home renovations, it’s common to encounter the need to identify and label circuits accurately to ensure safe and efficient electrical work. Whether you are adding new outlets, upgrading the electrical panel, or rewiring parts of the home, a circuit breaker finder is an essential tool. This application note provides a step-by-step guide on how to use a circuit breaker finder to identify circuits during a home renovation, ensuring accuracy and safety in your electrical projects.Scenario: Home...

    Article
  • Get Started with the Right Multimeter and Clamp Meter Pairing

    If you are new to electrical work, field service, or even serious DIY projects, your test tools are crucial. To begin, a digital multimeter (DMM) and a clamp meter combination are essential if you plan to work on any electrical system.This pairing provides the foundation for your test tool kit, enabling you to test safely, diagnose confidently, and work efficiently from the start. However, selecting the right pair is challenging.Fluke offers a variety of DMM and clamp meter combinations to suit diverse...

    Article
  • Improving Uptime and Efficiency Through Power Quality Audits

    By Jason Axelson, Fluke Subject Matter Expert, Power QualityThe actual cost of poor power quality extends beyond equipment replacement. It encompasses downtime, missed deadlines, and lost productivity. Power quality audits and analysis tools can provide clarity and operational assurance.Often overlooked, power quality — defined as the effectiveness with which electrical power supports reliable device operation — can be the underlying cause of equipment failure, production delays, and increased...

    Article
  • Case Study: Expediting Compressed Air System Leak Detection

    Even the smallest air leaks can compound product and energy waste and lost production time—especially for a production line that cannot function without compressed air to run its tools and processes.

    Article
  • Levels of Calibration Services

    .custom-grid .intro { padding-bottom: 30px; } .custom-grid .two-columns { display: grid; grid-template-columns: 1fr 1fr; grid-column-gap: 40px; } @media screen and (max-width: 768px) { .custom-grid .two-columns { grid-template-columns: 1fr; } } .custom-grid .services-card { margin-bottom: 30px; padding: 25px; background-color: #FFFFFF; } .custom-grid .services-card h2 { color: #5D5D5D; } .custom-grid .services-card .icon-group { display: grid; grid-template-columns: 50px 1fr; grid-column-gap: 25px;...

    Article
  • Backer Group Measures Remotely and Unlocks Data-Driven Insights With Fluke Connect

    Engineers at heat solutions company Backer Springfield have improved communication, compliance, and safety, while unlocking dynamic insights through Fluke Connect.

    Article
  • Why Ignoring Compressed Air System Leaks Risks ISO 50001 Compliance — and Profitability

    By Justin Sheard, Fluke Acoustic Imaging ExpertCompressed air systems are essential to countless industrial operations, powering everything from production tools to material handling equipment. However, for many facilities, these systems are also a hidden source of energy waste and operational risk.Operational consequences of compressed air leaks.Leaks in a compressed air system might seem like a minor nuisance, a mere hiss in the background or a slight dip in system pressure. However, they can undermine...

    Article
  • Release: MET/TEAM version 3.4.0 (with MET/CAL version 11.2.0)

    Release: MET/TEAM version 3.4.0 (with MET/CAL version 11.2.0) (.iso)Documents:MET/TEAM 3.4.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/CAL 11.2.0 Read Me (.pdf)Updating to METTEAM 3.4.0 and METCAL 11.2.0 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.4.0 release is a minor update to MET/TEAM software. The MET/CAL version 11.2.0 release is a minor update to MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    Article
  • How to Troubleshoot Overheating in CRAC Units with Thermal Imaging

    By Justin Sheard, Product Manager, Thermal and Acoustic ImagingData centers power our digital world but consume massive amounts of energy, generating significant heat. When this heat is not controlled with CRAC units, it can harm delicate electronics and lead to costly downtime.Overheating is a common failure mode for CRAC units. If left unaddressed, overheating can lead to downtime and wasted energy as units struggle to maintain the correct environment. Promptly identifying the issue is essential...

    Article
  • Battery Testing Strategies for Data Centers

    By Jason Axelson, Fluke Subject Matter Expert, Power QualityBattery systems are the primary safeguard between a disturbance on the grid and a service-impacting outage. Whether your site relies on legacy VRLA, vented VLA, NiCd, or modern Li-ion, proactive testing and monitoring are essential components of an uptime strategy. While DCIM platforms consolidate telemetry, decision-makers still need independent, actionable verification of battery health, documented to industry standards for both risk management...

