5820A Oscilloscope Calibrator
Product overview: 5820A Oscilloscope Calibrator
Priority Gold Instrument CarePlan
Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan
A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.
The dedicated calibration solution for workloads to 600 MHz and beyond
In many calibration and service applications, a dedicated tool is often the best match to your workload. It allows you to purchase exactly the functionality you need to do the job without having to buy capabilities you don't need.
The 5820A is designed for just that situation, where the bulk of your workload consists of oscilloscopes, either in-lab or on-site. It's designed to calibrate all the ranges of functions of the vast majority of digital and analog oscilloscopes in use or being purchased today.
Portable and rugged enough for on-site applications
The 5820A is compact, portable and rugged. On the bench, its small footprint leaves you plenty of workspace. Outside the lab, it's easy to carry, without the need for extra accessories like pulse heads.
Five-channel option for fast automated calibrations
For automated applications, the five-channel option allows you to calibrate up to four oscilloscope channels, with trigger, simultaneously without changing cables. This allows you to perform fast, hands-free automated calibrations with documented procedures and results while freeing the operator to complete other work - a dramatic productivity improvement. Plus, the external trigger allows you to work with tough-to-capture signals like fast edges simultaneously.
Calibrate oscilloscopes to 2.1 GHz
The standard 5820A is designed to calibrate the bulk of your oscilloscope calibration workload - everything up to 600 MHz. Its bandwidth extension option lets you extend that capability still further - to oscilloscopes with bandwidths up to 2.1 GHz. The option can be purchased installed in a new 5820A, or it can be added later as your workload demands it. Either way, you purchase exactly what you need today, with the flexibility to adapt as your needs change.
Auxiliary feed-through channel and external frequency reference
Additional features include an auxiliary feed-through channel that lets you work with external generators up to 2.4 GHz. And there's an external frequency reference input that allows you to enhance the 5820A's frequency accuracy by locking it to an external 10 MHz reference.
Complete oscilloscope verification
The 5820A calibrator provides you with all the functions required to fully verify the performance of any oscilloscope with a bandwidth up to 600 MHz, checking amplitude, time, and bandwidth. The 5820A is available with an option to extend that capability to 2.1 GHz.
Amplitude (vertical deflection)
verifies the performance of all the deflection-related circuitry for amplitude accuracy in each range, using dc or square wave signals.
Fast Edge (dynamic response)
verifies the vertical amplifiers, attenuators, analog-to-digital converters in DSOs, and all other vertical deflection circuitry for transient response. The 5820A's standard £ 300 ps fast edge is more than adequate for most oscilloscopes up to 1 GHz. The 5820A-GHz option provides a £ 150 ps edge for scopes up to 2.1 GHz.
Time Marks (horizontal timing)
verify frequency, accuracy and linearity with a ± 0.33 ppm accuracy, more than enough to calibrate the most demanding digital oscilloscopes. Pulsed sawtooth, square and 20% pulse wave forms are provided. The 5820A also supports the use of an extended frequency reference for even higher frequency accuracy.
Leveled Sine Wave (bandwidth verification)
a 50 kHz to 600 MHz leveled sine wave source (extendible to 2.1 GHz with option) with excellent flatness and amplitude accuracy determines the 3 dB roll-off point of the oscilloscope and detect other discontinuities and drop outs.
Specifications: 5820A Oscilloscope Calibrator
5820A Mainframe Specifications | |
Voltage DC | Range: 0 to ±6.6V (50O) Range: ±0.25% |
Range: 0 to ±130V (1 MO) Best 1 Year Specification: ±0.025% | |
Voltage AC (Squarewave) | |
Range: : 0 to ±6.6V (50Ω) Best 1 Year Specification: ±0.25% | |
Range ±1 mV to ±130V p-p (1 MΩ) Best 1 Year Specification: ±0.05% | |
Fast Edge | Range: 4 mV to 2.5V p-p (50Ω) Best 1 Year Specification (std mainframe): : £ 300 ps Rise Time Best 1 Year Specificationwith (5820A-GHz): £ 150 ps Rise Time |
Leveled Sinewave | Range: 50 kHz to 2.1 GHz (with option) Best 1 Year Specification(std Mainframe): 50 kHz to 600 MHz ±1.5% Flatness Best 1 Year Specification (5820A-GHz option): 600 MHz to 2.1 GHz ±5% Flatness |
Time Markers | Range: 5s to 500 ps Spike, square, 20% pulse, sine Best 1 Year Specification: ±1 ppm |
Wave Generator | Range: Range: 1.8 mV to 55V p-p (1 MΩ) 1.8 mV to 2.5V p-p (50Ω) 0.01 Hz to 100 kHz Square, Sine, Triangle Best 1 Year Specification: ±3 |
Pulse Generator | |
Range: 15 mV to 1.5V amplitude Best 1 Year Specification: ±5% | |
Range: 1 ns to 500 ns width 20 ms to 200 ns period Best 1 Year Specification: ±0.33 ppm | |
DC Voltage Measurement | Range: 0 to ±6.6V Best 1 Year Specification: ±0.05% |
Current DC | Range: ±100 mA to ±100 mA Best 1 Year Specification: ± 0.25% |
Current AC | Range: 100 mA p-p to 100 mA p-p 10 Hz to 100 kHz Squarewave Best 1 Year Specification: ±0.25% |
TV Trigger | NTSC, SECAM, PAL, PAL-M |
Input Impedance Measurement | |
Range: 40Ω to 1.5 MΩ Best 1 Year Specification: ±0.1% | |
Range: 5 pF to 50 pF Best 1 Year Specification: ±5% | |
Overload Measurement | 5V to 9V (dc or ac squarewave), 5 to 60 seconds |
General Specifications | |
Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
Settling Time | 5 seconds or faster for all functions and ranges |
Standard Interfaces | IEEE-488 (GPIB), RS-232 |
Temperature Performance | Operating: 0oC to 50oC Calibration (tcal): 15oC to 35oC Storage: -20oC to 70oC |
Electromagnetic Compatibility | Designed to operate in Standard Laboratory environments where the Electromagnetic environment is highly controlled. If used in areas with Electromagnetic fields > 1 V/m, there could be errors in output values. |
Temperature Coefficient | Temperature Coefficient for temperatures outside tcal±5°C: Add 0.1 x 1-year specification/°C. |
Relative Humidity | Operating: < 80% to 30 oC, < 70% to 40 oC, < 40% to 50 oC Storage: < 95%, non-condensing |
Altitude | Non-operating: 12,200m (40,000 ft) maximum Operating: 3,050m (10,000 ft) maximum |
Safety | Designed to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010, 1-92 |
Analog Low Isolation | 20V |
EMC | Complies with EN 61326-1 |
Line Power | Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: ± 10% about line voltage setting |
Power Consumption | Consumption 250VA |
Dimensions | Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit Width: 43.2 cm (17 in), standard rack width Depth: 47.3 cm (18.6 in) overall |
Weight | 20 kg (44 lb) |
Models: 5820A Oscilloscope Calibrator
Feed Through Termination, 3W, 50 Ohm