Fluke 353 True RMS 2000 A Clamp Meter

Fluke 353 True RMS 2000 A Clamp Meter is rated 5.0 out of 5 by 1.
  • y_2024, m_11, d_19, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_3739300757556, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 172.25ms
  • REVIEWS, PRODUCT
  • Fluke 353 True RMS 2000 A Clamp Meter
  • Fluke 353 True RMS 2000 A Clamp Meter
  • Fluke 353 True RMS 2000 A Clamp Meter
  • Fluke 353 True RMS 2000 A Clamp Meter
Discontinued

Key features

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
This product is discontinued or reclassified

Product overview: Fluke 353 True RMS 2000 A Clamp Meter

Versatile and rugged tool for applications with high currents

Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.

What's in the box:

  • 353 2000 A Clamp Meter
  • C43 Soft Carrying Case
  • 6 AA batteries (Installed)
  • Quick Reference Guide

Specifications: Fluke 353 True RMS 2000 A Clamp Meter

Electrical Specifications
Current measurement DC and AC 10 Hz to 100 HzRange40 A / 400 A / 2000 A / 1400 AC RMS
Resolution10 mA / 100 mA / 1 A
AccuracyA: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz)Range40 A / 400 A / 2000 A / 1400 AC RMS
Crest Factor12 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHzRange40 A / 400 A / 2000 A; 1400 AC RMS
Resolution10 mA / 100 mA / 1 A
Accuracy10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits
Trigger level for Inrush0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON0.50 A / 2.5 A / 8 A
Frequency measurementMeasurement range5.0 Hz to 1 kHz
Resolution0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz0.2% + 2 counts
Accuracy – 100.1 Hz to 1 kHz0.5% + 5 counts
Trigger levelRefer to current and voltage tables
1. Add 2% to error spec for CF > 2
General Specifications
BatteriesSix 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)100 hours
Test leadsRated to 1000 V
Weight.814 kg (1.8 lb)
Jaw size58 mm (2.28 in)
Dimensions (L x W x D)300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety ratingIEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature32°F to +122°F (0°C to +50°C)
Storage temperature-4°F to 140°F (-20°C to +60°C)
Operating humidity0 to 95% (non-condensing)
Operating altitude2000 m
Storage altitude10,000 m
IP rating42 (indoor use only)
Drop test requirements1 m
EMI, RFI, EMCFCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficientsCurrent0.1% of reading per °C outside 22°C to 24°C
Voltage0.1% of reading per °C outside 22°C to 24°C

Models: Fluke 353 True RMS 2000 A Clamp Meter

Fluke 353
Fluke 353 True RMS 2000 A Clamp Meter

Includes:

  • 353 clamp meter
  • C43 Soft carrying case
  • 6 AA batteries
  • User manual
  • 3 year warranty

Is there a performance verification procedure for the Fluke 353?

Asked by: Tom Honig
Hello, we are not publishing a verification procedure. The only way to have the Fluke 353 True RMS 2000 A Clamp Meter verified is to send the meter into the Fluke Service Center. Please call 1-888-993-5853 to get in touch with the Fluke Service Center. 
Answered by: FlukeCorp
Date published: 2023-08-10
  • y_2024, m_11, d_19, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_3739300757556, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 197.14ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from welding inspector helper Makes for quick check of welders equipment and like the ruggedness for field use.
Date published: 2016-12-08
  • y_2024, m_11, d_19, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_3739300757556, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 98.8ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.