    Article
  • Data Acquisition: Speed, Accuracy, and Resolution Specs

    The objective of this article is to explain the trade-off between analog-to-digital (A/D) sampling speed and accuracy, and the difference between accuracy and resolution.One specification important to almost every data acquisition application is measurement accuracy. Studies show that data acquisition equipment users feel that the most important aspect of such systems is the accuracy and integrity of the data.Unfortunately, accuracy is often misunderstood or misinterpreted by users, and often exploited...

    Article
  • Why DC ground faults are dangerous

    Ground faults in solar PV systems can cause damage, bring systems down, and create hazardous conditions for personnel. Here's what to know.

    Article
  • Proper calibration of industrial temperature process systems

    Temperature measurement is a critical parameter in many industrial processes. As a result, these processes generally use installed thermometers or temperature transducers. Proper calibration of these installed systems has always presented a challenge. Traditionally, simulators are used to provide in-situ calibration of the electronic portions of these systems. Although this is a valid technique for the calibration of the electronics, considerable inaccuracies are introduced by the sensor itself.The...

    Article
  • Calibrating industrial temperature sensors

    Industrial temperature measurement and control are two of the most dynamic subsets of the process control industry. Sensors are manufactured in every size, shape, length, and accuracy imaginable to fulfill a specific temperature application. In many cases, probes and probe assemblies are chosen not based on the application’s success, but on other factors such as price, expediency, or availability.The calibration of an industrial temperature sensor should be well thought out in the early design...

    Article
  • LabView Drivers

    LabVIEW driver for PPC3 and PPCH (.exe)Additional Downloads:LabVIEW driver for PPC2+ and PPCK+ (.exe)LabVIEW driver for PPC2 and PPCK (.exe)LabVIEW driver for RPM3 (.exe)LabVIEW driver for RPM4 (.exe)LabVIEW driver for molbox (.exe)LabVIEW driver for molbox RFM (.exe)LabView® drivers for Pressure ProductsUSE WITHVERDOWNLOADPPC3™DescriptionLabView is a registered trademark of National Instruments Corp.Instructions:As noted by the table, some of the LabView Drivers support more than one product....

    Article
  • MFC-CB v1.00b Embedded Software

    MFC-CB v1.00b Embedded Software (.bin)TITLEVERUSE WITHMFC-CB™1.00b2005.10.19MFC-CBTITLEVERUSE WITHMFC-CB™1.00b2005.10.19MFC-CBInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    Article
  • molbox RFM™ v1.20d Embedded Software

    molbox RFM™ v1.20d Embedded Software (.bin)TITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMTITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of...

    Article
  • molbox1 v5.41 Embedded Software

    molbox1 v5.41 Embedded Software (.bin)TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    Article
  • molbox1+ or molbox1+S v6.01 Embedded Software

    molbox1+ or molbox1+S v6.01 Embedded Software (.bin)TITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+STITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+SThis flash is intended ONLY for molbox1+ or molbox1+S with the Fluke Calibration logo: on the front panel, serial number 2000 and above. Attempted use on any other molbox will result in an inoperable molbox unless the molbox1 hardware is upgraded to a molbox1+.For a molbox1 WITHOUT the Fluke Calibration logo,...

    Article
  • COMPASS® for Pressure Version 4 Release Notes

    Download COMPASS® for PressureVersion 4 Releases4.2 (2012.07.27)ADDCP-115%4COMPASS for Pressure now supports the calibration functions of CalTool for RPTs. This functionality allows users to fully adjust and report calibration results for supported Fluke products. Sample tests are included with COMPASS that support automated collection of as received data and as left data with an adjustment in between. Review the CalTool for RPTs application note for details. The COMPASS CalTool implementation supports...

    Article
  • 6270A Embedded Software, Update by Serial RS-232 Port

    6270A Embedded Software, Update by Serial RS-232 Port (.zip)Click here to update by USB.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the RS-232 serial port on the rear panel of the 6270AThe below procedure updates the main firmware. Updating...

    Article
  • CalTool for Analog Free Utility

    CalTool for Analog Free Utility (.exe)TITLEVERUSE WITHDOCUMENTSCalTool™ for Analog Free Utility1.00TITLEVERUSE WITHDOCUMENTSCalTool™ for Analog Free Utility1.002003.01.27molbox1 (w/MFC option installed) & MFC-CBHelp File IncludedInstructions:Download and run the file. The installation program will prompt you through the process.DescriptionCalTool™ for Analog is used to calibrate the analog circuits of molbox1 and MFC-CB. CalTool for Analog is PC based application that assists in the calibration...

    Article
  • CalTool for RPTs Free Utility

    CalTool for RPTs Free Utility (57.61 MB)TITLEVERUSE WITHDOCUMENTSCalTool™ for RPTs Free Utility1.10.0.252021.05.11PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCK, PPCK+, RPM1, RPM3, RPM4, PPCH, PPCH-G, molbox1, molbox RFMCalTool for RPTs uses an on line HTML help system that is installed with the program. Install and run CalTool then select the [Help] menu to access the help system.(Note: As a result of PC specific security settings the help may not display correctly when viewed over the Internet....

    Article
  • 8270A/8370A Embedded Software

    8270A/8370A Embedded Software (.zip)TITLEUSE WITH8270A/8370A8270A/8370AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 8270A/8370AUpdating the firmware (embedded software) of an 8270A or 8370A pressure controller requires only a...

    Article
  • 8588A & 8558A Firmware, Update by USB

    8588A & 8558A Firmware, Update by USB (.zip)TITLEUSE WITH8588A & 8558AAllThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by USBFluke 85xx update v1.32To update a Fluke 8588A/8558AAn empty USB stick (of greater than 10Mbytes) will be required. This should be formatted using...

    Article
  • 6270A Embedded Software, Update by USB

    6270A Embedded Software, Update by USB (.zip)Additional Downloads:6270 PCM v104 USB (.zip)Click here to update by serial RS-232 port.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 6270AUpdating the PCM (Pressure...

    Article
  • Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0)

    Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.iso)Documents:MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.pdf)MET/TEAM 3.0.0 ReadMe (.pdf)MET/CAL 10.2.0 ReadMe (.pdf)MET/TEAM Installation Guide (Updated for version 3.0) (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.0.0 and MET/CAL version 10.2.0 release is a a major update to MET/TEAM and MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    Article
  • 96270A RF Reference Source Firmware Upgrade

    96270A RF Reference Source Firmware Upgrade (.ldr)Serial Number RangeBackward CompatibilityDateFirmware RevisionExplanationsAllAll previous versions 96270AApril 2, 2019V1.13Extend capability of previous 96270A models to accept Rohde & Schwarz NRPxxT power sensors.Full list of all sensors recognised by 96270 with install firmware V1.13 installed:Older NRP-Z51, NRP-Z52, NRP-Z55, NRP-Z56, NRP-Z57and NRP-Z58Now extended to include:New: NRP18T, NRP18TN, NRP33T, NRP33TN, NRP40T, NRP40TN, NRP50T, NRP50TN,...

    Article
  • COMPASS for Pressure Calibration Software Download/Upgrade

    COMPASS for Pressure Basic, Demo (.exe)COMPASS for Pressure Basic, Upgrade (.exe)COMPASS for Pressure Enhanced, Demo (.exe)COMPASS for Pressure Enhanced, Upgrade (.exe)TITLEVERUSE WITHDOCUMENTSCOMPASS®for Pressure™5.3.02025.09.15FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456, 2271A, 6270A, 8270A, 8370A,Third party piston gauges, pressure controllers and T&M hardware.Example Setup DatabaseA COMPASS...

    Article
  • Why is Calibration Important?

    Table of ContentsCalibration DefinitionWhy Is Calibration Important?What Happens When You Calibrate?Calibration in Our Daily LivesInstrument Calibration SchemesThe Importance of Calibration in the FutureDifferent Perspectives on the Significance of CalibrationThe Benefits and Purpose of CalibrationWhat Are the Costs and Risks of Skipping Calibration?Summary / TL;DRCalibration DefinitionCalibration is the act of testing a measurement instrument's accuracy to compare it to a known standard. The goal...

    Article
  • Analysis: I-V curve tracing of high efficiency solar panels

    This application note will describe the physics of high efficiency solar panels and what happens during an I-V curve sweep. It will also discuss proper measurement techniques, the challenges of measuring strings of high efficiency solar modules, and the trade-offs of different curve tracing architectures.Fluke PVA-1500HE2 Solmetric PV Analyzer High Efficiency IV Curve TracerHigh efficiency solar modules have a high capacitance, which can cause errors when measuring I-V curves if not measured properly....

    Article
  • Maximizing Photovoltaic Efficiency: Commissioning a PV System for Optimal Performance

    Solar energy expert guidance on how to design and commission a photovoltaic system for maximum performance including longevity of equipment, safety and ROI.

    Article
  • How to Troubleshoot a Non-Working Outlet with a Circuit Breaker Finder

    by Michael Crepps, Fluke Product Application SpecialistAs a residential electrician, you are often called upon to troubleshoot electrical issues in homes. One common problem you may encounter is a non-working outlet. Diagnosing and fixing this issue efficiently is crucial to maintaining client satisfaction and safety. This application note provides a step-by-step guide on how to use a circuit breaker finder to troubleshoot a non-working outlet, ensuring you can quickly identify and resolve the problem.Scenario:...

    Article
  • Inspect, Label, and Maintain: How to Use a Wire Tracer for Maintenance of Industrial Wiring

    By Michael Crepps, Fluke Product Application SpecialistPreventive maintenance is critical in industrial plants to ensure the reliability and longevity of electrical systems. Regular inspections and maintenance help to identify potential issues before they become significant problems, minimizing downtime and enhancing safety. A wire tracer is an essential tool for preventive maintenance, allowing technicians to accurately locate and assess the condition of electrical wiring. This application note...

    Article
  • Systematic Fault Detection and Electrical Maintenance with Advanced Wire Tracing

    By Michael Crepps, Fluke Product Application SpecialistIn industrial plants, maintaining the reliability and safety of electrical systems is critical due to the complexity and scale of operations. Electrical faults can lead to significant downtime and safety hazards. A wire tracer is an essential tool for troubleshooting and maintaining electrical systems, allowing technicians to accurately locate wires, identify faults, and ensure proper connections. This application note provides a step-by-step...

    Article
  • How to Troubleshoot Transient Voltages in Variable Frequency Drives Using a Digital Multimeter

    A digital multimeter (DMM) is the first tool most of us reach for when troubleshooting an electrical issue. It provides a variety of measurement features that can help isolate a problem or narrow down the list of potential issues. Troubleshoot Transient Voltages in VFDs Using a Digital MultimeterWhen troubleshooting a variable frequency drive (VFD), a multimeter is an excellent tool to start with. Variable frequency drives are motor controllers that vary the frequency and voltage of power supplied...

    Article
  • What Are the Different Types of Metrology?

    Metrology can be defined simply as the science of measurement, but it’s rarely that simple in practice. Measurements touch nearly every part of life, and that means metrology does as well. However, as a field, metrology is not a pillar. It’s made up of both larger subfields and more niche branches, and to better understand the work metrologists do every day, it’s important to know the differences between these types of metrology.Introduction to MetrologyAccording to The International Bureau...

    Article
  • Best Fluke Digital Multimeters Under $200: A Guide for Selecting Your First Meter

    Listen to the Podcast! Your browser does not support the audio element. Sean Anderson, Fluke Application SpecialistIf you're new to using a digital multimeter, choosing the right one can be overwhelming. Fortunately, Fluke offers a selection of high-quality, user-friendly multimeters under $200, perfect for beginners, hobbyists, and DIYers. In this guide, we'll introduce three excellent Fluke models, explain what they measure, explore their best applications, and help you choose the right one based...

    Article
  • What Can You Do with an Infrared Thermometer?

    An infrared thermometer is one of the most versatile diagnostic tools available today. From inspecting HVAC systems in commercial buildings to verifying product quality on a manufacturing line, infrared thermometers serve professionals across industries. Their value lies in the ability to measure surface temperatures quickly, safely, and without physical contact—making them ideal for hard-to-reach, moving, or hazardous objects.Infrared thermometers, like this Fluke 64 MAX, are small and light enough...

    Article
  • Aviation Maintenance and Safety: Leak Testing

    By Justin Sheard, Fluke Acoustic Imaging ExpertIn aviation, there is no room for uncertainty. Every component of an aircraft—from the pressurized fuselage to the smallest fuel line fitting—must meet rigorous standards of safety and performance. Leak and tightness testing is not only essential for the structural and functional integrity of aircraft systems, but also a core requirement in regulatory compliance, scheduled maintenance, and lifecycle support.Aircraft cabins must maintain stable pressurization...

    Article
  • Troubleshooting 10 Common Issues with the Fluke 116 HVAC Multimeter: An FAQ Guide

    HVAC technicians rely on their tools to diagnose and repair issues quickly and accurately. The Fluke 116 HVAC Digital Multimeter is built specifically for HVAC professionals, offering measurement capabilities like voltage, resistance, capacitance, temperature, and microamps. Below are 10 common HVAC issues and how to troubleshoot them effectively using the Fluke 116.

    Article
  • The New Fluke 417D Laser Distance Meter takes reliability and measurement time to the next level

    EVERETT, Wash., Sept. 17, 2019 – Fluke introduces its newest, most compact laser distance meter yet—the 417D Laser Distance Meter. The 417D speeds up layouts with instant, one-button measurements up to 131 feet (40 meters) and an accuracy of 0.08 inches (± 2 mm). This ultra-portable meter increases measurement efficiency while maximizing the reliability of measurements by reducing estimation errors, saving time and money.Designed for indoor and outdoor applications, the palm-sized 417D features...

    Article
  • Dominion Slashes 5540A Calibration Time with 8588A and Fluke Calibration Software

    SummaryDominion Global, a major distributor of Fluke products, works with a range of clients to develop custom technology solutions for operations and maintenance (O&M). At their service facility in Mexico City, metrologists wanted to find a faster, more affordable way to calibrate Fluke 55XX-series calibrators in-house.The team set up a new protocol combining the Fluke Reference Multimeter, Fluke 5540A Multi-Product Calibrator, and Fluke calibration software that cut calibration time, cost, and...

    Article
  • Fluke multimeter review: the Fluke 283 FC does it all

    By Sean Anderson, Fluke Application SpecialistLet’s be real — digital multimeters aren’t always thrilling to talk about. But if you’ve ever tried diagnosing a tricky electrical issue, you know how much easier life is when your DMM is fast, accurate, and built to handle whatever you throw at it.That’s where the Fluke 283 FC comes in. This meter is more than just rugged — it’s smart, precise, and user-friendly in ways you’ll appreciate every single day.Looking for a Fluke Multimeter...

    Article
  • The Borescope Adam Savage Calls "Awesome"

    YouTube star Adam Savage makes a living out of figuring out how things work. For him, getting a powerful, professional-grade borescope sent to him to try out via his Tested video series is nothing short of nirvana.“A funner toy is harder to find than a borescope or endoscope or videoscope. The idea that this camera can go into places and inspect them is thrilling!" he says exuberantly in an August 2024 session titled, “Adam Savage Sees His Workshop in a Whole New Way!""I've spent my whole life...

    Article
  • Voltage fluctuations, flicker and power quality

    Flickering lights can have an adverse effect on health, causing fatigue, lack of concentration, migraines and in some cases, epileptic shock. The severity of reaction and sensitivity varies from person to person. Some people can see a higher rate of flickering light than others. Fluorescent lamps can occasionally develop a fault that can cause them to have noticeable flicker.While health effects are a main concern, the production line of an industrial plant can also be affected. Workers can feel...

    Article
  • Tips and tools for indoor air quality and efficiency in building envelopes

    Best tools for monitoring heat loss, detecting moisture, indoor air quality and HVAC systems to improve energy efficiency in commercial buildings.

    Article
  • How to calibrate a temperature sensor in the field

    Pairing a Fluke dry well with a handheld documenting calibrator allows for a complete field temperature sensor calibration solution.

    Article
  • How to keep control valve positioners on target

    Learn how to avoid calibration drift on control valve positioners as part of your preventive maintenance program.

    Article
  • Keep those motors running: electric motor maintenance preventing downtime

    Automotive customers have zero tolerance for bad parts and therefore, electric motor maintenance needs utmost care. One of our customers, CNP Myszkow, coats small parts for the automotive industry. After dip spin painting, they heat-treat the parts in a tunnel furnace. This is divided into several areas, each with different temperatures. An electric motor drives a fan in each area to ensure stable temperatures since temperature stability relates strongly to final product quality. Any changes from...

    Article
  • Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex delivers safe, fast measurements in 1500 V dc environments

    The new meter’s thin jaw, CAT III 1500 V safety rating, and IP54 rating for dust and water make it ideal for installation and troubleshooting in solar environments.

    Article
  • Fluke introduces the only clamp meters that make non-contact voltage measurements accurately and safely without test leads

    For more information:Dan Wright(425) 446-5638dan.wright@fluke.comFluke introduces the only clamp meters that make non-contact voltage measurements accurately and safely without test leadsThe new Fluke 377 FC and 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters can measure voltage and current simultaneously without touching a live wireEVERETT, Wash., April 6, 2021 – Any time an electrician or technician makes a voltage measurement on a live conductor, there is a risk of electrical shock. The...

    Article
  • The next generation of wireless vibration monitoring is here!

    For more information:Barbara Ellis(425) 446-4949barbara.ellis@fluke.comThe next generation of wireless vibration monitoring is here!Fluke Reliability introduces the Fluke 3563 Analysis Vibration Sensor: reveal machine fault causes quickly to prevent equipment downtimeEverett, Wash., June 24, 2021 – Fluke Reliability, an operating company of Fluke Corporation, is proud to announce its newest product, the Fluke 3563 Analysis Vibration Sensor system. Vibration monitoring helps maintenance teams reduce...

    Article
  • Fluke brings its history of test and measurement leadership to the solar industry

    The new Fluke IRR1-SOL Solar Irradiance Meter makes the critical measurements needed for installing, testing, and maintaining photovoltaic systems

    Article
  • eMaint CMMS Recognized in 2020 Gartner Peer Insights Customers’ Choice for Enterprise Asset Management Software

    Everett, Washington, February 25, 2020-- Fluke Reliability today announced that its eMaint Computerized Maintenance Management System (CMMS) has been awarded the 2020 Gartner Peer Insights Customers’ Choice distinction for Enterprise Asset Management (EAM) Software. "We are honored to be recognized as a Gartner Peer Insights Customers’ Choice solution,” said Ankush Malhotra, Vice President and General Manager of Fluke Reliability. “Great customer relationships are paramount to us, so to be...

    Article
  • How to avoid buying Grey Market Fluke Tools

    When you buy from an authorized Fluke distributor or directly from Fluke, you benefit from the original manufacturer’s warranty. Learn how to protect yourself from grey market products and counterfeit Fluke tools.

    Article
  • Case Study: High-Demand Coffee Roaster Discovers Energy Savings Through Compressed Air System Testing

    Project engineers at a coffee roasting company participated in a pilot study using industrial acoustic imaging technology in a facility where conditions tend to generate many leaks. The test identified the company could save more than 10% per year in energy consumption with the new leak detection device.The 300,000-square-foot facility houses a coffee roasting and packaging area, coffee wet process area, and tea blending and packaging area. All operations require proper air pressure to efficiently...

    Article
  • The history of the multimeter

    Who invented the multimeter? From galvanometers and voltmeters to digital multimeters with thermal imaging and wireless functionality. Fluke multimeter model history.

    Article
  • Fluke 1773, 1775 and 1777 Power Quality Analyzers Software and Firmware

    .sub-title { padding-top: 10px; } .warning { padding: 0 30px; } .hr-warning { margin: 25px 0px 30px 0px; font-size: 1px; line-height: 1px; border-top: 0px solid #ffffff; border-right: 0px solid #ffffff; border-bottom: 1px solid #000000; border-bottom-color: #000000!important; border-left: 0px solid #ffffff; } Fluke Energy Analyze PlusFluke Energy Analyze Plus application software for download, analysis and reporting. Used with Fluke 1730, 1732, 1734, 1736, 1738, 1742, 1746, 1748, 1773, 1775 and...

    Article
  • How to connect a Fluke 729 Automatic Pressure Calibrator to a HART Transmitter

    In this video, we're going to show you how the Fluke 729 Automatic Pressure Calibrator connects to a HART transmitter.TranscriptMenu settingsThe first thing you do is connect up your mA jacks to the transmitter to the plus and minus. Then connect up your pressure line from the Fluke 729 to the transmitter as well. And then press the HART button.You're now on the HART pulling screen; it's trying to find the device. There are two things you need to do here.Enable that 250 ohm internal HART resistorPress...

    Article
  • Who is responsible for electrical safety in the workplace?

    Anyone who works with electrical or electromechanical equipment knows that safety is important. But defining specifically how to achieve a safe work environment requires a broader perspective. There are all kinds of rules and standards governing best practices in the workplace that professionals must learn and follow. And there are standards for the tools used by those professionals to do their job. But when it comes right down to it, where does the buck stop when it comes to safety?To heat the newest...

    Article
  • Fluke Premium Care Terms and Conditions

    Fluke Premium Care coverage begins upon date of purchase from Distributor in case of stand-alone FPC and upon activation by end user for the bundled FPC. Equipment that has been modified or abused will not be covered by Fluke Premium Care. Damaged accessories must be evaluated by Fluke Technical Support before replacement. Replacements are limited to one replacement per accessory per membership year. Fluke Premium Care is non-transferrable to a new owner of the covered hardware or to another hardware....

    Article
  • Fluke Premium Care Frequently Asked Questions (FAQs)

    Q. What Fluke products are eligible for Premium Care?A. The products listed below are the only products eligible for Premium Care currently, although we are working on adding more products.Fluke SMFT-1000 PV Analyzer I-V Curve Tracer KitFluke ii900 Industrial Acoustic ImagerFluke ii910 Precision Acoustic ImagerFluke 1773, 1775, and 1777 Power Quality AnalyzersFluke 1732, 1734, 1736, and 1738 Power Quality LoggersFluke MDA-550 Series III Motor Driver AnalyzerFluke ScopeMeter® 190 Series III (190-062,...

    Article
  • Important Safety Notice regarding Fluke 8x V Series Digital Multi-meters

    Dear Fluke Customer,Fluke Corporation has identified a potential safety issue affecting certain Fluke 83V, 87V and 88V Digital Multimeters (‘Fluke 8x V series DMMs’).As a precautionary measure, Fluke has decided to alert customers to the potential safety issue, and request that users perform a simple check to verify the unit is not impacted by the safety issue.ISSUE DESCRIPTION:Fluke 8x V series DMMs in the following serial number range may have plastic material intrusion in the COM input terminal....

    Article
  • WinFlash Free Utility

    WinFlash Free Utility (.exe)Additional Downloads: WinFlash64™ 2.20 (64bit OS) (.exe)PC BasedFree Utilities - WinFlash™TITLEVERUSE WITHWinFlash™2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTWinFlash64™(64bit OS)2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTDescriptionFirmware upgrade utility. This program...

    Article
  • PPC4 v1.2.6.14 Embedded Software

    PPC4 v1.2.6.14 Embedded Software (.bin)TITLEVERUSE WITHPPC4™1.2.6.14PPC4 (including -AF models)Instructions:Download the file by clicking on "PPC4 v1.2.6.14.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    Article
  • PPC4E v1.2.6.15 Embedded Software

    PPC4E v1.2.6.15 Embedded Software (.bin)TITLEVERUSE WITHPPC4E™1.2.6.15PPC4EInstructions:Download the file by clicking on "PPC4E v1.2.6.15.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it...

    Article
  • PPCH 1.01n Embedded Software

    PPCH 1.01n Embedded Software (.bin)TITLEVERUSE WITHPPCH™1.01n2013.07.22PPCHInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.The...

    Article
  • PPCH-G v1.02f Embedded Software

    PPCH-G v1.02f Embedded Software (.bin)TITLEVERUSE WITHPPCH-G™1.02f2012.04.04PPCH-GInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded...

    Article
  • PPCH-G v1.02k Embedded Software

    PPCH-G v1.02k Embedded Software (.bin)TITLEVERUSE WITHPPCH-G™1.02k2023.11.08PPCH-GInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded...

    Article